PubMed Health⌕ Search

Biomedical subjects

Jiucang Hao

Publications and source records attributed to Jiucang Hao.

4 recordsLinked to original sources

Relevance vector machine and support vector machine classifier analysis of scanning laser polarimetry retinal nerve fiber layer measurements.

PURPOSE: To classify healthy and glaucomatous eyes using relevance vector machine (RVM) and support vector machine (SVM) learning classifiers trained on retinal nerve fiber layer (RNFL) thickness measurements obtained by scanning laser polarimetry (SLP). METHODS: Seventy-two eyes of 72 healthy control subjects (average age = 64.3 +/- 8.8 years, visual field mean deviation = -0.71 +/- 1.2 dB) and 92 eyes of 92 patients with glaucoma (average age = 66.9 +/- 8.9 years, visual field mean deviation = -5.32 +/- 4.0 dB) were imaged with SLP with variable corneal compensation (GDx VCC; Laser Diagnostic Technologies, San Diego, CA). RVM and SVM learning classifiers were trained and tested on SLP-determined RNFL thickness measurements from 14 standard parameters and 64 sectors (approximately 5.6 degrees each) obtained in the circumpapillary area under the instrument-defined measurement ellipse (total 78 parameters). Ten-fold cross-validation was used to train and test RVM and SVM classifiers on unique subsets of the full 164-eye data set and areas under the receiver operating characteristic (AUROC) curve for the classification of eyes in the test set were generated. AUROC curve results from RVM and SVM were compared to those for 14 SLP software-generated global and regional RNFL thickness parameters. Also reported was the AUROC curve for the GDx VCC software-generated nerve fiber indicator (NFI). RESULTS: The AUROC curves for RVM and SVM were 0.90 and 0.91, respectively, and increased to 0.93 and 0.94 when the training sets were optimized with sequential forward and backward selection (resulting in reduced dimensional data sets). AUROC curves for optimized RVM and SVM were significantly larger than those for all individual SLP parameters. The AUROC curve for the NFI was 0.87. CONCLUSIONS: Results from RVM and SVM trained on SLP RNFL thickness measurements are similar and provide accurate classification of glaucomatous and healthy eyes. RVM may be preferable to SVM, because it provides a Bayesian-derived probability of glaucoma as an output. These results suggest that these machine learning classifiers show good potential for glaucoma diagnosis.

Aged↗

Using unsupervised learning with independent component analysis to identify patterns of glaucomatous visual field defects.

PURPOSE: Clustering by unsupervised learning with machine learning classifiers was shown to segment clusters of patterns in standard automated perimetry (SAP) for glaucoma in previous publications. In this study, unsupervised learning by independent component analysis decomposed SAP field patterns into axes, and the information represented by these axes was evaluated. METHODS: SAP fields were used that were obtained with the Humphrey Visual Field Analyzer (Carl Zeiss Meditec, Dublin, CA) from 189 normal eyes and 156 eyes with glaucomatous optic neuropathy (GON) determined by masked review with stereoscopic optic disc photographs. The variational Bayesian independent component analysis mixture model (vB-ICA-mm) partitioned the SAP fields into the most informative number of clusters. Simultaneously, the model learned an optimal number of maximally independent axes for each cluster. RESULTS: The most informative number of clusters in the SAP set was two. vB-ICA-mm placed 68.6% of the eyes with GON in a cluster labeled G and 98.4% of the eyes with normal optic discs in a cluster labeled N. Cluster G optimally contained six axes. Post hoc analysis of patterns generated at -1 SD and +2 SD from the cluster G mean on the six axes revealed defects similar to those identified by experts as indicative of glaucoma. SAP fields associated with an axis showed increasing severity, as they were located farther in the positive direction from the cluster G mean. CONCLUSIONS: vB-ICA-mm represented the SAP fields with patterns that were meaningful for glaucoma experts. This process also captured severity in the patterns uncovered. These findings should validate vB-ICA-mm as a data-mining technique for new and unfamiliar complex tests.

Artificial Intelligence↗

Using unsupervised learning with variational bayesian mixture of factor analysis to identify patterns of glaucomatous visual field defects.

