PubMed Health⌕ Search

Biomedical subjects

Jilin Yan

Publications and source records attributed to Jilin Yan.

12 recordsLinked to original sources

Microchip capillary electrophoresis with solid-state electrochemiluminescence detector.

We report microchip capillary electrophoresis (CE) coupling to a solid-state electrochemiluminescence (ECL) detector. The solid-state ECL detector was fabricated by immobilizing tris(2,2'-bipyridyl)ruthenium(II) (TBR) into an Eastman AQ55D-silica-carbon nanotube composite thin film on an indium tin oxide (ITO) electrode. After being made by a photolithographic method, the surface of the ITO electrode was coated with a thin composite film through a micromolding in capillary (MIMIC) technique using a poly(dimethylsiloxane) (PDMS) microchannel with the same pattern as an ITO electrode. Then the TBR was immobilized via ion exchange by immersing the ITO electrode containing the thin film in TBR aqueous solution. The whole system was built by reversibly sealing the TBR-modified ITO electrode plate with a PDMS layer containing electrophoresis microchannels. The results indicated that the present solid-state ECL detector displayed good durability and stability in the microchip CE-ECL system. Proline was selected to perform the microchip device with a limit of detection of 2 microM (S/N=3) and a linear range from 25 to 1000 microM. Compared with the CE-ECL of TBR in aqueous solution, while the CE microchip with solid-state ECL detector system gave the same sensitivity of analysis, a much lower TBR consumption and a high integration of the whole system were obtained. The present system was also used for medicine analysis.

9,10-Dimethyl-1,2-benzanthracene↗

Fabrication of a poly(dimethylsiloxane)-based electrochemiluminescence detection cell for capillary electrophoresis.

An easy but effective technique is described here for quick fabrication of low-cost electrochemiluminescence detection cells for capillary electrophoresis. The technique is based on molding of poly(dimethylsiloxane) (PDMS) with a capillary column inserted into a pipet tip. Two access holes are left in the PDMS slab; they provide neat accommodations for the separation capillary and the working electrode made with the same type of tip. Since the access holes are well-aligned, the electrode and the capillary are automatically aligned; thus, end-column detection is easily obtained. Fabrication of the detection cell is straightforward; no micromechanical operation is included. Also the principle for the procedure makes it possible to efficiently batch production detection cells with good reproducibility. Because of the end-column scheme, the cell can be adopted for electrophoresis with electrochemical detection as well.

Journal Article↗

Simultaneous electrochemical and electrochemiluminescence detection for microchip and conventional capillary electrophoresis.

A simultaneous electrochemical (EC) and electrochemiluminescence (ECL) detection scheme was introduced to both microchip and conventional capillary electrophoresis (CE). In this dual detection scheme, tris(2,2'-bipyridyl)ruthenium(II) (Ru(bpy)3(2+)) was used as an ECL reagent as well as a catalyst (in the formation of Ru(bpy)3(3+)) for the EC detection. In the Ru(bpy)3(2+)-ECL process, Ru(bpy)3(3+) was generated and then reacted with analytes resulting in an ECL emission and a great current enhancement in EC detection due to the catalysis of Ru(bpy)3(3+). The current response and ECL signals were monitored simultaneously. In the experiments, dopamine and three kinds of pharmaceuticals, anisodamine, ofloxacin, and lidocaine, were selected to validate this dual detection strategy. Typically, for the EC detection of dopamine with the presence of Ru(bpy)3(2+), a approximately 5 times higher signal-to-noise ratio (S/N) can be achieved than that without Ru(bpy)3(2+), during the simultaneous EC and ECL detection of a mixture of dopamine and lidocaine using CE separation. The results indicated that this dual EC and ECL detection strategy could provide a simple and convenient detection method for analysis of more kinds of analytes in CE separation than the single EC or ECL detection alone, and more information of analytes could be achieved in analytical applications simultaneously.

Electrochemistry↗

Electrochemiluminescence detection with integrated indium tin oxide electrode on electrophoretic microchip for direct bioanalysis of lincomycin in the urine.

