PubMed Health⌕ Search

Biomedical subjects

Joel G Fletcher

Publications and source records attributed to Joel G Fletcher.

At least 19 recordsLinked to original sources

Clinical Trial: Effectiveness and Safety of a Novel Anal Insert Device for Treatment of Faecal Incontinence.

BACKGROUND: Treatment options for medically-refractory faecal incontinence (FI)-including anorectal biofeedback, dextranomer injection, and sacral nerve stimulation-are limited and outcomes are often suboptimal. Anal or vaginal insert devices are infrequently used. AIMS: We evaluated the safety and effectiveness of a new anal insert device (StaySure) in patients with FI. METHODS: Patients with FI for&#x2009;&#x2265;&#x2009;6&#x2009;months and&#x2009;&#x2265;&#x2009;4 moderate or large FI episodes during a 4-week baseline entered a 2-4&#x2009;week fitting/run-in period to individualise device size (10 or 13&#x2009;mm) followed by a 4-week treatment period. Outcomes included effectiveness, safety, and quality of life (QoL). The primary outcome was the proportion achieving a&#x2009;&#x2265;&#x2009;50% reduction in FI frequency. RESULTS: Of 124 enrolled patients, 98, 71, and 61 progressed through the baseline, fitting/run-in, and treatment phases respectively, with few exclusions due to device intolerance. In the intent-to-treat cohort of 59 participants (93% women), mean (SD) number of days with FI declined from 13.2 (7.0) to 6.3 (6.9), and FI weekly episodes declined from 5.4 (6.9) to 2.1 (5.1) (69% reduction; p&#x2009;<&#x2009;0.001) with similar results for both device sizes. The primary endpoint was achieved in 76.3% of participants; 54.2% achieved&#x2009;&#x2265;&#x2009;75% reduction. The FIQoL overall score increased from a mean (SD) of 1.9 (0.6) to 2.3 (0.6) (p&#x2009;<&#x2009;0.001), indicating improved QoL. Improvements in FI frequency, FIQoL exceeded minimal clinically important difference thresholds, confirming clear clinical benefit. No treatment-related serious adverse events were reported. CONCLUSIONS: The StaySure anal insert device is safe, well tolerated, and effective in reducing FI in patients with moderate to severe symptoms refractory to conservative therapies. TRIAL REGISTRATION: ClinicalTrials.gov identifier: NCT03898778.

Adult↗

Renal involvement in patients with autoimmune pancreatitis: CT and MR imaging findings.

PURPOSE: To retrospectively evaluate computed tomographic (CT) and magnetic resonance (MR) imaging renal findings at clinical presentation, during treatment, and at follow-up in patients with autoimmune pancreatitis (AIP). MATERIALS AND METHODS: This HIPAA-compliant study received institutional review board approval. All patients included had previously consented to the use of their medical records for the purpose of research. Forty-five patients (38 male and seven female patients; mean age, 64 years) with diagnosis of AIP were included. Forty patients underwent CT or MR imaging at clinical presentation; 33 patients (including five without imaging at presentation) underwent follow-up. CT and MR images were reviewed in consensus by two radiologists for the presence of renal involvement. Various features were evaluated. Clinical characteristics at presentation were compared between patients with and patients without renal involvement. RESULTS: Of the 40 patients who underwent imaging at presentation, 14 (35%) had renal involvement (12 with parenchymal involvement and five with extraparenchymal involvement). Renal parenchymal lesions showed decreased enhancement and appeared as small peripheral cortical nodules, round or wedge-shaped lesions, or diffuse patchy involvement. Thirteen patients with renal involvement at presentation underwent a follow-up study. Renal lesions in 10 patients regressed (in nine, after steroid treatment) but progressed in three patients without steroid treatment. Renal lesions were found in two other patients during follow-up. No significant difference in the clinical characteristics was found between patients with and patients without renal involvement. CONCLUSION: Renal involvement in patients with AIP is relatively common and predominantly involves the cortex of the kidney. The lesions improve after steroid treatment but can progress without steroid treatment.

