Generating correlated data for omics simulation.

Simulation of realistic omics data is a key input for benchmarking studies that help users obtain optimal computational pipelines. Omics data involves large numbers of measured features on each sample and these measures are generally correlated with each other. However, simulation too often ignores these correlations, perhaps due to computational and statistical hurdles of doing so. To alleviate this, we describe three approaches for generating omics-scale data with correlated measures which mimic real datasets. These approaches are all based on a Gaussian copula approach with a covariance matrix that decomposes into a diagonal part and a low-rank part. This decomposition allows for extremely efficient simulation, overcoming a hurdle for adoption of past methods. We use these approaches to demonstrate the importance of including correlation in two benchmarking applications. First, we show that variance of results from the popular DESeq2 method increases when dependence is included. Second, we demonstrate that CYCLOPS, a method for inferring circadian time of collection from transcriptomics, improves in performance when given gene-gene dependencies in some circumstances. We provide an R package, dependentsimr, that has efficient implementations of these methods and can generate dependent data with arbitrary marginal distributions, including discrete (binary, ordered categorical, Poisson, negative binomial), continuous (normal), or with an empirical distribution.

Computer Simulation↗

Self-contained, fully integrated biochip for sample preparation, polymerase chain reaction amplification, and DNA microarray detection.

A fully integrated biochip device that consists of microfluidic mixers, valves, pumps, channels, chambers, heaters, and DNA microarray sensors was developed to perform DNA analysis of complex biological sample solutions. Sample preparation (including magnetic bead-based cell capture, cell preconcentration and purification, and cell lysis), polymerase chain reaction, DNA hybridization, and electrochemical detection were performed in this fully automated and miniature device. Cavitation microstreaming was implemented to enhance target cell capture from whole blood samples using immunomagnetic beads and accelerate DNA hybridization reaction. Thermally actuated paraffin-based microvalves were developed to regulate flows. Electrochemical pumps and thermopneumatic pumps were integrated on the chip to provide pumping of liquid solutions. The device is completely self-contained: no external pressure sources, fluid storage, mechanical pumps, or valves are necessary for fluid manipulation, thus eliminating possible sample contamination and simplifying device operation. Pathogenic bacteria detection from approximately milliliters of whole blood samples and single-nucleotide polymorphism analysis directly from diluted blood were demonstrated. The device provides a cost-effective solution to direct sample-to-answer genetic analysis and thus has a potential impact in the fields of point-of-care genetic analysis, environmental testing, and biological warfare agent detection.

Animals↗

Hybridization enhancement using cavitation microstreaming.

Conventional DNA microarray hybridization relies on diffusion of target to surface-bound probes, and thus is a rate-limited process. In this paper, a micromixing technique based on cavitation microstreaming principle that was developed to accelerate hybridization process is explained. Fluidic experiments showed that air bubbles resting on a solid surface and set into vibration by a sound field generated steady circulatory flows, resulting in global convection flows and, thus, rapid mixing. The time to fully mix dyed solutions in a 50-microL chamber using cavitation microstreaming was significantly reduced from hours (a pure diffusion-based mixing) to 6 s. Cavitation microstreaming was implemented to enhance DNA hybridization in both fluorescence-detection-based and electrochemical-detection-based DNA microarray chips. The former showed that cavitation microstreaming results in up to 5-fold hybridization signal enhancement with significantly improved signal uniformity, as compared to the results obtained in conventional diffusion-based biochips for a given time (2 h). Hybridization kinetics study in the electrochemical detection-based chips showed that acoustic microstreaming results in up to 5-fold kinetics acceleration. Acoustic microstreaming has many advantages over most existing techniques used for hybridization enhancement, including a simple apparatus, ease of implementation, low power consumption (approximately 2 mW), and low cost.

Acoustics↗

Plastic biochannel hybridization devices: a new concept for microfluidic DNA arrays.

Conventional DNA hybridization assay kinetics depends solely on the diffusion of target to surface-bound probes, causing long hybridization times. In this study, we examined the possibilities of accelerating the hybridization process by using microfluidic channels ("biochannels") made of polycarbonate, optionally with an integrated pump. We produced two different devices to study these effects: first, hybridization kinetics was investigated by using an eSensor electrochemical DNA detection platform allowing kinetic measurements in homogenous solution. We fabricated an integrated cartridge for the chip comprising the channel network and a micropump for the oscillation of the hybridization mixture to further overcome diffusion limitations. As a model assay, we used an assay for the detection of single-nucleotide polymorphisms in the HFE-H gene. Second, based on the biochannel approach, we constructed a plastic microfluidic chip with a network of channels for optical detection of fluorescent-labeled targets. An assay for the simultaneous detection of four pathogenic bacteria surrogate strains from multiple samples was developed for this device. We observed high initial hybridization velocities and a fast attainment of equilibrium for the biochannel with integrated pump. Experimental results were compared with predictions generated by computer simulations.

