PubMed Health⌕ Search

Biomedical subjects

Jochen Sticher

Publications and source records attributed to Jochen Sticher.

2 recordsLinked to original sources

Computerize anesthesia record keeping in thoracic surgery--suitability of electronic anesthesia records in evaluating predictors for hypoxemia during one-lung ventilation.

OBJECTIVE: The aim of this retrospective study was to assess the suitability of routine data gathered with a computerized anesthesia record keeping system in investigating predictors for intraoperative hypoxemia (SpO2 < 90%) during one-lung ventilation (OLV) in pulmonary surgery. METHODS: Over a four-year period data of 705 patients undergoing thoracic surgery (pneumonectomy: 78; lobectomy: 292; minor pulmonary resections: 335) were recorded online using an automated anesthesia record-keeping system. Twenty-six patient-related, surgery-related and anesthesia-related variables were studied for a possible association with the occurrence of intraoperative hypoxemia during OLV. Data were analyzed using univariate and multivariate (logistic regression) analysis (p < 0.05). The model's discriminative power on hypoxemia was checked with a receiver operating characteristic (ROC) curve. Calibration was tested using the Hosmer-Lemeshow goodness-of-fit test. RESULTS: An intraoperative incidence of hypoxemia during OLV was found in 67 patients (9.5%). Using logistic regression with a forward stepwise algorithm, body-mass-index (BMI, p = 0.018) and preoperative existing pneumonia (p = 0.043) could be detected as independent predictors having an influence on the incidence of hypoxemia during OLV. An acceptable goodness-of-fit could be observed using cross validation for the model (C = 8.21, p = 0.370, degrees of freedom, df 8; H = 3.21, p = 0.350, df 3), the discriminative power was poor with an area under the ROC curve of 0.58 [0.51-0.66]. CONCLUSIONS: In contrast to conventional performed retrospective studies, data were directly available for analyses without any manual intervention. Due to incomplete information and imprecise definitions of parameters, data of computerized anesthesia records collected in routine are helpful but not satisfactory in evaluating risk factors for hypoxemia during OLV.

Adult↗

Small-dose nitric oxide improves oxygenation during one-lung ventilation: an experimental study.

UNLABELLED: Inhaled nitric oxide (NO) at 20 or 40 ppm does not improve arterial oxygenation during one-lung ventilation (OLV). The authors hypothesized that NO at smaller concentrations might improve oxygenation. Twelve piglets weighing 26 to 32 kg were studied. When PaO(2) had reached a plateau during OLV, NO at doses of 4, 8, 16, and 32 ppm were randomly administered for 30 min. Hemodynamic data were determined by invasive monitoring. Blood gas analysis and, in six animals, ventilation-perfusion analysis by the multiple inert gas elimination technique were used to characterize pulmonary gas exchange. NO at 4, 8, 16, and 32 ppm improved PaO(2) during OLV. NO at 4 ppm had a more intense effect on arterial oxygenation than doses of 8, 16, and 32 ppm (DeltaPaO(2), 42 +/- 35 mm Hg versus 22 +/- 20 mm Hg, 13 +/- 18 mm Hg, and 15 +/- 16 mm Hg; P < 0.05). NO at 4 ppm reduced intrapulmonary shunt flow, whereas a larger concentration exhibited no statistically significant effect. The authors conclude that NO improves arterial oxygenation more effectively at smaller doses than at larger doses. This dose-dependent effect remains to be confirmed in acute hypoxemia during OLV. IMPLICATIONS: Inhaled nitric oxide at 4 ppm improves arterial oxygenation during one-lung ventilation to a greater extent than larger doses, and this effect is caused by a reduction in intrapulmonary shunt.

Animals↗