Adolescent↗

Active Crohn disease: CT findings and interobserver agreement for enteric phase CT enterography.

PURPOSE: To retrospectively evaluate small-bowel enhancement characteristics and the sensitivity, specificity, and interobserver agreement of computed tomographic (CT) findings by using histologic and endoscopic results as a reference standard in patients undergoing enteric phase CT enterography. MATERIALS AND METHODS: The institutional review board approved this retrospective HIPAA-compliant study, which included patients who consented to having their medical records used for research purposes. Enteric phase CT enterographic and ileoscopic findings with or without ileal histologic results were examined in 42 patients (24 women, 18 men). Enteric phase CT enterography was performed after 150 mL of intravenous contrast material was administered at 4 mL/sec, with a 45-second delay. Mural attenuation was measured in the distended and collapsed jejunal and ileal loops and in the terminal ileum. Two radiologists examined CT images for findings of Crohn disease. Mural attenuation for different bowel loops was compared by using a Student t test, with kappa statistics used to measure interobserver agreement and Pearson correleation coefficients used to compare visual and quantitative measures. RESULTS: Distended jejunal loops had significantly greater attenuation than distended ileal loops (113 HU vs 72 HU; P < .001). Attenuation of collapsed jejunal (134 HU) and ileal (108 HU) loops was greater than that of distended jejunal and ileal loops (P < .001). Terminal ileal enhancement was the most sensitive visual CT finding of Crohn disease for both radiologists. Mural thickening demonstrated the greatest interobserver agreement (kappa = 0.83). Visual enhancement and quantitative mural attenuation were significantly correlated (P < .003). CONCLUSION: At enteric phase CT enterography, jejunal attenuation is greater than ileal attenuation and collapsed bowel loops demonstrate greater attenuation than distended bowel loops. Mural hyperenhancement and increased mural thickness are the most sensitive CT findings of active Crohn disease.

Adult↗

Neural ganglia visualized by endoscopic ultrasound.

OBJECTIVES: To describe visualization of gastrointestinal neural ganglia by endoscopic ultrasound (EUS). METHODS: We retrospectively identified patients in whom neural ganglia were visualized during EUS and the diagnosis of ganglion confirmed by EUS guided fine needle aspiration (FNA) cytology. RESULTS: Ten patients were identified. Celiac ganglia were visualized in nine, and a perirectal ganglion was visualized in one. Ganglia appeared as discrete hypoechoic structures, often with associated hypoechoic threads that may represent neural rami. Aspiration of ganglia yielded scant material and caused transient pain. Ganglia were best visualized with linear array echoendoscopes. Celiac ganglia (but not the perirectal ganglion) were retrospectively identified on computed tomography scans. CONCLUSIONS: Gastrointestinal neural ganglia can be imaged by EUS and their identity confirmed by EUS FNA.

Adult↗

Effect of aging on anorectal and pelvic floor functions in females.

PURPOSE: In females, fecal incontinence often is attributed to birth trauma; however, symptoms sometimes begin decades after delivery, suggesting that anorectal sensorimotor functions decline with aging. METHODS: In 61 asymptomatic females (age, 44 +/- 2 years, mean +/- standard error of the mean) without risk factors for anorectal trauma, anal pressures, rectal compliance, and sensation were assessed by manometry, staircase balloon distention, and a visual analog scale during phasic distentions respectively. Anal sphincter appearance and pelvic floor motion also were assessed by static and dynamic magnetic resonance imaging respectively in 38 of 61 females. RESULTS: Aging was associated with lower anal resting (r = -0.44, P < 0.001) and squeeze pressures (r = -0.32, P = 0.01), reduced rectal compliance (i.e., r for pressure at half-maximum volume vs. age = 0.4, P = 0.001), and lower (P <or = 0.002) visual analog scale scores during phasic distentions at 16 (r = -0.5) and 24 mmHg (r = -0.4). Magnetic resonance imaging revealed normal anal sphincters in 29 females and significant sphincter injury, not associated with aging, in 9 females. The location of the anorectal junction at rest (r = 0.52, P < 0.001), squeeze (r = 0.62, P < 0.001), and Valsalva maneuver (r = 0.35, P = 0.03), but not anorectal motion (e.g., from resting to squeeze) was associated with age. CONCLUSIONS: In asymptomatic females, aging is associated with reduced anal resting and squeeze pressures, reduced rectal compliance, reduced rectal sensation, and perineal laxity. Together, these changes may predispose to fecal incontinence in elderly females.

