PubMed Health⌕ Search

Biomedical subjects

Jo Ann Jackson

Publications and source records attributed to Jo Ann Jackson.

3 recordsLinked to original sources

Dynamic monitoring of cytotoxicity on microelectronic sensors.

A real-time cell electronic sensing (RT-CES) system was used for label-free, dynamic measurement of cell responses to cytotoxicants. Cells were grown onto the surfaces of microelectronic sensors, which are comprised of circle-on-line electrode arrays and are integrated into the bottom surfaces of the microtiter plate. Changes in cell status such as cell number, viability, morphology, and adherence were monitored and quantified by detecting sensor electrical impedance. For cell quantification and viability measurement, the data generated on the RT-CES system correlated well with those from the colorimetric (MTT) assay. For cytotoxicity assessment, cells growing on microelectronic sensors were treated with different cytotoxicants, such as arsenic, mercury, and sodium dichromate. The dynamic responses of the cells to the toxicants were continuously monitored by the RT-CES system. On the basis of the IC50 values, the RT-CES system displays an equal sensitivity to the neutral red uptake assay at specific time points. Furthermore, because the RT-CES system provides real-time information regarding the state of cell morphology and adhesion in addition to cell number, we were able to discern a previously unreported effect of arsenic on NIH 3T3 cells prior to cell death. Also, using the RT-CES system, we were able to monitor cytotoxicity effects that occur within a minute of compound addition. Taken together, the RT-CES system allows for real-time, continuous monitoring and quantitative recording of the whole assay process and provides new insight into the cell-toxicant interaction.

Animals↗

Label-free, real-time monitoring of IgE-mediated mast cell activation on microelectronic cell sensor arrays.

Immunoglobulin E (IgE)-mediated mast cell activation is involved in the immediate phase of allergic reactions and plays a central role in the onslaught and persistence of allergic diseases. IgE-mediated mast cell activation includes two important events: cell sensitization resulting from IgE binding to Fc (FcepsilonRI) receptor and cell activation triggered by allergen-mediated oligomerization of membrane-bound IgE. Real-time monitoring of these events is needed to dissect the molecular mechanisms underlying IgE-mediated mast cell activation. Existing technologies are limited to label-based end-point assay formats, which detect either early signaling or final phase of mast cell activation. We describe a microelectronic cell sensor-based technology allowing dynamic monitoring of IgE-mediated mast cell sensitization and activation in real-time without any labeling steps. RBL-2H3 mast cells were cultured onto the surface of microelectronic cell sensor arrays integrated into the bottom of microtiter plates, which record electric properties, such as impedance between cell membrane and sensor surface. In the presence of the allergen, dinitrophenyl (DNP)-bovine serum albumin (BSA), anti-DNP IgE-sensitized cells were activated within 5 min and the entire activation process was quantitatively and continuously recorded. Impedance measurements correlate with morphological dynamics and mediator release as measured by beta-hexosaminidase activity, and can be blocked by pharmacological agents, inhibiting IgE-mediated signaling. The assay on microelectronic cell sensor arrays can be scaled up for high-throughput screening of pharmacological inhibitors of IgE-mediated mast cell activation and other cell-based receptor-ligand assays.

Cell Degranulation↗

Multiplexed, targeted gene expression profiling and genetic analysis on electronic microarrays.

BACKGROUND: Electronic microarrays comprise independent microelectrode test sites that can be electronically biased positive or negative, or left neutral, to move and concentrate charged molecules such as DNA and RNA to one or more test sites. We developed a protocol for multiplexed gene expression profiling of mRNA targets that uses electronic field-facilitated hybridization on electronic microarrays. METHODS: A multiplexed, T7 RNA polymerase-mediated amplification method was used for expression profiling of target mRNAs from total cellular RNA; targets were detected by hybridization to sequence-specific capture oligonucleotides on electronic microarrays. Activation of individual test sites on the electronic microarray was used to target hybridization to designated subsets of sites and allow comparisons of target concentrations in different samples. We used multiplexed amplification and electronic field-facilitated hybridization to analyze expression of a model set of 10 target genes in the U937 cell line during lipopolysaccharide-mediated differentiation. Performance of multiple genetic analyses (single-nucleotide polymorphism detection, gene expression profiling, and splicing isoform detection) on a single electronic microarray was demonstrated using the ApoE and ApoER2 genes as a model system. RESULTS: Targets were detected after a 2-min hybridization reaction. With noncomplementary capture probes, no signal was detectable. Twofold changes in target concentration were detectable throughout the ( approximately 64-fold) range of concentrations tested. Levels of 10 targets were analyzed side by side across seven time points. By confining electronic activation to subsets of test sites, polymorphism detection, expression profiling, and splicing isoform analysis were performed on a single electronic microarray. CONCLUSIONS: Microelectronic array technology provides specific target detection and quantification with advantages over currently available methodologies for targeted gene expression profiling and combinatorial genomics testing.

Alternative Splicing↗