PubMed Health⌕ Search

Biomedical subjects

Jochen Vogl

Publications and source records attributed to Jochen Vogl.

3 recordsLinked to original sources

The need for new SI-traceable magnesium isotopic reference materials.

Recent measurements revealed that commercial magnesium standard solutions showed isotopic abundance variations, which cannot clearly be distinguished from each other by calibrating against the only available isotopic reference material, SRM 980, or reference materials made from SRM 980 like IRMM-009. Therefore new SI-traceable magnesium isotopic reference materials are required.

Environmental Monitoring↗

Comparison of urinary monitoring, faecal monitoring and erythrocyte analysis of stable isotope labels to determine magnesium absorption in human subjects.

We have evaluated urinary monitoring and erythrocyte analysis to determine Mg absorption in human subjects as alternatives to the conventional technique of faecal monitoring by stable-isotope techniques. Ten healthy adults received 2.2 mmol (25)Mg in water, together with wheat bread, followed 15 min later by intravenous injection of 0.6 mmol (26)Mg (day 1). Brilliant blue and Yb (given on day 0 and day 1 respectively) served as qualitative and quantitative faecal markers. Urine was collected for 6 d after test meal intake. Complete collections of faeces were made until excretion of the second brilliant blue marker (given on day 7). Mg isotope ratios were determined by thermal ionisation-MS in urine and faeces and by inductively coupled plasma-MS in erythrocytes. Absorption was determined based on: (1) 6 d urine pools; (2) 24 h urine pools (collected 22-46 h after test meal intake); (3) erythrocytes from a blood sample drawn on day 14; (4) complete 6 d faecal pools; (5) faecal pools based on the first three consecutive stools after excretion of the first brilliant blue marker. Differences in mean Mg absorption (42 44 %) were statistically insignificant between techniques, except when based on 6 d urine pools for which the value was significantly lower (33 (sd 7) %, P=0.0003, ANOVA). The results indicate that Mg absorption can be determined from 24 h urine pools or erythrocytes obtained 14 d after test meal intake, an alternative method to the more time-consuming and labour-intense faecal monitoring. The choice of technique depends on practical and financial considerations.

Absorption↗

Measurements of sulfur in oil using a pressurised wet digestion technique in open vessels and isotope dilution mass spectrometry.

Graz University of Technology has developed a new technique for digesting samples using the well-established high-pressure asher (HPA) from Anton Paar GmbH (Graz, Austria). The digestion is performed in semi-open vessels inside a pressurised autoclave. The new HPA equipment consists of a liner for the autoclave, special sample racks and 30-mL digestion vessels made of quartz, covered with PTFE stoppers. The Laboratory for Isotope Dilution and Nuclear Analysis of the Federal Institute for Materials Research and Testing (BAM, Berlin) tested this new equipment in order to assess its usability for the decomposition of larger sample amounts of gas oils for the measurement of sulfur. Several experiments were carried out using the new sample decomposition technique. In order to test the recovery of the new digestion method, a gas oil material with known sulfur content was chosen, quantified by the validated conventional closed vessel HPA digestion in combination with thermal ionisation mass spectrometry. Isotope dilution mass spectrometry has been applied as analytical method in this investigation. The gas oil was spiked with an isotopic spike material, which is enriched in (34)S, and was then wet digested in the HPA. The oxidized sulfur of the dried samples was reduced to H(2)S and precipitated as As(2)S(3). The sulfur was measured as arsenic monosulfide (AsS(+)). The mass content of sulfur in the gas oil tested is 453.5 mg kg(-1). Recovery tests for increasing masses of gas oils indicate that the recovery using the new measurement technique decreases with increasing mass of gas oil. Results were obtained for approximately 0.3 g sample weight and had less overlap with the result of the old HPA method within the stated uncertainties. At approximately 0.5 g sample weight the yield decreases to about 97% and at approximately 1.0 g sample weight to about 87%. In comparison with the conventional closed vessel HPA digestion, the new technique shows no clear advantages for the certification of the sulfur content in gas oil other than a more convenient handling. The total uncertainty of the sulfur mass fractions (k=2) is about 1.5%. Repeated determination of the oil samples show a relative standard deviation of about 0.8% and indicate that the analytical procedure is robust and reproducible. The demonstrated reproducibility allows the establishment of correction factors for the yield, which in turn enables higher sample masses for routine work. The blank level (0.26 x 10(-6) g) was within the range of the conventional closed HPA digestion procedure.(0.28 x 10(-6) g). Cross contamination could not be detected. In terms of trace metal analysis a good applicability and more advantages over the conventional closed vessel HPA digestion can be assumed.

Journal Article↗