Enhanced sensitivity in flow injection analysis using a long pathlength liquid waveguide capillary flow cell for spectrophotometric detection.

Incorporation of a liquid waveguide capillary flow cell into a flow injection instrument enhances the sensitivity of flow injection analysis with spectrophotometric detection by two orders of magnitude. Nitrite determination at nM levels has been used to demonstrate the feasibility of this novel technique for trace analysis. Combining the long pathlength spectrophotometry with flow injection analysis, this technique has advantages of low detection limit, good precision and high sample throughput.

Capillary Action↗

Automated analysis of nanomolar concentrations of phosphate in natural waters with liquid waveguide.

Concentrations of phosphate in natural waters are often below the detection limits of conventional nutrient autoanalyzers, by either gas-segmented continuous-flow analysis orflow injection analysis. A liquid waveguide capillary flow cell has been used to extend the sensitivity of a conventional autoanalyzer for the automated analysis of nanomolar concentrations of phosphate in natural waters. Total reflection of light can be achieved within the liquid core of the flow cell because the refractive index of a cell wall coated with Teflon 1600 is lower than that of water. This property allows the manufacturers to construct long liquid waveguide capillary flow cells in a helical, rather than a linear shape, with compact dimensions. A small sample volume is required because the internal volume of a 2-m long capillary flow cell is only approximately 0.5 cm3. Adaptation of this long flow cell to autoanalyzers significantly enhances the sensitivity of automated colorimetric analysis of phosphate with a molybdenum blue method, allowing for the accurate and precise determination of nanomolar concentrations of phosphate in natural waters. The advantages of this technique are a low detection limit (0.5 nM), a small sample volume (2 mL), high precision (2% at 10 nM levels), and automation for the rapid analysis of a large number of samples.

Automation↗

Long-term storage of natural water samples for dissolved oxygen determination.

A method for preserving natural water samples for dissolved oxygen analysis is recommended. The conventional method of using greased glass stoppers have been found to cause an increase in oxygen concentration by 12% over 1-month period as a result of evaporation of water sample through micro-gaps and concurrent intrusion of air into the water sample bottles. Sealing the sample bottles with water has been found to be the optimal storage method. It permits a 100.2 +/- 0.3% recovery of dissolved oxygen concentration from storage seawater samples over 4 months.