PubMed Health⌕ Search

Biomedical subjects

Jianyi Xu

Publications and source records attributed to Jianyi Xu.

3 recordsLinked to original sources

Ultrasonic metamaterials with negative modulus.

The emergence of artificially designed subwavelength electromagnetic materials, denoted metamaterials, has significantly broadened the range of material responses found in nature. However, the acoustic analogue to electromagnetic metamaterials has, so far, not been investigated. We report a new class of ultrasonic metamaterials consisting of an array of subwavelength Helmholtz resonators with designed acoustic inductance and capacitance. These materials have an effective dynamic modulus with negative values near the resonance frequency. As a result, these ultrasonic metamaterials can convey acoustic waves with a group velocity antiparallel to phase velocity, as observed experimentally. On the basis of homogenized-media theory, we calculated the dispersion and transmission, which agrees well with experiments near 30 kHz. As the negative dynamic modulus leads to a richness of surface states with very large wavevectors, this new class of acoustic metamaterials may offer interesting applications, such as acoustic negative refraction and superlensing below the diffraction limit.

Journal Article↗

The Gaussian beam expansion applied to Fresnel field integrals.

A general result of the Gaussian angular-spectrum expansion is presented for computing the Fresnel field integral. The reciprocity relation of the Gaussian expansion parameters in both coordinate and angular-spectrum domains is obtained. Some examples are provided that demonstrate the usefulness of this relation.

Letter↗

Numerical simulation of the transient temperature field from an annular focused ultrasonic transducer.

Knowledge of the extent of the "heated necrosis element" from a single exposure in target tissue created by an ultrasonic beam is critical for the application of focal ultrasound (US) surgery (FUS). This study uses the O'Nell and Pennes formulas to simulate the heated necrosis element from an annular focused transducer and to examine its dependence on exposure dosage, as well as some design parameters of the transducer. Several conclusions may be drawn from our numerical results: 1. With increasing exposure, the heated necrosis element increases, but its contour becomes plumper and the influence of sound intensity I is found to be greater than that of the exposure time t. 2. To get a similar heated necrosis element, the exposure approximately satisfies a relation: It(0. 4 3)=constant. 3. Increasing the US frequency or the outer-radius of the annular transducer leads to a decrease in the heated necrosis volume.

Algorithms↗