PubMed Health⌕ Search

Biomedical subjects

Jim A Reekers

Publications and source records attributed to Jim A Reekers.

At least 19 recordsLinked to original sources

Endovascular management of traumatic ruptures of the thoracic aorta: a retrospective multicenter analysis of 28 cases in The Netherlands.

BACKGROUND: Minimally invasive endovascular treatment of a traumatic rupture of the thoracic aorta is a new strategy in the care of multitrauma patients. We report the experience in The Netherlands with endovascular management of patients with acute traumatic ruptures of the thoracic aorta. METHODS: We reviewed 28 patients with a traumatic thoracic aortic rupture treated with a thoracic aortic endograft between June 2000 and April 2004. All patients underwent treatment at one of the four participating level 1 trauma centers. Data collected included age, sex, injury severity score, type of endovascular graft, endovascular operation time, length of stay, length of stay in the intensive care unit, and mortality. Follow-up data consisted of computed tomographic angiography and plain chest radiographs at regular intervals. RESULTS: All patients (mean age, 40.9 years; SD, 18.5 years) experienced severe traumatic injury, and the mean injury severity score was 37.1 (SD, 7.8). All endovascular procedures were technically successful, and the median operating time for the endovascular procedure was 58 minutes (interquartile range, 47-88 minutes). The overall hospital mortality was 14.3% (n = 4), and all deaths were unrelated to the aortic rupture or stent placement. There was no intervention-related mortality during a median follow-up of 26.5 months (interquartile range, 10-34.6 months). Postoperative data showed no severe endovascular graft- or procedure-related morbidity, except for one patient with an asymptomatic collapse of the endovascular graft during regular follow-up. This was corrected by placing a second graft. CONCLUSIONS: This study shows that the results of immediate endovascular repair of a traumatic aortic rupture are at least equal to those of conventional open surgical repair. Especially in these multitrauma patients with traumatic ruptures of the thoracic aorta, endovascular therapy seems to be preferable to conventional open surgical repair.

Aorta, Thoracic↗

Uterine artery embolization in the treatment of symptomatic uterine fibroid tumors (EMMY trial): periprocedural results and complications.

PURPOSE: Uterine artery embolization (UAE) is an emerging treatment for symptomatic uterine fibroid tumors. This study was performed to evaluate the periprocedural results of the UAE procedure and identify risk factors for technical failure, fever after UAE, pain, and other complications. MATERIALS AND METHODS: As part of a multicenter, randomized trial to compare UAE versus hysterectomy in patients with symptomatic uterine fibroid tumors, 81 patients underwent UAE. Univariate and multivariate analyses were used to identify predictors for technical failure, postprocedural fever, complications as defined by the Society of Interventional Radiology (SIR), and pain scores. RESULTS: The technical failure rate according to SIR guidelines was 5.3% (95% CI, 2.3%-10.1%). The procedural failure rate was 17.3% (95% CI, 9.8%-27.3%). Bilateral failure occurred in four of 81 patients and unilateral failure occurred in 10 of 81 patients. Technical failure occurred mainly as a result of difficult anatomy (3.7%) or absence of the uterine artery (3.1%). The overall complication rates were 28.4% during the patients' hospital stay and 60.5% for the 6 weeks after discharge. The risk of technical failure was found to increase in the presence of a single fibroid tumor (odds ratio [OR], 6.21; 95% CI, 1.65-23.41; P = .007) and/or a small uterine volume (<500 cm(3); OR, 10.8; 95% CI, 1.25-93.36; P = .03). The amount of embolization material was associated with the onset of fever after UAE (OR, 2.05; 95% CI, 1.09-3.87; P = .027), major complications (OR, 5.68; 95% CI, 2.05-15.75; P = .001), and high pain scores (OR, 1.97; 95% CI, 1.08-3.58; P = .027). CONCLUSIONS: The procedural failure rate for UAE was higher than those reported by others, mainly as a result of difficult anatomy and absence of a uterine artery in some cases. The risk of procedural failure was increased for patients with single fibroid tumors and/or small uterine volumes. A clear dose-effect response was revealed between the amount of embolization material used and the risk for postprocedural fever, major complications, and severe pain.

