PubMed Health⌕ Search

Biomedical subjects

Jingfu Liu

Publications and source records attributed to Jingfu Liu.

11 recordsLinked to original sources

Determination of 3-chloropropane-1,2-diol in liquid hydrolyzed vegetable proteins and soy sauce by solid-phase microextraction and gas chromatography/mass spectrometry.

Headspace solid-phase microextraction (HS-SPME) coupled with gas chromatography/mass spectrometry (GC/MS) method was developed to determine 3-chloropropane-1,2-diol (3-MCPD) in hydrolyzed vegetable protein and Chinese soy sauce. The 3-MCPD was firstly derivativized with phenylboronic acid in aqueous solution at 90 degrees C for 10 min, then extracted by HS-SPME and finally detected with GC/MS, parameters related to both the derivative reaction and the HS-SPME process were optimized. The proposed method has a linear range of 0.0194-394 microg g(-1), a detection limit of 3.87 ng g(-1) (S/N = 3), and a precision of RSD = 7.5% (n = 5). Seventeen real samples, including four HVPs and thirteen soy sauce samples, were analyzed to examine the feasibility of the proposed procedure; with a concentration of 3-MCPD and acceptable recoveries at 0.71 microg g(-1) spiked levels were obtained. Being simpler, faster and more environmentally benign than the existing methods, this method is accurate and suitable for routine analysis.

Boronic Acids↗

Sensitivity enhancement of chlorinated phenols by continuous flow liquid membrane extraction followed by capillary electrophoresis.

This paper describes a new analytical system, based on the combination of continuous flow liquid membrane extraction (CFLME) enrichment and capillary electrophoresis (CE) separation, for analysis of chlorinated phenols in water samples. Five chlorinated phenols including 3-chlorophenol (3CP), 4-chlorophenol (4CP) 2,4-dichlorophenol (DCP), 2,4,6-trichlorophenol (TCP), and pentachlorophenol (PCP) were separated by CE with Tris/sodium dihydrogen phosphate solution containing methanol 1% (v/v) as the run buffer. CFLME related parameters were investigated and optimal enrichment was obtained by using 0.3 mol L(-1) Tris as acceptor and with a sample pH 5.0, a sample flow rate of 4.0 mL min(-1), and an enrichment sample volume of 150 mL. The detection limit (S/N= 3) was 6.9, 1.0, and 1.7 ng mL(-1) for DCP, PCP, and TCP, respectively. The reproducibility (RSD%, n = 6) was 5.7 for DCP, 2.5 for PCP, and 2.8% for TCP (n = 6). The proposed method was applied to the determination of chlorinated phenols in spiked water samples with relatively satisfactory recoveries.

Calibration↗

Determination of 4-tert-octylphenol, 4-nonylphenol and bisphenol A in surface waters from the Haihe River in Tianjin by gas chromatography-mass spectrometry with selected ion monitoring.

The estrogenic pollutants 4-tert-octylphenol (OP), 4-nonylphenol (NP) and bisphenol A (BPA) were determined in surface water samples from the Haihe River, Tianjin, China. The analytes were extracted and concentrated from 300 ml acidified water samples by liquid-liquid extractions using dichloromethane, derivatized with trifluoroacetic anhydride, and quantified by gas chromatography-mass spectrometry (GC-MS) with selected ion monitoring (SIM). Among the samples collected from 14 sampling sites, only one sample was found to have a relatively high concentration of BPA (8.30 microgl(-1)) and NP (0.55 microgl(-1)). The concentrations of OP, NP and BPA in the other samples were in the range of 18.0-20.2, 106-296 and 19.1-106 ngl(-1), respectively. Recoveries for OP, NP and BPA in the spiked water samples were all over 80%.

Benzhydryl Compounds↗

A rapid two-step chromatographic method for the quantitative determination of vitellogenin in fish plasma.

By combining anion-exchange membrane purification with high-performance size-exclusion chromatography (HPSEC) analysis, a two-step chromatographic method was developed for the determination of vitellogenin (Vtg) in fish plasma. Most plasma protein interferences can be removed during anion-exchange membrane purification process. Vtg is eluted from the size-exclusion chromatography column with a retention time of about 9 min and is characterized based on the native molecular weight, with a limit of quantification of 20 microg Vtg mL(-1)plasma. The spiked recovery and interassay variability were better than 80% and 4.8%. This method was successfully applied to analyze the plasma Vtg levels of loach (Misgurnus angaillicaudatus) and sea catfish (Enchelyopus elongatus). In addition to all the female fish, Vtg is detected in 75% of male loaches and 100% of male sea catfish. The result indicates that some chemicals or unknown factors with estrogenic activity have induced male fish to produce Vtg.

Animals↗

Multiwalled carbon nanotubes as a solid-phase extraction adsorbent for the determination of bisphenol A, 4-n-nonylphenol, and 4-tert-octylphenol.