In this article, an antibiotic, lincomycin was determined in the urine sample by microchip capillary electrophoresis (CE) with integrated indium tin oxide (ITO) working electrode based on electrochemiluminescence (ECL) detection. This microchip CE-ECL system can be used for the rapid analysis of lincomycin within 40s. Under the optimized conditions, the linear range was obtained from 5 to 100 microM with correlation coefficient of 0.998. The limit of detection (LOD) of 3.1 microM was obtained for lincomycin in the standard solution. We also applied this method to analyzing lincomycin in the urine matrix. The limit of detection of 9.0 microM was obtained. This method can determine lincomycin in the urine sample without pretreatment, which demonstrated that it is a promising method of detection of lincomycin in clinical and pharmaceutical area.

Anti-Bacterial Agents↗

Capillary electrophoresis coupled with electrochemiluminescence detection using porous etched joint.

A new setup to couple capillary electrophoresis (CE) with electrochemiluminescence (ECL) detection is described in which the electrical connection of CE is achieved through a porous section at a distance of 7 mm from the CE capillary outlet. Because the porous capillary wall allowed the CE current to pass through and there was no electric field gradient beyond that section, the influence of CE high-voltage field on the ECL procedure was eliminated. The porous section formed by etching the capillary with hydrofluoric acid after only one side of the circumference of 2-3 mm of polyimide coating of the capillary was removed, while keeping the polyimide coating on the other part to protect the capillary from HF etching makes the capillary joint much more robust since only a part of the circumference of it is etched. A standard three-electrode configuration was used in experiments with Pt wire as a counter electrode, Ag/AgCl as a reference electrode, and a 300-microm diameter Pt disk as a working electrode. Compared with CE-ECL conventional decoupler designs, the present setup with a porous joint has no added dead volume created. Moreover, the dead volume can be increasingly decreased by shortening the distance ( approximately 100 microm) between the working electrode and the end of the separation capillary. The versatility in choice of capillaries and separation buffers within this design is the main advantage over the use of small i.d. capillary and low conductivity buffer in some CE-ECL systems. The performance of this setup is illustrated by the analyses of tripropylamine and proline.

Electrophoresis, Capillary↗

Drug-human serum albumin binding studied by capillary electrophoresis with electrochemiluminescence detection.

A new technique for investigating drug-protein binding was developed employing capillary electrophoresis (CE) coupled with tris(2,2'-bipyridyl) ruthenium(II) [Ru(bpy)(3) (2+)] electrochemiluminescence (ECL) (CE-ECL) detection after equilibrium dialysis. Three basic drugs, namely pridinol, procyclidine and its analogue trihexyphenidyl, were successfully separated by capillary zone electrophoresis with end-column Ru(bpy)(3) (2+) ECL detection. The relative drug binding to human serum albumin (HSA) for each single drug as well as for the three drugs binding simultaneously was calculated. It was found that the three antiparkinsonian drugs compete for the same binding site on HSA. This work demonstrated that Ru(bpy)(3) (2+) CE-ECL can be a suitable technique for studying drug-protein binding.

Antiparkinson Agents↗

Electrochemical detector based on sol-gel-derived carbon composite material for capillary electrophoresis microchips.

An on-chip disk electrode based on sol-gel-derived carbon composite material could be easily and reproducibly fabricated. Unlike other carbon-based electrodes reported previously, this detector is rigid, convenient to fabricate, and amenable to chemical modifications. Based on the stable and reproducible characters of this detector, a copper particle-modified detector was developed for the detection of carbohydrates which extends the application of the carbon-based electrode. In our experiments, the performance of the new integrated detector for rapid on-chip measurement of epinephrine and glucose was illustrated. Experimental procedures including the fabrication of this detector, the configuration of separation channel outlet and electrode verge, and the performance characteristics of this new electrochemical detector were investigated.

Carbon↗

Direct electrochemical detection of glucose in human plasma on capillary electrophoresis microchips.

