PubMed Health⌕ Search

Biomedical subjects

Joaquim A Nóbrega

Publications and source records attributed to Joaquim A Nóbrega.

5 recordsLinked to original sources

Fraunhofer effect atomic absorption spectrometry.

The dark lines in the solar spectrum were discovered by Wollaston and cataloged by Fraunhofer in the early days of the 19th century. Some years later, Kirchhoff explained the appearance of the dark lines: the sun was acting as a continuum light source and metals in the ground state in its atmosphere were absorbing characteristic narrow regions of the spectrum. This discovery eventually spawned atomic absorption spectrometry, which became a routine technique for chemical analysis in the mid-20th century. Laboratory-based atomic absorption spectrometers differ from the original observation of the Fraunhofer lines because they have always employed a separate light source and atomizer. This article describes a novel atomic absorption device that employs a single source, the tungsten coil, as both the generator of continuum radiation and the atomizer of the analytes. A 25-microL aliquot of sample is placed on the tungsten filament removed from a commercially available 150-W light bulb. The solution is dried and ashed by applying low currents to the coil in a three-step procedure. Full power is then applied to the coil for a brief period. During this time, the coil produces white light, which may be absorbed by any metals present in the atomization cloud produced by the sample. A high-resolution spectrometer with a charge-coupled device detector monitors the emission spectrum of the coil, which includes the dark lines from the metals. Detection limits are reported for seven elements: 5 pg of Ca (422.7 nm); 2 ng of Co (352.7 nm); 200 pg of Cr (425.4 nm); 7 pg of Sr (460.7 nm); 100 pg of Yb (398.8 nm); 500 pg of Mn (403.1 nm); and 500 pg of K (404.4 nm). Simultaneous multielement analyses are possible within a 4-nm spectral window. The relative standard deviations for the seven metals are below 8% for all metals except for Ca (10.7%), which was present in the blank at measurable levels. Analysis of a standard reference material (drinking water) resulted in a mean percent recovery of 91%. This report attempts to give an historical perspective on the development of a novel atomic spectrometer based on the Fraunhofer effect.

Journal Article↗

Analytical characteristics of a continuum-source tungsten coil atomic absorption spectrometer.

A continuum-source tungsten coil electrothermal atomic absorption spectrometer has been assembled, evaluated, and employed in four different applications. The instrument consists of a xenon arc lamp light source, a tungsten coil atomizer, a Czerny-Turner high resolution monochromator, and a linear photodiode array detector. This instrument provides simultaneous multi-element analyses across a 4 nm spectral window with a resolution of 0.024 nm. Such a device might be useful in many different types of analyses. To demonstrate this broad appeal, four very different applications have been evaluated. First of all, the temperature of the gas phase was measured during the atomization cycle of the tungsten coil, using tin as a thermometric element. Secondly, a summation approach for two absorption lines for aluminum falling within the same spectral window (305.5-309.5 nm) was evaluated. This approach improves the sensitivity without requiring any additional preconcentration steps. The third application describes a background subtraction technique, as it is applied to the analysis of an oil emulsion sample. Finally, interference effects caused by Na on the atomization of Pb were studied. The simultaneous measurements of Pb and Na suggests that negative interference arises at least partially from competition between Pb and Na atoms for H2 in the gas phase.

Journal Article↗

Microwave-assisted Acid decomposition of animal- and plant-derived samples for element analysis.

A single microwave-assisted acid-decomposition procedure is proposed for sample preparation of plant- and bovine-derived materials prior to multielement determination by inductively coupled plasma-optical emission spectrometry (ICP-OES). The procedure involved sample grinding in a cryogenic mill to reduce particle sizes and increase the surface area for acid attack, followed by decomposition under high pressure and temperature. A single heating program was employed and efficiently destroyed most of the organic matrix by using small volumes of nitric acid and hydrogen peroxide. Accuracy of the elemental analysis was indicated by the good agreement between certified and found values of elements in plant and animal samples at 95% confidence level. The sample preparation procedure was fast and reproducible, and proved to be efficient for elemental analysis in agricultural and food-related samples by a sensitive multielement technique such as ICP-OES.

Animals↗

Evaluation and application of bismuth as an internal standard for the determination of lead in wines by simultaneous electrothermal atomic absorption spectrometry.

A method for the direct determination of Pb in wines by simultaneous multi-element atomic absorption spectrometry (SIMAAS) using a transversely heated graphite atomizer, Zeeman-effect background corrector and internal standardization is proposed. Bismuth was used as an internal standard and Pd(NO3)2 plus Mg(NO3)2 as chemical modifier to stabilize both the analyte and the internal standard. The implementation of two pyrolysis steps avoided any build-up of carbonaceous residues on the graphite platform. All diluted samples (1 + 1 v/v) in 0.2% v/v HNO3 and reference solutions (5.0-50 microg l(-1) Pb in 0.2% v/v HNO3) were spiked with 25 microg l(-1) Bi. For a 20 microl aliquot dispensed into the graphite tube, a good correlation (r = 0.9997) was obtained between the ratio of the analyte signal to the internal standard signal and the analyte concentration of the reference solutions. The electrothermal behaviour of Pb and Bi in red, white and rosé wines were compared. In addition, absorbance variations due to changes in experimental conditions, such as atomizer temperature, integration time, injected sample volume, radiation beam intensity, graphite tube surface, dilution and sample composition, were minimized by using Bi as internal standard. Relative standard deviations of measurements based on integrated absorbance varied from 0.1 to 3.4% and from 0.5 to 7.3% (n = 12) with and without internal standard correction, respectively. Good recoveries (91-104%) for Pb spikes were obtained. The characteristic mass was 45 pg Pb and the limit of detection based on integrated absorbance was 0.9 microg l(-1) Pb. Internal standardization increased the lifetime of the tube by 25%. Direct determinations of Pb in wines with and without internal standardization approaches were in agreement at the 95% confidence level. The repeatability and the tube lifetime were improved when using Bi as internal standard. The improvement in accuracy using an internal standard was only observed when the analytical results were affected by errors.

Bismuth↗

Comparison of heating extraction procedures for Al, Ca, Mg, and Mn in tea samples.

A focused-microwave-assisted procedure was adopted for the extraction of Al, Ca, Mg, and Mn in tea leaves. The efficiency of extraction was evaluated using diluted acids and a water-soluble alkaline tertiary-amines solution. The extraction procedure was implemented in 5 min. A conventional hot-plate digestion procedure was employed for a comparison. A colorless digest was obtained for all tea samples and the total contents determined for each analyte were employed for estimating the efficiency of extraction. Tea infusions were also prepared. Subsequent determinations of Al, Ca, Mg, and Mn were carried out using flame atomic absorption spectrophotometry (FAAS) and inductively coupled plasma optical emission spectrometry (ICP-OES). In most cases, quantitative, or at least semi-quantitative, extractions were attained for Ca, Mg, and Mn. Lower recoveries were attained to Al, which seems to be related to compounds that bind this element in the sample matrix. Large variations in the trace-element composition of teas were observed; these results are discussed with reference to both extraction media and type of tea.

Aluminum↗