PubMed Health⌕ Search

Biomedical subjects

Jilie Kong

Publications and source records attributed to Jilie Kong.

11 recordsLinked to original sources

Photoelectric performance of bacteria photosynthetic proteins entrapped on tailored mesoporous WO3-TiO2 films.

Novel three-dimensional wormlike mesoporous WO(3)-TiO(2) films with tailored pore size (approximately 7.1 nm) were applied to prepare the bio-photoelectrodes (Bio-PEs) through direct entrapping the bacteria photosynthetic reaction center (RC) proteins. These mesoporous WO(3)-TiO(2) films exhibited unique characteristics in the specific loading of RC with high activity retained. Moreover, well-matched energy levels of WO(3)-TiO(2) and RC contributed to the photoelectric performance, especially in the red to near-infrared (NIR) region, of the derived Bio-PEs. Such strategy of manipulating the Bio-PEs based on well-designed mesoporous metal oxides and RC provides an alternative system to probe the photoinduced multiple-pathway electron transfer of photosensitive chromophores, which may open a new perspective to develop versatile bio-photoelectric devices.

Adsorption↗

Controlled switchable surface.

The macroscopic properties of a surface can be intelligently controlled by alternating the states of the modified molecules, such as polymers, metallic oxide, or self-assembled monolayers (SAMs). This article reviews various approaches to create a switchable surface and different types of external stimuli used to switch the surface properties. This area is of potential benefit for biomaterials, biosensors, information storage, microfluidic systems, adhesive materials, nanolithography, and so on.

Journal Article↗

Determining the purity of samples from natural products by coupling HPLC and CCD spectrometry.

Isolation and identification of natural products is a very important and active research field. However, establishing the purity of the samples during the isolation process is quite difficult, especially when the retention times are similar for two desired components in HPLC. Although some technologies, e.g. MS and NMR, offer effective ways of obtaining purity information about the samples, the expensive instrumentation required or the off-line nature of coupling (generally speaking) make purity analysis somewhat inconvenient. In this paper, an on-line analytical system coupling HPLC and a CCD spectrometer for determination of purity for each eluate was developed in a thin layer spectrometric cell. The effectiveness of the system was demonstrated by differentiating Tanshinone I, Tanshinone IIA, and their mixture. The time-resolved UV-Vis spectra promptly revealed significant differences between the three samples while conventional single wavelength detection (CSWLD) could not. The system was then used to distinguish two steroid compounds which behaved as a single component in CSWLD. The compounds were isolated from a Chinese marine invertebrate animal, a marine annelid, Arenicola cristata, referred to here as Stimpson. The method reported here provided an efficient, convenient, fast, and inexpensive approach holding promise for on-line determination of the purity of samples isolated from natural products.

Abietanes↗

Stable microstructured network for protein patterning on a plastic microfluidic channel: strategy and characterization of on-chip enzyme microreactors.

Chemical modification of a poly(methyl methacrylate) (PMMA) microchannel surface has been explored to functionalize microfluidic chip systems. A craft copolymer was designed and synthesized to introduce the silane functional groups onto the plastic surface first. Furthermore, it has been found that, through a silicon-oxygen-silicon bridge that formed by tethering to these functional groups, a stable patterning network of gel matrix could be achieved. Thus, anchorage of proteins could be realized onto the hydrophobic PMMA microchannels with bioactivity preserved as far as possible. The protein homogeneous patterning in a microfluidic channel has been demonstrated by performing microchip capillary electrophoresis with laser-induced fluorescence detection and confocal fluorescence microscopy. To investigate the bioactivity of enzymes entrapped within stable silica gel-derived microchannels, the suggested scheme was employed to the construction of immobilized enzyme microreactor-on-a-chip. The proteolytic activity of immobilized trypsin has been demonstrated with the digestion of cytochrome c and bovine serum albumin at a fast flow rate of 4.0 microL/min, which affords the short residence time less than 5 s. The digestion products were characterized using MALDI-TOF MS with sequence coverage of 75 and 31% observed, respectively. This research exhibited a simple but effective strategy of plastic microchip surface modification for protein immobilization in biological and proteomic research.

Amino Acid Sequence↗

Hydrothermal synthesis, crystal structure, conductivity, and thermal decomposition of [Cu(4,4'-bipy)(H2O)(Mo3O10)].H2O.

The hydrothermal reaction of (NH(4))(6)Mo(7)O(24).4H(2)O, CuCl(2).2H(2)O, and 4,4'-bipyridine yields bipyridine-ligated copper-trimolybdate monohydrate [Cu(4,4'-bipy)(H(2)O)(Mo(3)O(10))].H(2)O in the monoclinic system with space group of C(2/c) and cell parameters of a = 15.335(2) A, b = 15.535(2) A, c = 15.106(2) A, beta = 101.162(2) degrees, V = 3530.7(9) A(3), and Z = 8. Its structure consists of one-dimensional infinite ([Mo3O10]2-)( infinity ) chains linked through [Cu2(H2O)2(4,4'-bipy)] units. The Mo-O chain contains distorted [MoO(6)] octahedra connected through corner-sharing oxygen atoms into infinite chains along the c direction and each chain is located in the channel formed by four adjacent crossing chains of [Cu(4,4'-bipy)(H2O)](n)(2n+). The crystal shows weak conductivity through Mo-O chain along the c direction and insulating property along either a or b direction. Furthermore, a crystalline bimetallic oxide, CuMo3O10, forms when the title compound undergoes thermal treatment in N(2) atmosphere after the complete removal of the ligands.