The adsorptive potential of multiwalled carbon nanotubes (MWNTs) for solid-phase extraction of bisphenol A, 4-n-nonylphenol, and 4-tert-octylphenol was investigated for the first time. The three analytes are quantitatively adsorbed on a MWNTs-packed cartridge, then the analytes retained on the cartridge are quantitatively desorbed with suitable amounts of methanol. Finally, the analytes in the methanol eluate are determined by high performance liquid chromatography-fluorometric detection. Parameters influencing the extraction efficiency, such as volume of the sample solutions, pH of the sample, and the eluent volume, were examined. Comparative studies showed that MWNTs were superior to C18 for the extraction of the more polar analyte bisphenol A and at least as effective as C18 for the extraction of 4-n-nonylphenol and 4-tert-octylphenol. Compared to XAD-2 copolymer, MWNTs exhibited a better property for the extraction of all three analytes. The developed method has been applied to determine bisphenol A, 4-n-nonylphenol, and 4-tert-octylphenol in several environmental water samples. The accuracy of the proposed method was tested by recovery measurements on spiked samples, and good recovery results (89.8-104.2%) were obtained. Detection limits of 0.083, 0.024, and 0.018 ng mL(-1) for bisphenol A, 4-n-nonylphenol, and 4-tert-octylphenol, respectively, were achieved under the optimized conditions.

Adsorption↗

Membrane chromatographic method for the rapid purification of vitellogenin from fish plasma.

A membrane chromatographic method was developed for the rapid purification of vitellogenin (Vtg) from the plasma of 17beta-estradiol induced loach (Misgurnus angaillicaud atus) and carp (Cyprinus carpio). The time required for the proposed procedure is less then 10 min at a flow-rate of 5 ml/min of the mobile phase, and 0.5 ml of fish plasma could be separated in one cycle. Multistep gradient elution was more suitable for the separation than linear gradient elution. Under optimized conditions, a single Vtg peak can be obtained and its identity was confirmed by SDS-PAGE and gel-permeation chromatography assessment. This method is rapid and easy to operate compared to conventional HPLC and FPLC columns for Vtg separation.

Animals↗

Separation and determination of methyl tert-butyl ether and its degradation products by a laboratory-constructed micro-cryogenic chromatographic oven.

A laboratory-made micro-cryogenic chromatographic oven was mainly improved in size, which was controlled at 6 x 6 x 2.5 cm. A thermoelectric system was used to cool the capillary column instead of the traditional liquid cryogen. A cold block connected to the cryogenic module was directly solidified at room temperature with thermally conductive adhesive so that the uniformity of transferring heat was greatly improved, and the size of the system was reduced. Moreover, this system was inexpensive and convenient for both operation and control. The newly developed device coupled with headspace solid-phase microextraction (SPME) was successfully applied to the determination of methyl tert-butyl ether (MTBE) and its degradation products. During the analysis procedure, a 65 microm polydimethylsiloxane/divinylbenzene (PDMS/DVB) fiber was used to extract MTBE and its degradation products. The extraction was controlled at 50 degrees C for 30 min and the NaCl content in the sample was maintained at 35%. The limits of detection (LODs) ranged from 0.006 microg mL(-1) (for MTBE) to 0.206 microg mL(-1) (for methyl acetate) and the relative standard deviations (RSD%) were below 4%. The spiked recoveries for the developed method were evaluated using various water samples as a matrix.

Chromatography↗

Solid-phase extraction of several phthalate esters from environmental water samples on a column packed with polytetrafluoroethylene turnings.

A method for the determination of several phthalate esters in water samples using solid-phase extraction coupled to high-performance liquid chromatography was developed. A polytetrafluoroethylene turnings packed column was used as a SPE adsorbent material. The analytes were sorbed on polytetrafluoroethylene turnings, from which they were eluted by a small amount of acetonitrile, followed by a RP-HPLC-UV analysis. Detection limits (3sigma) of 4.7, 3.1, 3.6, 4.3, and 5.8 ng mL(-1) for di-n-butyl-phthalate, di-cyclohexyl-phthalate, di-n-octyl-phthalate, di-n-nonyl-phthalate and di-iso-decyl-phthalate, respectively, were achieved. Acceptable recovery results (92.1-127.5%) were obtained on five phthalate esters spiked samples.

Journal Article↗

Determination of volatile residual solvents in traditional Chinese medicines by headspace solid-phase microextraction and cryogenic gas chromatography with flame ionization detection.

A method based on headspace solid-phase microextraction and cryogenic gas chromatography with flame ionization detection was developed for the determination of volatile residual solvents in traditional Chinese medicines. A laboratory-made cryogenic chromatographic system was used for the separation of 15 kinds of residual solvents. During the analysis, a 65 microm PDMS/DVB fiber was used to extract the residual solvents, the extraction time was controlled at 0 degrees C for 15 min, and the NaCl content of the sample was maintained at 30%. The limits of detection ranged from 0.08 (for octane) to 5000 microg/L (for ethanol), and the relative standard deviations were < 8%. The recoveries from spiked samples ranged from 88 to 112%. Trace levels of residual solvents in several traditional Chinese medicines were effectively identified and quantified.

Calibration↗