We developed an electrochemical detector on a hybrid chip for the determination of glucose in human plasma. The microchip system described in this paper consists of a poly(dimethylsiloxane) (PDMS) layer containing separation and injection channels and an electrode plate. The copper microelectrode is fabricated by selective electroless deposition. The fabrication of the decoupler is performed by platinum electrochemical deposition on the metal film formed by electroless deposition. Factors influencing the performance, including detection potential, separation field strength, and buffer concentration, were studied. The electrodes exhibited good stability and durability in the analytical procedures. Under optimized detection conditions, glucose responded linearly from 10 microM to 1 mM. Finally, glucose in human plasma from three healthy individuals and two diabetics was successfully determined, giving a good prospect for a new clinical diagnostic instrument.

Blood Glucose↗

Fabrication of integrated microelectrodes for electrochemical detection on electrophoresis microchip by electroless deposition and micromolding in capillary technique.

A new method for the fabrication of an integrated microelectrode for electrochemical detection (ECD) on an electrophoresis microchip is described. The pattern of the microelectrode was directly made on the surface of a microscope slide through an electroless deposition procedure. The surface of the slide was first selectively coated with a thin layer of sodium silicate through a micromolding in capillary technique provided by a poly(dimethylsiloxane) (PDMS) microchannel; this left a rough patterned area for the anchoring of catalytic particles. A metal layer was deposited on the pattern guided by these catalytic particles and was used as the working electrode. Factors influencing the fabrication procedure were discussed. The whole chip was built by reversibly sealing the slide to another PDMS layer with electrophoresis microchannels at room temperature. This approach eliminates the need of clean room facilities and expensive apparatus such as for vacuum deposition or sputtering and makes it possible to produce patterned electrodes suitable for ECD on microchip under ordinary chemistry laboratory conditions. Also once the micropattern is ready, it allows the researchers to rebuild the electrode in a short period of time when an electrode failure occurs. Copper and gold microelectrodes were fabricated by this technique. Glucose, dopamine, and catechol as model analytes were tested.

Journal Article↗

Microchip capillary electrophoresis with an integrated indium tin oxide electrode-based electrochemiluminescence detector.

This paper describes an indium tin oxide (ITO) electrode-based Ru(bpy)3(2+) electrochemiluminecence (ECL) detector for a microchip capillary electrophoresis (CE). The microchip CE-ECL system described in this article consists of a poly(dimethylsiloxane) (PDMS) layer containing separation and injection channels and an electrode plate with an ITO electrode fabricated by a photolithographic method. The PDMS layer was reversibly bound to the ITO electrode plate, which greatly simplified the alignment of the separation channel with the working electrode and enhanced the photon-capturing efficiency. In our study, the high separation electric field had no significant influence on the ECL detector, and decouplers for isolating the separation electric field were not needed in the microchip CE-ECL system. The ITO electrodes employed in the experiments displayed good durability and stability in the analytical procedures. Proline was selected to perform the microchip device with a limit of detection of 1.2 microM (S/N = 3) and a linear range from 5 to 600 microM.

Journal Article↗

Miniaturized tris(2,2'-bipyridyl)ruthenium(II) electrochemiluminescence detection cell for capillary electrophoresis and flow injection analysis.

The design and performance of a miniaturized chip-type tris(2,2'-bipyridyl)ruthenium(II) [Ru(bpy)3(2+)] electrochemiluminescence (ECL) detection cell suitable for both capillary electrophoresis (CE) and flow injection (FI) analysis are described. The cell was fabricated from two pieces of glass (20 x 15 x 1.7 mm), and the 0.5-mm-diameter platinum disk was used as working electrode held at +1.15 V (vs silver wire quasi-reference), the stainless steel guide tubing as counter electrode, and the silver wire as quasi-reference electrode. The performance traits of the cell in both CE and FI modes were evaluated using tripropylamine, proline, and oxalate and compared favorably to those reported for CE and FI detection cells. The advantages of versatility, sensitivity, and accuracy make the device attractive for the routine analysis of amine-containing species or oxalate by CE and FI with Ru(bpy)3(2+) ECL detection.

Journal Article↗