Adult↗

Crohn Disease: mural attenuation and thickness at contrast-enhanced CT Enterography--correlation with endoscopic and histologic findings of inflammation.

PURPOSE: To determine retrospectively if quantitative measures of small-bowel mural attenuation and thickness at computed tomographic (CT) enterography correlate with endoscopic and histologic findings of small-bowel inflammation and to estimate the performance of these measures in predicting inflammatory Crohn disease. MATERIALS AND METHODS: The institutional review board approved this HIPAA-compliant retrospective study, which was conducted with patient informed consent. CT enterography data in 96 patients (31 male patients and 65 female patients) who underwent ileoscopy with or without biopsy were examined for CT signs of active Crohn disease. The most highly enhancing segment of terminal ileum and a normal-appearing ileal loop were identified. After it was confirmed that semiautomated software could accurately measure mural attenuation and thickness, the selected terminal ileal and normal-appearing (control) ileal loops were examined (20 automated measurements at each location) to quantify mural attenuation and wall thickness. Results were compared with endoscopy and histology reports by using logistic regression analysis and receiver operating characteristic curves. RESULTS: Quantitative measures of terminal ileal mural attenuation and wall thickness correlated significantly with active Crohn disease (P < .001). Small-bowel wall thickness was not a significant factor after attenuation was taken into account. A threshold attenuation value with a sensitivity of 90% (18 of 20) for definite Crohn disease (compared with a sensitivity of 80% [16 of 20] for radiologist assessment) was selected. In patients who underwent ileal biopsy, threshold attenuation had a sensitivity identical to that of ileoscopy (81% [26 of 32]; 95% confidence interval: 64%, 93%) in predicting histologic inflammation. CONCLUSION: Quantitative measures of mural attenuation and wall thickness at CT enterography correlate highly with ileoscopic and histologic findings of inflammatory Crohn disease. Quantitative measures of mural attenuation are sensitive markers of small bowel inflammation.

Adolescent↗

CT of small-bowel ischemia associated with obstruction in emergency department patients: diagnostic performance evaluation.

PURPOSE: To retrospectively evaluate the diagnostic performance of computed tomography (CT) for detection of small-bowel ischemia in emergency department patients with abdominal pain and to compare the prospective interpretation with a retrospective interpretation by using surgical or pathologic findings as the reference standard. MATERIALS AND METHODS: The HIPAA-compliant study was approved by the institutional review board, and patients consented to research authorization. Sixty patients (61 examinations) (25 male, 35 female patients; median age, 67 years; range, 0.9-89.7 years) with acute abdominal pain underwent immediate abdominal and pelvic CT and subsequent surgery of the small bowel within 7 days of CT. Prospective radiologic reports were reviewed for diagnosis of small-bowel obstruction and ischemia. Two gastrointestinal radiologists performed blinded, independent, retrospective review of the CT studies with no clinical data other than presence of acute abdominal pain. The reviewers categorized CT signs of obstruction and ischemia and estimated diagnostic certainty. Discordant findings were resolved by consensus review by a third gastrointestinal radiologist. CT interpretations were compared with prospective interpretations and surgical or pathologic findings. Sensitivity and specificity estimates with confidence intervals were calculated. Fisher exact and chi2 tests were used to assess associations between CT signs and the diagnosis of ischemia; kappa statistics were used to estimate agreement between readers. RESULTS: In 27 (44%) of 61 CT studies, small-bowel ischemia was surgically or pathologically confirmed. Sensitivity and specificity for the diagnosis of ischemia were, respectively, 14.8% and 94.1% for prospective interpretations, 29.6% and 91.2% for reader 1, 40.7% and 85.3% for reader 2, and 51.9% and 88.2% for the consensus review. Decreased segmental enhancement was the most specific sign for small-bowel ischemia (P = .001), and its recognition would have improved the diagnostic performance of all readers. There was a significant association of the small-bowel feces sign with the presence of small-bowel ischemia (P = .046). CONCLUSION: Diagnostic performance assessment of CT for the diagnosis of small-bowel ischemia revealed poor prospective interpretation sensitivity.

