PubMed Health⌕ Search

Biomedical subjects

Jinlan Huang

Publications and source records attributed to Jinlan Huang.

2 recordsLinked to original sources

Producing diffuse ultrasound reflections from medical instruments using a quadratic residue diffuser.

Simultaneous visualization of tissue and surgical instruments is necessary during ultrasound-guided medical procedures. Standard minimally invasive instruments are typically metallic and act as strong specular scatterers. As a result, such instruments saturate the image or disappear according to the angle of incidence, obscuring nearby tissue and making it difficult to determine the instrument's precise location. The objective of this study was to produce diffusive reflections from the surface of surgical instruments for improved visualization in ultrasound. A surface profile based on a 2D quadratic residue diffuser (QRD) was employed, which has been demonstrated to reduce specular reflection in other acoustic applications. The backscattered echo amplitude from the diffusive surface at various angles of insonation was measured and compared to that from unmodified metal surfaces and heart tissue surfaces. The QRD resulted in an 8 dB reduction of the specular signal. Furthermore, the dynamic range for angles up to 75 degrees was less than 20 dB for the QRD and more than 65 dB for a flat surface. The QRD surface produces two beneficial results for the simultaneous imaging of instruments and tissue. First, the conspicuity of diffusive surfaces in ultrasound images is markedly improved in comparison with unmodified metal surfaces. Secondly, the echo amplitude of diffusive metal surfaces differs in mean and standard deviation from that of tissue facilitating image enhancement and segmentation.

Acoustics↗

Experimental validation of a tractable numerical model for focused ultrasound heating in flow-through tissue phantoms.

Heating from high intensity focused ultrasound (HIFU) can be used to control bleeding, both from individual blood vessels as well as from gross damage to the capillary bed. The presence of vascularity can limit one's ability to elevate the temperature owing to convective heat transport. In an effort to better understand the heating process in tissues with vascular structure we have developed a numerical simulation that couples models for ultrasound propagation, acoustic streaming, ultrasound heating and blood cooling in a Newtonian viscous medium. The 3-D simulation allows for the study of complicated biological structures and insonation geometries. We have also undertaken a series of in vitro experiments employing non-uniform flow-through tissue phantoms and designed to provide verification of the model predictions. We show that blood flow of 2 cm/s (6.4 ml/min through a 2.6 mm 'vessel') can reduce peak temperature in a vessel wall by 25%. We also show that HIFU intensities of 6.5 x 10(5) W/m2 can induce acoustic streaming with peak velocities up to 5 cm/s and this can reduce heating near a vessel wall by more than 10%. These results demonstrate that convective cooling is important in HIFU and can be accounted for within simulation models.

Algorithms↗