PubMed Health⌕ Search

Biomedical subjects

Jie-Ke Cheng

Publications and source records attributed to Jie-Ke Cheng.

9 recordsLinked to original sources

Monitoring dopamine release from single living vesicles with nanoelectrodes.

Carbon fiber nanoelectrodes (tip diameter = ca. 100 nm) have been first used to monitor real-time dopamine release from single living vesicles of single rat pheochromocytoma (PC12) cells. The experiments show that active and inactive release sites exist on the surface of cells, and the spatial distributions have been differentiated even in the same active release zone. It is first demonstrated that multiple vesicles can sequentially release dopamine at the same site of the cell surface, which possibly plays the main role in the dopamine release from PC12 cells.

Action Potentials↗

Transport, location, and quantal release monitoring of single cells on a microfluidic device.

A novel microfluidic device has been developed for on-chip transport, location, and quantal release monitoring of single cells. The microfluidic device consists of a plate of PDMS containing channels for introducing cells and stimulants and a glass substrate into which a cell micro-chamber was etched. The two tightly reversibly sealed plates can be separated for respective cleaning, which significantly extends the lifetime of the microchip that is frequently clogged in cell analysis experiments. Using hydraulic pressure, single cells were transported and located on the microfluidic chip. After location of a single PC12 cell on the microfluidic chip, the cell was stimulated by nicotine that was also introduced through the micro-channels, and the quantum release of dopamine from the cell was amperometricly detected with our designed carbon fiber microelectrode. The results have demonstrated the convenience and efficiency of using the microfluidic chip for monitoring of quantal release from single cells and have offered a facile method for the analysis of single cells on microfluidic devices.

Journal Article↗

Carbon fiber nanoelectrodes modified by single-walled carbon nanotubes.

Microelectrode voltammetry has been considered to be a powerful technique for single biological cell analysis and brain research. In this paper, we have developed a simple method to get highly sensitive carbon fiber nanoelectrodes (CFNE) modified by single-walled carbon nanotubes (SWNTs) on the basis of our previous work. The electrochemical behavior of SWNTs/CFNE was characterized by potassium ferricyanide, dopamine (DA), epinephrine (E), and norepinephrine (NE) using cyclic voltammetry (CV). Compared with CFNE, SWNTs/CFNE has a much larger available internal surface area per external geometric area, which is supported by SEM images. The modified electrodes show very high sensitivity and favorable electrochemical behavior toward these neurotransmitters. The peak current increases linearly with the concentration of DA, E, and NE in the range of 1.0 x 10(-)(7)-1.0 x 10(-)(4), 3.0 x 10(-)(7)-1.0 x 10(-)(4), and 5.0 x 10(-)(7)-1.0 x 10(-)(4) M, respectively. The CV detection limit (S/N = 3) of DA, E, and NE is 7.7 x 10(-)(9), 3.8 x 10(-)(8), and 4.2 x 10(-)(8) M, respectively. The modified electrode exhibited almost the same electrochemical behavior after 15 days, indicating that SWNTs/CFNE is pretty stable and has good reproducibility.

Dopamine↗

Separation of biogenic amines by micellar electrokinetic chromatography with on-line chemiluminescence detection.

A method of on-line chemiluminescence detection with capillary electrophoresis for biogenic amines (diaminopropane, putrescine, cadaverine and diaminohexane) labeled with N-(4-aminobutyl)-N-ethylisoluminol is reported for the first time. Two separation modes, capillary zone electrophoresis and micellar electrokinetic chromatography (MEKC), were studied. The results show that excellent resolution was achieved in MEKC. Parameters affecting separation process and chemiluminescence detection have been examined in detail. Under the optimum conditions, the baseline separation of four amines was obtained within 7.5 min. The detection limits (S/N=3) of diaminopropane, putrescine, cadaverine and diaminohexane are 3.5 x 10(-8), 3.5 x 10(-8), 3.9 x 10(-8) and 1.2 x 10(-7) M, respectively. The method was applied to the analysis of biogenic amines in lake water.