Abdominal Pain↗

CT colonography using 360-degree virtual dissection: a feasibility study.

OBJECTIVE: Using a 3D rendering technique called "virtual dissection," we sought to evaluate polyp and fold distortion using a colon phantom, estimate the polyp detection performance in humans, and estimate the added benefit of double interpretation and computer-aided diagnosis. MATERIALS AND METHODS: A colon phantom containing 144 polyps of varying sizes (5-12 mm) and shapes (flat, sessile, pedunculated) was scanned. Polyp shape and distortion at virtual dissection were categorized as flame, club, pea, or bizarre. Haustral fold distortion was graded. The CT colonography examinations in 20 consecutive patients (colonoscopically proven normal findings, n = 5; polyps > or = 1 cm, n = 17 in 15 patients) were blindly reviewed by three radiologists using the virtual dissection technique. The added benefits of double interpretation and computer-aided diagnosis were tabulated. RESULTS: Sessile polyps appeared flame (35/48 [73%]) or pea (11/48 [23%]) in shape. Flat polyps appeared flame-shaped (31/47 [66%]) or pea-shaped (16/47 [34%]). Pedunculated polyps were flame (15/45 [33%]), club (20/45 [44%]), or pea (6/45 [13%]) in shape. Axial distortion occurred along the longitudinal axis. The sensitivities of the three observers for polyps of 1 cm or more were 16/17 (94%), 14/17 (82%), and 15/17 (88%). The specificities were 5/5 (100%), 5/5 (100%), and 4/5 (80%). Sensitivities after double interpretation and computer-aided diagnosis improved but did not reach statistical significance. CONCLUSION: Although distortion of colonic structures exists at virtual dissection, it does so in recognizable patterns, so that sensitivity for polyp detection is not compromised.

Aged↗

Occult colorectal polyps on CT colonography: implications for surveillance.

OBJECTIVE: Our purpose was to determine the prevalence of polyps that are invisible on CT colonography (CTC) in a population previously screened for colorectal neoplasms. Differences in the prevalence of occult polyps in various populations might help explain the discordant reported sensitivities for polyp detection in published reports of CTC. SUBJECTS AND METHODS: Seventy-five consecutive patients who had been previously screened for polyps underwent same-day colonoscopy and CTC. Many of the patients had personal histories of previous polypectomies and were undergoing surveillance colonoscopy. The scans were interpreted prospectively by an experienced radiologist. Polyps missed prospectively on CTC were analyzed retrospectively by three experienced radiologists and categorized as perception errors (visible in retrospect), technical errors (e.g., obscured by feces or fluid), or occult (invisible). RESULTS: Thirty polyps 5 mm or larger were found at colonoscopy, 18 of which were missed prospectively on CTC. Of the 18 missed polyps, 12 could not be identified in retrospect, even though they were located in clean, dry, well-distended colonic segments. These were classified as occult. Ten of the 12 occult polyps showed flat morphology on review of colonoscopy video recordings. Of the remaining six missed polyps, two were classified as perception errors, two as technical errors, and two as a combination of technical and perception error. CONCLUSION: In this population, colonographically occult polyps were common and accounted for more detection failures than perception errors and technical errors combined. The high prevalence of occult polyps may be explained by the fact that previous screening may have led to removal of easy-to-see polyps, creating a study population with a higher percentage of hard-to-see polyps.

Aged↗

Nonradiologists as second readers for intraluminal findings at CT colonography.