Adult↗

Uterine artery embolization versus hysterectomy in the treatment of symptomatic uterine fibroids (EMMY trial): peri- and postprocedural results from a randomized controlled trial.

OBJECTIVE: This was a randomized controlled trial to evaluate the safety of uterine artery embolization (UAE) compared with hysterectomy. STUDY DESIGN: Twenty-eight Dutch hospitals recruited 177 patients with symptomatic uterine fibroids and menorrhagia who were eligible for hysterectomy. Patients were randomized to UAE (n = 88) or hysterectomy (n = 89). In this paper we evaluate the peri- and postprocedural complications, length of hospital stay, unscheduled visits, and readmission rates up to 6 weeks' post-intervention. Analysis was by intention to treat. RESULTS: Bilateral UAE failure occurred in 4 patients (4.9%). Major complications occurred in 4.9% (UAE) and 2.7% (hysterectomy) of cases (P = .68). The minor complication rate from discharge until 6 weeks after was significantly higher in the UAE group than in the hysterectomy group (58.0% vs 40.0%; RR 1.45 [1.04-2.02]; P = .024). UAE patients were more often readmitted (11.1% vs 0%; P = .003). Total length of hospital stay was significantly shorter in UAE patients (mean [SD]: 2.5 [2.7] vs 5.1 [1.3], P < .001). CONCLUSION: UAE is a procedure similar to hysterectomy with a low major complication rate and with a reduced length of hospital stay. Higher readmission rates after UAE stress the need for careful postprocedural follow-up.

Adult↗

Thrombolytic therapy for acute superior mesenteric artery occlusion.

The aim of this review is to evaluate thrombolytic therapy for acute superior mesenteric artery occlusion as an alternative or adjunctive treatment modality to surgical therapy and to provide current knowledge for timely and informed decisions regarding treatment of acute mesenteric ischemia. A systematic analysis of the available literature from 1966 to 2003 regarding thrombolytic therapy for superior mesenteric artery thromboembolism was performed. A total of 20 case reports and seven small series covered 48 patients with acute superior mesenteric artery thromboembolism. In the herein reviewed series, thrombolytic therapy of acute superior mesenteric artery thromboembolism resulted in angiographic resolution of the thromboembolism in 43 patients, in clinical success without requiring additional surgical intervention in 30 patients, and in survival in 43 patients, with similar complication rates as in thrombolytic treatment of peripheral vascular occlusions. Remission of abdominal pain during the first few hours of treatment formed the most important indicator of therapeutic success. Insufficient evidence from reviewed literature is available to determine the relative effectiveness and safety of thrombolytic treatment for acute superior mesenteric artery thromboembolism; however, initial results appear to be promising. Thrombolytic therapy can be effective relatively quickly, may obviate surgery, and has the potential to resolve the clot completely. In some cases it can be used as an alternative or neo-adjunctive treatment modality to surgery. A treatment guideline for thrombolysis of acute superior mesenteric artery thromboembolism should be developed.

Algorithms↗

Collapse of a stent-graft following treatment of a traumatic thoracic aortic rupture.

PURPOSE: To report a collapsed stent-graft used to treat a traumatic aortic rupture. CASE REPORT: A Gore TAG stent-graft was placed in a 20-year-old man with multiple injuries. Postimplantation computed tomographic angiography (CTA) demonstrated no contrast extravasation and total exclusion of the traumatic rupture. Routine CTA 3 months after implantation revealed a collapsed stent-graft located in the outer curve of the distal aortic arch. A Talent stent-graft was placed successfully within the collapsed prosthesis. Postimplantation CTA demonstrated no contrast extravasation and good apposition of the endograft to the aortic wall. At 6 months, the repair remains secure; there is no sign of graft collapse or endoleak. CONCLUSIONS: Collapse of stent-grafts can occur after treatment for traumatic aortic ruptures; endovascular methods can be used to restore a satisfactory luminal contour.

