Handle displacement and operator responses to pneumatic nutrunner torque buildup.

The objective of this study is to investigate the workstation and tool effects on the responses of the powered hand tool operator reacting against the impulsive reaction forces that may be associated with upper extremity musculoskeletal disorders. The study demonstrated a means of direct measurement of force at the interface between the tool and the operator. Fifteen experienced male operators performed three independent work configurations: pistol grip and right angle tools used on the horizontal surface and pistol grip tools used on the vertical surface, in the laboratory. A full factorial experiment consisting of 36 conditions was designed to examine the effects of working height, distance, tool, and fastener joint hardness on handle displacement and grip forces. The results indicate that operator responses were affected by different factors depending on the work configuration. When pistol grip tools were used on the vertical surface, the mean handle displacement decreased from 9.9 degrees to 7.3 degrees as the working height increased from 30 cm below shoulder to 30 cm above shoulder. When right angle tools were used, the greatest handle displacement (51.1mm) and grip force (84.7% MVC) during torque reactions were measured at 30 cm below elbow and 40% forward reach away from the operator. This study provides quantitative information that can be used for workstation design and tool selection to reduce the torque reaction experienced by powered nutrunner operators.

Adult↗

Ergonomics applications of a mechanical model of the human operator in power hand tool operation.

Applications of a new model for predicting power threaded-fastener-driving tool operator response and capacity to react against impulsive torque reaction forces are explored for use in tool selection and ergonomic workplace design. The model is based on a mechanical analog of the human operator, with parameters dependent on work location (horizontal and vertical distances); work orientation (horizontal and vertical); and tool shape (in-line, pistol grip, and right angle); and is stratified by gender. This model enables prediction of group means and variances of handle displacement and force for a given tool configuration. Response percentiles can be ascertained for specific tool operations. For example, a sample pistol grip nutrunner used on a horizontal surface at 30 cm in front of the ankles and 140 cm above the floor results in a predicted mean handle reaction displacement of 39.0 (SD=28.1) mm for males. Consequently 63%of the male users exceed a 30 mm handle displacement limit. When a right angle tool of similar torque output is used instead, the model predicted that only 4.6%of the male tool users exceed a 30 mm handle displacement. A method is described for interpolating individual subject model parameters at any given work location using linear combinations in relation to the range of modeled factors. Additional examples pertinent to ergonomic workstation design and tool selection are provided to demonstrate how the model can be used to aid tool selection and workstation design.

Adult↗

Forces associated with pneumatic power screwdriver operation: statics and dynamics.

The statics and dynamics of pneumatic power screwdriver operation were investigated in the context of predicting forces acting against the human operator. A static force model is described in the paper, based on tool geometry, mass, orientation in space, feed force, torque build up, and stall torque. Three common power hand tool shapes are considered, including pistol grip, right angle, and in-line. The static model estimates handle force needed to support a power nutrunner when it acts against the tightened fastener with a constant torque. A system of equations for static force and moment equilibrium conditions are established, and the resultant handle force (resolved in orthogonal directions) is calculated in matrix form. A dynamic model is formulated to describe pneumatic motor torque build-up characteristics dependent on threaded fastener joint hardness. Six pneumatic tools were tested to validate the deterministic model. The average torque prediction error was 6.6% (SD = 5.4%) and the average handle force prediction error was 6.7% (SD = 6.4%) for a medium-soft threaded fastener joint. The average torque prediction error was 5.2% (SD = 5.3%) and the average handle force prediction error was 3.6% (SD = 3.2%) for a hard threaded fastener joint. Use of these equations for estimating handle forces based on passive mechanical elements representing the human operator is also described. These models together should be useful for considering tool handle force in the selection and design of power screwdrivers, particularly for minimizing handle forces in the prevention of injuries and work related musculoskeletal disorders.

Biomechanical Phenomena↗

A single-degree-of-freedom dynamic model predicts the range of human responses to impulsive forces produced by power hand tools.

The human operator is modelled as a single-degree-of-freedom dynamic mechanical system for predicting the response to impulsive torque reaction forces produced by rotating spindle power hand tools such as nutrunners or screwdrivers. The model uses mass, spring and damping elements to represent the standing operator supporting the tool in the hand. It was hypothesized that these mechanical elements are affected by work location and vary among individuals. These elements were ascertained by measuring the resulting frequency and amplitude of a freely oscillating defined mechanical system when externally loaded using maximal effort to oppose its motion. Twenty-five subjects (13 female, 12 male) participated in the full factorial experiment that measured the effects of gender, vertical and horizontal work location for various tool shapes (in-line, pistol, right angle), and orientations (horizontal and vertical). The mean operator stiffness decreased from 1721 to 1195 N/m when the horizontal work location increased from 30 to 90 cm in front of the ankles for a pistol-grip handle used on a vertical surface. Males had greater mass moment of inertia of (0.0099 kg m2) than females (0.0072 kg m2) for an in-line handle used on a horizontal surface. Internal validation by independently measuring apparatus torque found that the model satisfactorily explained the measured operator dynamics with an average error of 2.86%. Group variance reflects the range of operator capacities to react against power hand tool generated forces for the sample group and therefore it may also be useful for understanding the range of capacities among a group of operators performing similar tasks.

Adult↗

Handle dynamics predictions for selected power hand tool applications.

This study uses a previously developed single-degree-of-freedom mechanical model to predict the power hand tool operator handle kinematic response to impulsive reaction forces (Lin, 2001). The model considers the human operator as a lumped parameter passive mechanical system, consisting of stiffness, mass moment of inertia, and viscous damping elements. Six power nutrunners were operated by 9 volunteers (3 men, 6 women) in the laboratory, and corresponding handle kinematics were compared against model predictions. A full-factorial experiment considered torque buildup time and work location. Normalized forearm flexor EMG was measured to quantify muscle exertions and used to proportionally adjust the stiffness parameter. The measured handle displacement for actual tool operation strongly correlated to the model predictions (R = .98) for all handle configurations. The overall model prediction error was 3% for predicting tool handle responses to impulsive reaction forces for various tool and workstation parameters. This model should make it possible for designers to identify conditions that minimize the torque reaction experienced by power hand tool operators.

Arm↗