RATIONALE AND OBJECTIVES: Multiple trials have documented wide interobserver variability between radiologists interpreting computed tomography colonography (CTC) exams. We sought to determine if nonradiologists could learn to interpret intraluminal findings at CTC with a high degree of sensitivity to determine if they could play a role as second readers in interpreting CTC exams. MATERIALS AND METHODS: Seven nonradiologists (five medical students, two radiologic technologists) undertook self-directed CTC training using a teaching file of 50 cases; thereafter, each reader blindly interpreted 50 cases with colonoscopic correlation (30 positive, 20 negative). Results were compared with a previously studied cohort of radiologists. The two technologists additionally repeated the exam after 6 weeks of clinical experience. RESULTS: The sensitivity of nonradiologists for small (5-9 mm) polyps, large (>9 mm) lesions, and cancers was similar to that of radiologists (0.45 versus 0.63, 0.74 versus 0.71, and 0.80 versus 0.88, respectively). After 6 weeks of clinical experience as second readers, the accuracy of one technologist significantly improved (from 74% to 90%, P = .008), whereas accuracy of the other tended toward improvement (from 74% to 86%%, P = .25). Nonradiologists detected, on average, 6/36 additional polyps (17%) missed by any radiologist, and the sensitivity of 5/7 nonradiologists was significantly greater than at least one of the radiologists (P = .05). CONCLUSION: Nonradiologists can perform similarly to radiologists in interpreting intraluminal findings at CTC, with nonradiologist performance improving even after experience with more than 100 cases. Skilled nonradiologists may play a vital role as a second reader of intraluminal findings or by performing quality control of examinations before patient dismissal.

Cohort Studies↗

Phenotypic variation in functional disorders of defecation.

BACKGROUND & AIMS: Although obstructed defecation is generally attributed to pelvic floor dyssynergia, clinical observations suggest a wider spectrum of anorectal disturbances. Our aim was to characterize phenotypic variability in constipated patients by anorectal assessments. METHODS: Anal pressures, rectal balloon expulsion, rectal sensation, and pelvic floor structure (by endoanal magnetic resonance imaging) and motion (by dynamic magnetic resonance imaging) were assessed in 52 constipated women and 41 age-matched asymptomatic women. Phenotypes were characterized in patients by principal components analysis of these measurements. RESULTS: Among patients, 16 had a hypertensive anal sphincter, 41 had an abnormal rectal balloon expulsion test, and 20 had abnormal rectal sensation. Forty-nine patients (94%) had abnormal pelvic floor motion during evacuation and/or squeeze. After correcting for age and body mass index, 3 principal components explained 71% of variance between patients. These factors were weighted most strongly by perineal descent during evacuation (factor 1), anorectal location at rest (factor 2), and anal resting pressure (factor 3). Factors 1 and 3 discriminated between controls and patients. Compared with patients with normal (n = 23) or reduced (n = 18) perineal descent, patients with increased (n = 11) descent were more likely (P < or = .01) to be obese, have an anal resting pressure >90 mm Hg, and have a normal rectal balloon expulsion test result. CONCLUSIONS: These observations demonstrate that functional defecation disorders comprise a heterogeneous entity that can be subcharacterized by perineal descent during defecation, perineal location at rest, and anal resting pressure. Further studies are needed to ascertain if the phenotypes reflect differences in the natural history of these disorders.

Adult↗

State-of-the-art imaging with 64-channel multidetector CT angiography.

During the past decade, computed tomography angiography (CTA) has become a standard noninvasive imaging method for the depiction of vascular anatomy and pathology. The quality and speed of CTA examinations have increased dramatically as CT technology has evolved from single-channel spiral CT systems (circa 1990) to multichannel (4-, 8-, 10-, and 16-slice) spiral CT systems (circa 1998 through 2001). In 2004, 64-slice multichannel CT technology became available in the United States, with the first installation occurring at the Mayo Clinic College of Medicine. We describe our initial experience using this state-of-the art technology, focusing on examinations that illustrate the increased diagnostic resolution of vascular anatomy and pathology, and the effectiveness of 2-and 3-dimensional postprocessing using a 64-channel CT system. Future applications of 64-channel technology for preoperative and postoperative vascular surgery and endovascular techniques are also described.