Accidents, Traffic↗

Diagnosis and management of deep vein thrombosis of the upper extremity: a review.

Deep vein thrombosis of the upper extremity is an increasing clinical problem due to the use of long-term indwelling catheters for chemotherapy or long-term feeding. The clinical diagnosis is difficult to make, and various imaging modalities have been used for this purpose. The use of (interventional) radiological procedures has been advancing in recent years. This review describes the clinical background, the imaging modalities that may be employed, treatment options and outcome of patients with upper extremity thrombosis.

Anticoagulants↗

Myoma expulsion after uterine artery embolization: complication or cure?

A 54-year-old woman had an expulsed myoma 10 weeks after uterine artery embolization. After treatment with antibiotics and a small surgical intervention, she recovered completely without any sign of myomatous disease afterwards. Patients should be informed about the possibility of expulsion. Expulsion of myomas after uterine artery embolization occurs relatively frequently and may be just one of the ways to attain cure.

Arteries↗

Long-term follow-up of patients with suspected deep vein thrombosis of the upper extremity: survival, risk factors and post-thrombotic syndrome.

BACKGROUND: The outcome of upper extremity thrombosis in terms of morbidity, mortality and arm functionality is virtually unknown. We investigated mortality, risk factors, recurrent thrombosis and post-thrombotic syndrome (PTS) in patients with suspected upper extremity thrombosis. METHODS: Consecutive patients suspected of having deep vein thrombosis (DVT) of the upper extremity were followed for up to 53 months (mean 21 months). Venography and/or ultrasonography was used for diagnosis. Risk factors were identified from history and thrombophilia laboratory screening. PTS was assessed using a scoring system. Death, recurrent thrombosis and PTS were primary outcome measures. RESULTS: DVT of the upper extremity was diagnosed in 50 of 116 consecutive patients (43%). Malignancy and/or central venous lines were present in 37 of 50 (74%) patients with thrombosis. Inherited thrombophilia was diagnosed in 6 of 30 (20%) and 4 of 33 (12%) of the investigated patients with and without thrombosis, respectively (not significant). Twenty-five patients (50%) with thrombosis died during the follow-up period; this was associated with cancer in 84% of the deaths. Recurrent thrombosis was observed in four patients (8%) during follow-up. Symptoms of PTS were present in 4 of 22 patients (18%) with thrombosis and in 14 of 36 patients (39%) in whom thrombosis was excluded. CONCLUSIONS: Malignancy and central venous lines are major risk factors of upper extremity thrombosis. Thrombophilia seems to be unrelated to the presence or absence of upper extremity thrombosis. Thrombosis in combination with malignancy predicts poor survival. A scoring system can be used to assess the severity of PTS, but it does not discriminate PTS from other causes of arm complaints.

Journal Article↗

Evaluation of the retrievability of the OptEase IVC filter in an animal model.