Computer Simulation↗

High sensitivity PCR assay in plastic micro reactors.

Small volume operation and rapid thermal cycling have been subjects of numerous reports in micro reactor chip development. Sensitivity aspects of the micro PCR reactor have not been studied in detail, however, despite the fact that detection of rare targets or trace genomic material from clinical and/or environmental samples has been a great challenge for microfluidic devices. In this study, a serpentine shaped thin (0.75 mm) polycarbonate plastic PCR micro reactor was designed, constructed, and tested for not only its rapid operation and efficiency, but also its detection sensitivity and specificity, in amplification of Escherichia coli (E. coli) K12-specific gene fragment. At a template concentration as low as 10 E. coli cells (equivalent to 50 fg genomic DNA), a K12-specific gene product (221 bp) was adequately amplified with a total of 30 cycles in 30 min. Sensitivity of the PCR micro reactor was demonstrated with its ability to amplify K12-specific gene from 10 cells in the presence of 2% blood. Specificity of the polycarbonate PCR micro reactor was also proven through multiplex PCR and/or amplification of different pathogen-specific genes. This is, to our knowledge, the first systematic study of assay sensitivity and specificity performed in plastic, disposable micro PCR devices.

Base Sequence↗

Bubble-induced acoustic micromixing.

A mixing technique based on the principle of bubble-induced acoustic microstreaming was developed. The mixer consists of a piezoelectric disk that is attached to a reaction chamber, which is designed in such a way that a set of air bubbles with desirable size is trapped in the solution. Fluidic experiments showed that air bubbles resting on a solid surface and set into vibration by the sound field generated steady circulatory flows, resulting in global convection flows and thus rapid mixing. The time to fully mix a 22 microL chamber is significantly reduced from hours (for a pure diffusion-based mixing) to tens of seconds. Numerical simulations showed that the induced flowfield and thus degree of mixing strongly depend on bubble positions. Optimal simulated mixing results were obtained for staggered bubble distribution that minimizes the number of internal flow stagnation regions. Immunomagnetic cell capture experiments showed that acoustic microstreaming provided efficient mixing of bacterial cell (Esherichia coli K12) matrix suspended in blood with magnetic capture beads, resulting in highly effective immunomagnetic cell capture. Bacterial viability assay experiments showed that acoustic microstreaming has a relatively low shear strain field since the blood cells and bacteria remained intact after mixing. Acoustic microstreaming has many advantages over most existing chamber micromixing techniques, including simple apparatus, ease of implementation, low power consumption (2 mW), and low cost.

Journal Article↗

DNA amplification and hybridization assays in integrated plastic monolithic devices.

PCR amplification, DNA hybridization, and a hybridization wash have been integrated in a disposable monolithic DNA device, containing all of the necessary fluidic channels and reservoirs. These integrated devices were fabricated in polycarbonate plastic material by CO2 laser machining and were assembled using a combination of thermal bonding and adhesive tape bonding. Pluronics polymer phase change valves were implemented in the devices to fulfill the valving requirements. Pluronics polymer material is PCR compatible, and 30% Pluronics polymer valves provide enough holding pressure to ensure a successful PCR amplification. By reducing the temperature locally, to approximately 5 degrees C, Pluronics valves were liquefied and easily opened. A hybridization channel was made functional by oligonucleotide deposition, using Motorola proprietary surface attachment chemistry. Reagent transport on the device was provided by syringe pumps, which were docked onto the device. Peltier thermal electrical devices powered the heating and cooling functionality of the device. Asymmetrical PCR amplification and subsequent hybridization detection of both Escherichia coli K-12 MG1655 and Enterococcus faecalis DNAE genes have been successfully demonstrated in these disposable monolithic devices.

DNA↗

Effects of protein kinase C on M-phase promoting factor in early development of fertilized mouse eggs.

The mechanism of development of mouse fertilized eggs from the one-cell stage to the two-cell stage remains unclear to date. In the present study, we have evaluated protein kinase C (PKC) and M-phase promoting factor (MPF) kinase activity in fertilized mouse eggs treated with a PKC modulator. PKC and MPF activity have similar activity. The two subunits of MPF, p34(cdc2) and cyclin B, were shown to be included in the substrates phosphorylated by PKC in fertilized mouse eggs, while PKC modulator affected the electrophoretic mobility shift of cdc2 and cdc25C by dephosphorylation and phosphorylation. These results clearly indicate that PKC may affect the progression of the cell cycle through post-translational modification of MPF activity.

Amanitins↗