Angiography↗

The natural history of the incidentally discovered small simple pancreatic cyst: long-term follow-up and clinical implications.

OBJECTIVE: The purpose of our study was to determine the natural history of small (</= 2 cm) simple pancreatic cystic lesions. MATERIALS AND METHODS: A retrospective review was performed of patients with long-term follow-up who were diagnosed with small (</= 2 cm) simple pancreatic cysts on sonography or CT from 1985 to 1996. Long-term surveillance included radiographic surveillance of 5 years or longer, clinical follow-up of 8 years or longer, or response to questionnaire or telephone inquiry 8 year or longer after the original diagnosis. Cause of death was recorded for patients who died within 5-8 years of diagnosis. Patients were excluded if a history of pancreatitis or systemic cystic disease existed. RESULTS: Seventy-nine patients had small simple pancreatic cysts. Forty-nine (62%) had adequate radiologic, clinical, or questionnaire follow-up. Of the 22 patients with radiologic follow-up, 13 (59%) had cysts that remained unchanged or became smaller (mean size, 8 mm; mean follow-up, 9 years), and nine (41%) had cysts that enlarged, from a mean of 14 mm to a mean of 26 mm (mean follow-up, 8 years). Of the 27 patients with clinical or questionnaire follow-up (mean follow-up, 10 years), none developed symptomatic pancreatic disease. Eighteen patients (23%) died within 8 years without adequate radiologic follow-up, none of pancreas-related causes. Twelve patients (15%) were lost to follow-up. CONCLUSION: Although small, incidental, simple pancreatic cysts of 2 cm or smaller may enlarge over a prolonged time, morbidity or mortality due to these small simple cysts is extremely unlikely, and observation appears to be a safe management option.

Adolescent↗

Understanding interpretive errors in radiologists learning computed tomography colonography.

RATIONALE AND OBJECTIVES: To determine if interpretive errors in the course of learning CT colonography are secondary to failures in detection or in characterization and determine the types of lesions frequently missed. MATERIALS AND METHODS: Fifteen radiologists completed an electronic CTC training module consisting of two parts: 1) a teaching file demonstrating the varied appearances of polyps, cancers, and pitfalls in interpreting exams; and 2) a test of 50 complete CTC datasets. Following review of each test case, radiologists were asked to indicate if and where a polyp was visualized. The module then showed each neoplasm (if any) located within the dataset. For false negative examinations, radiologists indicated if the lesion was not seen, was seen but interpreted as colonic wall or fold, or was seen but interpreted as stool or fluid. RESULTS: The average sensitivity for sessile, pedunculated, and flat polyps for these novice readers was 76%, 63%, and 32%, respectively. Average sensitivity for all morphologies of cancers (annular, polypoid, flat) was high (93%, 85%, 95%), with 8/11 missed cancers being secondary to failure in detection. The most frequently missed cancer was an annular constricting tumor (5/11). Overall, 55% (73/132) of errors were failures of detection and 45% (59/132) were errors in characterization. CONCLUSION: Radiologists learning CT colonography had slightly more errors of detection than characterization, but this difference was not statistically significant. Flat and pedunculated polyps and annular constricting cancers were the most frequently missed morphologies. Examples of these abnormalities should be emphasized in CTC training programs.

Colonic Neoplasms↗

Calcifying obstructive pancreatitis: a study of intraductal papillary mucinous neoplasm associated with pancreatic calcification.