PURPOSE: A new inferior vena cava filter was evaluated in vivo to determine the percutaneous retrievability after an implantation period of up to 18 days. MATERIALS AND METHODS: The inferior venae cavae of six goats were percutaneously implanted with three filters, and one animal received two filters. To assess filter stability, a plain radiograph was obtained after 7-9 days and on the day of retrieval. After cavography, filter retrieval with an endovascular snare and retrieval catheter was performed in three animals after 12 days and in three others after 14 days. In one animal, retrieval of one filter was performed after 18 days, and one filter was intended to be permanent. Twenty-eight days after filter retrieval, cavography was performed before inferior vena cava removal for gross and histologic examination. RESULTS: All filters (N = 20) were implanted without complications. There was no migration during the implantation period. Preretrieval cavography demonstrated all filters to be patent and centered. Filters intended for retrieval (n = 19) were all successfully extracted at 12 (nine filters), 14 (nine filters), and 18 days (one filter). For the animal with the filter extracted at 18 days, one filter remained in situ intentionally. Postretrieval cavography showed no visible signs of vessel wall anomalies. There were no complications during the 28 days of follow-up after retrieval. Presacrifice cavography showed no evidence of caval wall abnormalities. In all animals, gross examination of the inner wall of the explanted vena cava showed only minimal macroscopic changes. The struts of the filter in situ for 46 days (18 days with 28 days of follow-up) were overgrown with neointima. Histological study of the 19 filter retrieval sites revealed no to moderate intima proliferation, minimal residual signs of hemorrhages, and no or only occasional slight inflammatory reaction. CONCLUSIONS: In this animal model, the new vena cava filter demonstrated event-free retrieval, without postretrieval complications, up to 18 days postimplantation. After implantation of 46 days, the filter showed neointima overgrowth of the struts.

Animals↗

Removal of arterial wall calcifications in CT angiography by local subtraction.

CT Angiography (CTA) is an established technique for the minimally invasive imaging of arteries. The technique of maximum intensity projection (MIP) is often used to get a comprehensive overview of the vascular anatomy. On a MIP, however, arterial wall calcifications may hinder the visualization of the arterial lumen. These calcifications are in direct contact with the contrast-enhanced blood, which makes removal difficult. We present a local subtraction method for the automatic removal of these calcifications. In our approach a second CT scan has to be made, prior to contrast injection. The calcifications in both scans are registered prior to subtraction to compensate for displacements in between the two scans. Local subtraction results are compared with results obtained by thresholding. The method was tested in a phantom and with data from four patients. The phantom represented an artery with different types of stenosis. Data were used from patients for which CTA of the renal arteries was performed. For two patients the electrocardiogram (ECG) was recorded during the CTA examination, making retrospective cardiac gated reconstructions possible. Both the phantom and the patient study showed that the local subtraction method is capable of removing calcifications and visualizing the residual lumen. In the patient study it appeared that some artifacts remained for higher pitch values. We conclude that the local subtraction method is less subjective and more accurate than thresholding. Best results are obtained by use of a small pitch, at the expense of the volume covered during a single breath hold.

Algorithms↗

Prospective study of color duplex ultrasonography compared with contrast venography in patients suspected of having deep venous thrombosis of the upper extremities.

BACKGROUND: The optimal strategy for diagnosis of deep venous thrombosis (DVT) is less well established for the upper extremities than for the lower extremities. Duplex color ultrasonography can be difficult to perform in the upper extremities because of their anatomy, and contrast venography is often indicated. Moreover, limited data exist on the use of duplex color ultrasonography in this setting. OBJECTIVE: To determine the accuracy of duplex ultrasonography for diagnosis of DVT of the upper extremities. DESIGN: Prospective study of duplex ultrasonography compared with venography. SETTING: A teaching hospital in Amsterdam, the Netherlands. PATIENTS: 126 consecutive inpatients and outpatients with suspected DVT of the upper extremities. MEASUREMENTS: Contrast venography was obtained after duplex ultrasonography and was judged independently. A three-step protocol, involving compression ultrasonography, color ultrasonography, and color Doppler ultrasonography, was used. Sensitivity, specificity, and likelihood ratios for ultrasonography as a whole were calculated. The independent value of each step was assessed. RESULTS: Venography and ultrasonography were not feasible in 23 of 126 patients (18%) and 1 of 126 patients (0.8%), respectively. Results of ultrasonography were inconclusive in 3 patients. Venography demonstrated thrombosis in 44 of 99 patients (44%); in 36 patients (36%), thrombosis was related to intravenous catheters or malignant disease. Sensitivity and specificity of duplex ultrasonography were 82% (95% CI, 70% to 93%) and 82% (CI, 72% to 92%), respectively. Venous incompressibility correlated well with thrombosis, whereas only 50% of isolated flow abnormalities proved to be thrombosis-related. CONCLUSIONS: Duplex ultrasonography may be the method of choice for initial diagnosis of patients with suspected thrombosis of the upper extremities. However, in patients with isolated flow abnormalities, contrast venography should be performed.

