PubMed Health⌕ Search

Biomedical subjects

Jih-Min Lin

Publications and source records attributed to Jih-Min Lin.

3 recordsLinked to original sources

Usefulness of single-bolus adenosine test for confirming sinus node dysfunction and correlation with atrial overdrive suppression test.

We prospectively studied 42 consecutive patients who had symptomatic sinus node dysfunction and 17 age-matched controls by measuring maximal and corrected maximal sinus node recovery times with an atrial overdrive suppression test and single-bolus adenosine administration (0.15 mg/kg). We found a positive correlation between the 2 methods, with reasonably good sensitivity, specificity, and predictive accuracy.

Adenosine↗

Use of double-potential barrier to identify functional isthmus at the cavotricuspid isthmus for facilitating catheter ablation of isthmus-dependent atrial flutter.

INTRODUCTION: The aim of the study was to identify an alternative target for more effective radiofrequency catheter ablation (RFCA) of isthmus-dependent atrial flutter (AFL). METHODS AND RESULTS: We hypothesized that a functional isthmus formed by preexisting double potential barrier at the cavotricuspid isthmus (CTI) could serve as a new target site for facilitating RFCA of AFL. Forty-three consecutive patients with recurrent isthmus-dependent AFL were studied using three-dimensional navigated magnetic mapping and ablation technique. Twenty patients (47%, group A) were shown to have a narrower functional channel at the CTI (functional isthmus). The remaining 23 patients did not have this feature (53%, group B). In group A, double potentials were clustered near the border of the inferior vena cava (IVC) of the CTI and served as a functional channel along the tricuspid annulus (TA). The interspike interval of double potentials was 87 +/- 26 ms near the IVC border and 45 +/- 17 ms (P < 0.0001) near the TA border of CTI. RFCA targeting at the functional isthmus in group A resulted in interruption of bidirectional transisthmus conduction with fewer radiofrequency pulses (6.7 +/- 4.7 in group A vs 21.1 +/- 17.1 pulses in group B, P < 0.001), shorter ablation line (11.6 +/- 4.0 mm vs 37.8 +/- 7.2 mm, P < 0.0001) with no arrhythmia recurrence. These functional isthmuses were found to be located at the lateral third of CTI in 12 patients, middle third in 7, and medial third in 1. This finding is different from that obtained by the conventional method in group B (lateral in 5, middle in 16, medial in 2, P < 0.038). CONCLUSION: In our study, a functional, rather than anatomic, isthmus formed by preexisting double-potential barrier at the CTI was identified in 47% of patients with isthmus-dependent AFL. It is a useful guide to facilitate RFCA of isthmus-dependent AFL.

Atrial Flutter↗

Predictors of clinical recurrence after successful electrical cardioversion of chronic persistent atrial fibrillation: clinical and electrophysiological observations.

Recurrence of atrial fibrillation (AF) after electrical cardioversion of chronic AF is not uncommon. However, it remains unclear which parameter(s) predict clinical recurrence. To assess the potential predictors of clinical recurrence after successful electrical cardioversion, we analyzed clinical, echocardiographic and electrophysiologic parameters in 36 patients (age 63 +/- 11 years; 26 males, 10 females) with chronic persistent AF lasting more than 3 months. The dimensions of the left atrium and left ventricular end diastole and end systole were measured by echocardiography. The P wave characteristics from the surface 12-lead electrocardiogram (ECG) were studied in sinus rhythm. Atrial local activations were studied by biatrial basket electrode mapping in AF. With a mean of 7 +/- 2 months of follow-up, 17 (47%) patients had AF recurrence despite multiple antiarrhythmic drug therapy. None of the clinical or echocardiographic parameters were relevant to the recurrence. However, among the surface ECG and intraatrial electrophysiological parameters, the mean P wave duration was the only independent predictor of the risk of clinical recurrence after successful electrical cardioversion. The sensitivity and predictive accuracy of recurrence were 82 and 70%, respectively, when the mean P wave duration was more than 125 ms.

Adult↗