BACKGROUND AND AIMS: We have observed intraductal papillary mucinous neoplasm (IPMN) associated with pancreatic calcification. The aim of this study is to describe the profile of IPMN associated with calcification and gain insights into the pathogenesis of calcification in IPMN. METHODS: We identified 10 patients with IPMN with pancreatic calcification, of whom 7 underwent pancreatic resection. We reviewed demographic data, history of previous pancreatitis, and radiological and histological features of these patients. RESULTS: In patients with IPMN with calcification (mean age, 65 +/- 12 yr; 50% men), a diagnosis of chronic calcifying pancreatitis was entertained in 5 of 10 patients; 2 patients had undergone previous endoscopic therapy for stone removal. There was no previous history of pancreatitis in 9 of 10 patients. Radiologically, calcifications were seen diffusely throughout the gland in 8 of 10 patients and interpreted as chronic calcific pancreatitis. Although 1 of the 7 patients who underwent resection had diffuse IPMN throughout the gland, 6 patients had IPMN confined to the head or uncinate process (mean size, 2.75 cm; range, 1.1-5 cm). Histologically, 6 of 7 IPMNs were adenomas, and 1 patient had invasive cancer. No patient had intratumoral calcification. All 7 patients had calcification within the main pancreatic duct and/or side branches, often within inspissated mucus. CONCLUSIONS: IPMN associated with pancreatic calcification can lead to misdiagnosis and inappropriate treatment for chronic calcifying pancreatitis. In the absence of intratumoral calcification or a previous history of long-standing chronic pancreatitis, calcification in IPMN likely represents a unique and hitherto unrecognized form of calcifying obstructive pancreatitis caused by prolonged partial obstruction of the pancreatic duct.

Adenocarcinoma, Mucinous↗

Assessment of small bowel Crohn disease: noninvasive peroral CT enterography compared with other imaging methods and endoscopy--feasibility study.

A feasibility study was conducted to evaluate two biphasic computed tomographic (CT) enterography protocols, a noninvasive CT technique with water administered perorally and CT enteroclysis with methylcellulose administered through a nasojejunal tube, in 23 patients known or suspected to have Crohn disease. Results were compared with the results of fluoroscopic small bowel examination and terminal ileoscopy for the detection of active Crohn disease in the terminal ileum. Luminal distention did not differ significantly between the two CT protocols. Arterial phase imaging was noncontributory in 22 of 23 cases. The noninvasive peroral water CT enterography protocol had similar accuracy (12 of 15 cases, 80%) for enabling the detection of active Crohn disease in comparison with CT enteroclysis with nasojejunal tube (seven of eight, 88%) and fluoroscopic small bowel examination (17 of 23, 74%). No fistulas were missed with use of either CT technique. The authors conclude that noninvasive peroral portal venous phase CT enterography with use of water is an accurate and feasible technique for detecting active small bowel inflammation in patients with Crohn disease.

Administration, Oral↗

Computerized tomographic colonography: performance evaluation in a retrospective multicenter setting.

BACKGROUND & AIMS: No multicenter study has been reported evaluating the performance and interobserver variability of computerized tomographic colonography. The aim of this study was to assess the accuracy of computerized tomographic colonography for detecting clinically important colorectal neoplasia (polyps >or=10 mm in diameter) in a multi-institutional study. METHODS: A retrospective study was developed from 341 patients who had computerized tomographic colonography and colonoscopy among 8 medical centers. Colonoscopy and pathology reports provided the standard. A random sample of 117 patients, stratified by criterion standard, was requested. Ninety-three patients were included (47% with polyps >or=10 mm; mean age, 62 years; 56% men; 84% white; 40% reported colorectal symptoms; 74% at increased risk for colorectal cancer). Eighteen radiologists blinded to the criterion standard interpreted computerized tomography colonography examinations, each using 2 of 3 different software display platforms. RESULTS: The average area under the receiver operating characteristic curve for identifying patients with at least 1 lesion >or=10 mm was 0.80 (95% lower confidence bound, 0.74). The average sensitivity and specificity were 75% (95% lower confidence bound, 68%) and 73% (95% lower confidence bound, 66%), respectively. Per-polyp sensitivity was 75%. A trend was observed for better performance with more observer experience. There was no difference in performance across software display platforms. CONCLUSIONS: Computerized tomographic colonography performance compared favorably with reported performance of fecal occult blood testing, flexible sigmoidoscopy, and barium enema. A prospective study evaluating the performance of computerized tomography colonography in a screening population is indicated.

Colonic Neoplasms↗