PURPOSE: To determine whether an unsupervised machine learning classifier can identify patterns of visual field loss in standard visual fields consistent with typical patterns learned by decades of human experience. METHODS: Standard perimetry thresholds for 52 locations plus age from one eye of each of 156 patients with glaucomatous optic neuropathy (GON) and 189 eyes of healthy subjects were clustered with an unsupervised machine classifier, variational Bayesian mixture of factor analysis (vbMFA). RESULTS: The vbMFA formed five distinct clusters. Cluster 5 held 186 of 189 fields from normal eyes plus 46 from eyes with GON. These fields were then judged within normal limits by several traditional methods. Each of the other four clusters could be described by the pattern of loss found within it. Cluster 1 (71 GON + 3 normal optic discs) included early, localized defects. A purely diffuse component was rare. Cluster 2 (26 GON) exhibited primarily deep superior hemifield defects, and cluster 3 (10 GON) held deep inferior hemifield defects only or in combination with lesser superior field defects. Cluster 4 (6 GON) showed deep defects in both hemifields. In other words, visual fields within a given cluster had similar patterns of loss that differed from the predominant pattern found in other clusters. The classifier separated the data based solely on the patterns of loss within the fields, without being guided by the diagnosis, placing 98.4% of the healthy eyes within the same cluster and spreading 70.5% of the eyes with GON across the other four clusters, in good agreement with a glaucoma expert and pattern standard deviation. CONCLUSIONS: Without training-based diagnosis (unsupervised learning), the vbMFA identified four important patterns of field loss in eyes with GON in a manner consistent with years of clinical experience.

Algorithms↗

Confocal scanning laser ophthalmoscopy classifiers and stereophotograph evaluation for prediction of visual field abnormalities in glaucoma-suspect eyes.

PURPOSE: To determine whether Heidelberg Retina Tomograph (HRT; Heidelberg Engineering, Dossenheim, Germany) classification techniques and investigational support vector machine (SVM) analyses can detect optic disc abnormalities in glaucoma-suspect eyes before the development of visual field abnormalities. METHODS: Glaucoma-suspect eyes (n = 226) were classified as converts or nonconverts based on the development of repeatable (either two or three consecutive) standard automated perimetry (SAP)-detected abnormalities over the course of the study (mean follow-up, approximately 4.5 years). Hazard ratios for development of SAP abnormalities were calculated based on baseline classification results, follow-up time, and end point status (convert, nonconvert). Classification techniques applied were HRT classification (HRTC), Moorfields Regression Analysis, forward-selection optimized SVM (SVM fwd) and backward elimination-optimized SVM (SVM back) analysis of HRT data, and stereophotograph assessment. RESULTS: Univariate analyses indicated that all classification techniques were predictors of the development of two repeatable abnormal SAP results, with hazards ratios (95% confidence interval [CI]) ranging from 1.32 (1.00-1.75) for HRTC to 2.0 (1.48-2.76) for stereophotograph assessment (all P < or = 0.05). Only SVM (SVM fwd and SVM back) analysis of HRT data and stereophotograph assessment were univariate predictors of the development of three repeatable abnormal SAP results, with hazard ratios (95% CI) ranging from 1.73 (1.16-2.82) for SVM fwd to 1.82 (1.19-3.12) for SVM back (both P < 0.007). Multivariate analyses including each classification technique individually in a model with age, baseline SAP pattern standard deviation [PSD], and baseline IOP indicated that all classification techniques except HRTC (P = 0.06) were predictors of the development of two repeatable abnormal SAP results with hazards ratios ranging from 1.30 (0.99, 1.73) for HRTC to 1.90 (1.37, 2.69) for stereophotograph assessment. Only SVM (SVM fwd and SVM back) analysis of HRT data and stereophotograph assessment were significant predictors of the development of three repeatable abnormal SAP results in multivariate analyses; hazard ratios of 1.57 (1.03, 2.59) and 1.70 (1.18, 2.51), respectively. SAP PSD was a significant predictor of two repeatable abnormal SAP results in multivariate models with all classification techniques, with hazard ratios ranging from 3.31 (1.39, 7.89) to 4.70 (2.02, 10.93) per 1-dB increase. CONCLUSIONS: HRT classifications techniques and stereophotograph assessment can detect optic disc topography abnormalities in glaucoma-suspect eyes before the development of SAP abnormalities. These data support strongly the importance of optic disc examination for early glaucoma diagnosis.

Adult↗