Biogenic Amines↗

Elemental speciation analysis in capillary electrophoresis.

The growing awareness of the strong development of the toxicity of heavy metals upon their chemical forms has led to an increasing interest in the qualitative and quantitative determination of specific metal species. Speciation has therefore become an important topic of present-day analytical research. The development in the elemental speciation analysis by capillary electrophoresis (CE) is reviewed. Various CE separation modes and detection techniques applied are discussed. A comprehensive description of reported methods to date in CE speciation analysis including metals, metalloids and nonmetallic elements is demonstrated. Some examples are presented to demonstrate CE's ability to solve real-world speciation analysis with emphasis on the applications in biological and environmental samples. Further, some issues concerning the limitations and the future of CE with regard to speciation studies are also discussed.

Electrophoresis, Capillary↗

Ultrasensitive chemiluminescence detection in capillary electrophoresis.

Capillary electrophoresis techniques offer high plate numbers and are highly suited for the efficient separations of a wide variety of chemical components in diverse matrices. Because of the small capillary and detection cell dimensions, together with the minute volumes of samples to be injected, sensitive detection schemes based on different physicochemical principles are being developed. One logical approach to increased sensitivity in capillary electrophoresis detection has been the development of chemiluminescence-based detectors. The development of on-line ultrasensitive chemiluminescence detection (referred to the concentration detection limit of nM order of magnitude or mass detection limit of amol order of magnitude) in capillary electrophoresis system is reviewed. The applications and limitations of the current detection methodology are briefly considered and future prospects for the development are discussed.

Electrophoresis, Capillary↗

Influence of soluble polymer polyvinylpyrrolidone on separation of small peptides and amino acids by microchip-based capillary electrophoresis.

In microchip-based capillary electrophoresis, the resolution and separation efficiency of small peptides and amino acids can be noticeably improved by adding a low molecular weight (30,000) soluble polymer additive, polyvinypyrrolidone in the separation medium. Several separation conditions such as injection time and electrophoretic buffer have been investigated and optimized. Using an electro-stacking scheme, the resolution and separation efficiency of small peptides and amino acids can be enhanced significantly. Under the optimal conditions, the separation of fluorescein isothiocyanate Isomer I-labeled small peptides and amino acids was successfully achieved within 100 s.

Amino Acids↗

Microchip capillary electrophoresis with electrochemical detection.

A novel microchip capillary electrophoresis system with electrochemical detection, using the replaceable microelectrode, is first reported. This kind of electrode can be fabricated in general laboratories and can be replaced quickly with electrodes of different materials according to the requirements of experiments. The end-column electrochemical detection on microchip CE was achieved by fixing the working electrode (such as carbon fiber, Pt, or Au, etc.) through a guide tube on the end of the separation channel. The experiment results indicate that the alignment of the electrode with the channel outlet can be carried out accurately and reproducibly, and therefore, the detection device has low noise and good reproducibility. The detection limit of dopamine is 2.4 x 10(-7) M, which is the lowest result reported so far. The separation and detection of dopamine, 5-hydroxytryptamine and epinephrine using carbon fiber and Pt microdisk electrodes within 50 s was successfully performed.

Biogenic Amines↗

Highly sensitive chemiluminescence detection of copper(II) in capillary electrophoresis with field-amplified sample injection.

Field-amplified sample injection of copper(II) was investigated using capillary electrophoresis with chemiluminescence detection. The sensitivity of copper(II) has been improved markedly by the field-amplified sample injection technique and the detection limit reaches 2 x 10(-11) M. By injection of a short plug of water before sample introduction, the sensitivity can be further improved 5-fold and the detection limit reaches 4 x 10(-12) M. The relative standard deviations (n = 6) of the migration time and the peak height are 0.61% and 4.7% at 1.0 x 10(-9) M Cu(II), respectively. Parameters affecting the field-amplified sample injection, such as separation voltage and concentration of electrophoretic buffer, have been investigated.

Copper↗