Adolescent↗

Deep vein thrombosis of the upper extremity: intra- and interobserver study of digital subtraction venography.

Our objective was to assess the inter-observer and intra-observer agreement in the interpretation of digital subtraction venography (DSV) in patients with suspected deep vein thrombosis of the upper extremity (DVTUE). Prospectively, 62 consecutive DSV studies in 54 patients with clinically suspected DVTUE were included. Hard copies were presented without demographic data or original report. All venograms were read twice, at 3-month intervals, by an interventional vascular radiologist (observer 1) and an experienced general radiologist (observer 2). Consensus reading took place in the presence of a third experienced interventional radiologist. Inter-observer and intra-observer agreement were assessed using kappa statistics. Initial reading in 62 venograms showed an inter-observer agreement of 71% (kappa 0.48). The inter-observer agreement of the second reading was 83% (kappa 0.71). The agreement with the consensus report ranged from 76 to 94%. The intra-observer agreement for the first and second observer was 94% (kappa 0.89) and 76% (kappa 0.56), respectively ( p<0.01). Digital subtraction venography has moderate to excellent intra- and inter-observer agreement, suggesting that digital subtraction venography is reliable for the diagnosis of DVTUE.

Adolescent↗

Evaluation of vascular and interventional procedures with time-action analysis: a pilot study.

PURPOSE: To provide an objective method to measure the efficiency of vascular and interventional procedures. MATERIALS AND METHODS: The time-action analysis method is defined for peripheral vascular and interventional procedures. A taxonomy of actions is defined, geared specifically toward these procedures. The actions are: start-up/wrap-up, exchange, navigate, image, diagnose, treat, handle material, wait, compress puncture site, and unclassified. The recording method and analysis techniques are described. To show the type of data that can be obtained, the time-action analysis of 30 procedures is presented. RESULTS: The results provide a detailed picture of the time spent on various actions. Of all actions, the most time is spent on compressing the puncture site (18.5%), whereas the highest frequency of actions are for exchange of catheters, guide wires, and sheaths (20.4 times per procedure). Radiation exposure can be analyzed in detail, which can yield directions for possible reduction. For instance, 5.2%-8.3% of the total radiation exposure occurs during preparation of imaging to adjust the position of the patient table and set the image intensifier diaphragm. CONCLUSION: Time-action analysis provides an objective measurement method to monitor and evaluate vascular and interventional procedures. Potential applications and limitations of the technique are discussed.

Equipment Design↗

Emergency endovascular treatment of thoracic aortic rupture in three accident victims with multiple injuries.

PURPOSE: To report an experience with emergency endovascular treatment of traumatic thoracic aortic ruptures in multi-injured patients. CASE REPORTS: Three victims of motor vehicle accidents with multiple head, chest, and abdominal injuries in addition to fractures were treated urgently for thoracic aortic lacerations with transluminal placement of an endovascular graft during the initial emergent laparotomy. In all cases, ruptured visceral organs were treated first and the abdomen closed. Femoral artery access was gained through a cutdown, and the endografts were delivered with no systemic heparinization. The endovascular component of the surgical session took approximately 50 minutes. All patients survived to discharge. Two patients are alive at 5 and 12 months with sustained endovascular exclusion of the pseudoaneurysm, but one patient with severe brain damage died 9 months after treatment from respiratory insufficiency. CONCLUSIONS: Acute endovascular treatment of thoracic aortic ruptures is feasible and has the advantage of avoiding thoracotomy in otherwise severely injured patients.

Accidents, Traffic↗