Copper↗

Controlled protein assembly on a switchable surface.

The strategy presented in this work supplies a general method of controlling protein assembly on a switchable low-density SAM, which may open a new way to design functional biocomposite films for biosensors or protein chips.

Protein Engineering↗

Ultrathin alumina sol-gel-derived films: allowing direct detection of the liver fibrosis markers by capacitance measurement.

A capacitive immunoassay based on antibody-embedded ultrathin gamma-alumina sol-gel films (approximately 20 to 40 nm) was successfully prepared in this work. The nanofilms greatly increased the capacitance change initiated by the recognition between the immobilized antibody and the target antigen, which allowed capacitive measurements capable of directly determining the antigen more sensitive than that of thick films. Meanwhile, the inorganic films with high permittivity significantly increased the time constant (i.e., RC value) of the films, which rendered the potentiostatic step method with acceptable S/N ratio. These two advantages enabled the immunosensor to be readily employed in a multichannel capacitance analysis system. An eight-channel hIgG capacitive sol-gel-derived immunoassay based on this system was constructed to illustrate the application. Compared with the detection limits of SiO2 sol-gel-derived hIgG capacitive immunosensors or the conventional ELISA immunoassay, the immunoassay based on thin alumina gel film showed a lower detection limit of 1 ng mL(-1). The novel immunoassay was employed to co-determine two liver fibrosis markers (hyaluronan and laminin) in mixed samples from approximately 0.5 to 50 ng mL(-1). The little derivation caused by the interfered antigen indicated that the sensitive, specific, low-cost sol-gel-derived multichannel immunosensors might be a promising approach in the application of screening disease markers.

Aluminum Oxide↗

Covalently coupling the antibody on an amine-self-assembled gold surface to probe hyaluronan-binding protein with capacitance measurement.

Hyaluronan-binding proteins (HABPs), the important structural components of extracellular matrices, served important structural and regulatory functions during development and in maintaining adult tissue homestats. A sensitive, specific and rapid-responsing immunosensor to probe hyaluronan-binding cartilage protein was presented in this work. The novel immunosensor supplied a label-free detection method for HABP, which was based on measuring the capacitance change in-between the unlabeled HABP (antigen) and rabbit-anti-HABP (Ra-HABP, antibody). The HABP immunosensor was prepared by covalently coupling Ra-HABP on an amine-self-assembled gold surface with glutaraldehyde. The capacitance change corresponding to the concentration of HABP, the target antigen, was evaluated by an electrochemical approach called potentiostatic-step in microseconds. The immunosensor showed a specific response to HABP in the range 10-1000 ng/ml. The presented work supplied a promising clinical screening method.

Adsorption↗

TiO2 sol-gel derived amperometric biosensor for H2O2 on the electropolymerized phenazine methosulfate modified electrode.

A novel hydrogen peroxide biosensor was developed based on the immobilization of horseradish peroxidase (HRP) in a TiO(2) sol-gel matrix on an electropolymerized phenazine methosulfate (PMS) modified electrode surface. Such membranes are of interest due to their high surface area, biological compatibility, and ease of fabrication. HRP entrapped in the TiO(2) matix was stable and retained its activity to a large extent. Cyclic voltammetry and amperometric measurements were employed to demonstrate the feasibility of electron transfer between immobilized HRP and the glassy carbon electrode via electropolymerized PMS. The influence of various experimental parameters such as operating potential, pH, temperature, and stability was investigated for optimum analytical performance. The biosensor provided a wide linear calibration range from 4.0x10(-6) M to 1.0x10(-3) M, with a detection limit of 8.0x10(-7) M at a signal-to-noise ratio of 3. The sensor retained 80% of its original activity after two months of operation.

Biosensing Techniques↗

A BOD biosensor based on a microorganism immobilized on an Al2O3 sol-gel matrix.

A novel BOD biosensor has been fabricated from a microbial membrane on an oxygen electrode; a porous inorganic Al2O3 sol-gel matrix was used to immobilize the yeast. Use of the sensor is convenient and rapid compared with the official BOD5 method. The gelation time required to form the microorganism membrane was less than 15 min. There was linear relationship between the response (sensor current) and BOD values ranging from 10-50 mg x L(-1). The lifetime of the BOD biosensor was more than 30 days at ambient temperature.

Aluminum Oxide↗

Differentiating the orientations of photosynthetic reaction centers on Au electrodes linked by different bifunctional reagents.

The photosynthetic reaction center (RC) composite film was fabricated by self-assembled monolayers (SAMs) on the Au electrode with two different bifunctional reagents, 4-aminothiophenol (ATP) and 2-mercaptoethylamine (MEA), respectively. The square wave voltametry (SWV), bulk electrolysis and photocurrent test were employed for characterizing the composite film. The dramatic different electrochemical characteristics were observed for the two types of films, which strongly suggested an orientational difference for RC arising from the structural difference between the two bifunctional reagents. For RC-MEA film, three redox peaks which implying electron transfer (ET) between the primary donor (P) and the bacteriopheophytin (Bphe) were observed. While for RC-ATP film, two redox peaks implying ET between the nonheme iron and the primary quinone (Q(A)) were observed. The ET behavior driven by electric field also supported the result that the RC could be linked to the electrode at different sites. The site-specific immobilization approach reported here supplies a method to differentiate the protein orientation.

Aniline Compounds↗