PubMed Health⌕ Search

Biomedical subjects

Joel E Gray

Publications and source records attributed to Joel E Gray.

5 recordsLinked to original sources

Reference values for diagnostic radiology: application and impact.

Reference values (RVs) are recommended by the American Association of Physicists in Medicine for four radiographic projections, computed tomography, fluoroscopy, and dental radiography. RVs are used to compare radiation doses from individual pieces of radiographic equipment with doses from similar equipment assessed in national surveys. RVs recommended by the American Association of Physicists in Medicine have been developed from the Nationwide Evaluation of X-ray Trends survey performed by the state radiation protection agencies with the cooperation and support of the U.S. Food and Drug Administration, the Conference of Radiation Control Program Directors, and the American College of Radiology. The RVs selected by the American Association of Physicists in Medicine represent, approximately, the 80th percentile of the survey distributions. Consequently, equipment exceeding the RVs is using higher radiation doses than is 80% of the equipment in the surveys. Radiation doses for specific projections, with standard phantoms, should be measured annually, as recommended by the American College of Radiology. When the RVs are exceeded, the medical physicist should investigate the cause and determine, in cooperation with the responsible radiologist, whether these doses are justified or the imaging system should be optimized to reduce patient radiation doses. RVs are a useful tool for comparing patient radiation doses at institutions throughout the United States and for providing information about radiographic equipment performance.

Equipment Safety↗

Radiation protection standards: their evolution from science to philosophy.

The concept of applying constraints on individual sources to a small fraction of the public dose limit has been deemed inappropriate when shielding the medical X-ray sources. This represents a broad-based consensus of medical physics and radiological societies in the United States, and the report series on the shielding design for medical X-ray sources (including dental, X-ray imaging and therapeutic X ray) from the National Council on Radiation Protection and Measurements (NCRP) utilises 1 mSv y(-1) as a source control limit. In the present study, the rationale for such a conclusion is discussed, and a somewhat critical look at the current model of radiation protection of the public is made.

Environmental Exposure↗

Important changes in medical x-ray imaging facility shielding design methodology. A brief summary of recommendations in NCRP Report No. 147.

The recently published Report No. 147 of The National Council on Radiation Protection and Measurements entitled "Structural shielding design for medical x-ray imaging facilities" provides an update of shielding recommendations for x rays used for medical imaging. The goal of this report is to ensure that the shielding in these facilities limits radiation exposures to employees and members of the public to acceptable levels. Board certified medical and health physicists, as defined in this report, are the "qualified experts" who are competent to design radiation shielding for these facilities. As such, physicists must be aware of the new technical information and the changes from previous reports that Report No. 147 supersedes. In this article we summarize the new data, models and recommendations for the design of radiation barriers in medical imaging facilities that are presented in Report No. 147.

Biophysical Phenomena↗