PubMed Health⌕ Search

Biomedical subjects

Joel G Fletcher

Publications and source records attributed to Joel G Fletcher.

11 recordsLinked to original sources

Clinical Trial: Effectiveness and Safety of a Novel Anal Insert Device for Treatment of Faecal Incontinence.

BACKGROUND: Treatment options for medically-refractory faecal incontinence (FI)-including anorectal biofeedback, dextranomer injection, and sacral nerve stimulation-are limited and outcomes are often suboptimal. Anal or vaginal insert devices are infrequently used. AIMS: We evaluated the safety and effectiveness of a new anal insert device (StaySure) in patients with FI. METHODS: Patients with FI for&#x2009;&#x2265;&#x2009;6&#x2009;months and&#x2009;&#x2265;&#x2009;4 moderate or large FI episodes during a 4-week baseline entered a 2-4&#x2009;week fitting/run-in period to individualise device size (10 or 13&#x2009;mm) followed by a 4-week treatment period. Outcomes included effectiveness, safety, and quality of life (QoL). The primary outcome was the proportion achieving a&#x2009;&#x2265;&#x2009;50% reduction in FI frequency. RESULTS: Of 124 enrolled patients, 98, 71, and 61 progressed through the baseline, fitting/run-in, and treatment phases respectively, with few exclusions due to device intolerance. In the intent-to-treat cohort of 59 participants (93% women), mean (SD) number of days with FI declined from 13.2 (7.0) to 6.3 (6.9), and FI weekly episodes declined from 5.4 (6.9) to 2.1 (5.1) (69% reduction; p&#x2009;<&#x2009;0.001) with similar results for both device sizes. The primary endpoint was achieved in 76.3% of participants; 54.2% achieved&#x2009;&#x2265;&#x2009;75% reduction. The FIQoL overall score increased from a mean (SD) of 1.9 (0.6) to 2.3 (0.6) (p&#x2009;<&#x2009;0.001), indicating improved QoL. Improvements in FI frequency, FIQoL exceeded minimal clinically important difference thresholds, confirming clear clinical benefit. No treatment-related serious adverse events were reported. CONCLUSIONS: The StaySure anal insert device is safe, well tolerated, and effective in reducing FI in patients with moderate to severe symptoms refractory to conservative therapies. TRIAL REGISTRATION: ClinicalTrials.gov identifier: NCT03898778.

Adult↗

Nonradiologists as second readers for intraluminal findings at CT colonography.

RATIONALE AND OBJECTIVES: Multiple trials have documented wide interobserver variability between radiologists interpreting computed tomography colonography (CTC) exams. We sought to determine if nonradiologists could learn to interpret intraluminal findings at CTC with a high degree of sensitivity to determine if they could play a role as second readers in interpreting CTC exams. MATERIALS AND METHODS: Seven nonradiologists (five medical students, two radiologic technologists) undertook self-directed CTC training using a teaching file of 50 cases; thereafter, each reader blindly interpreted 50 cases with colonoscopic correlation (30 positive, 20 negative). Results were compared with a previously studied cohort of radiologists. The two technologists additionally repeated the exam after 6 weeks of clinical experience. RESULTS: The sensitivity of nonradiologists for small (5-9 mm) polyps, large (>9 mm) lesions, and cancers was similar to that of radiologists (0.45 versus 0.63, 0.74 versus 0.71, and 0.80 versus 0.88, respectively). After 6 weeks of clinical experience as second readers, the accuracy of one technologist significantly improved (from 74% to 90%, P = .008), whereas accuracy of the other tended toward improvement (from 74% to 86%%, P = .25). Nonradiologists detected, on average, 6/36 additional polyps (17%) missed by any radiologist, and the sensitivity of 5/7 nonradiologists was significantly greater than at least one of the radiologists (P = .05). CONCLUSION: Nonradiologists can perform similarly to radiologists in interpreting intraluminal findings at CTC, with nonradiologist performance improving even after experience with more than 100 cases. Skilled nonradiologists may play a vital role as a second reader of intraluminal findings or by performing quality control of examinations before patient dismissal.

Cohort Studies↗

The natural history of the incidentally discovered small simple pancreatic cyst: long-term follow-up and clinical implications.

OBJECTIVE: The purpose of our study was to determine the natural history of small (</= 2 cm) simple pancreatic cystic lesions. MATERIALS AND METHODS: A retrospective review was performed of patients with long-term follow-up who were diagnosed with small (</= 2 cm) simple pancreatic cysts on sonography or CT from 1985 to 1996. Long-term surveillance included radiographic surveillance of 5 years or longer, clinical follow-up of 8 years or longer, or response to questionnaire or telephone inquiry 8 year or longer after the original diagnosis. Cause of death was recorded for patients who died within 5-8 years of diagnosis. Patients were excluded if a history of pancreatitis or systemic cystic disease existed. RESULTS: Seventy-nine patients had small simple pancreatic cysts. Forty-nine (62%) had adequate radiologic, clinical, or questionnaire follow-up. Of the 22 patients with radiologic follow-up, 13 (59%) had cysts that remained unchanged or became smaller (mean size, 8 mm; mean follow-up, 9 years), and nine (41%) had cysts that enlarged, from a mean of 14 mm to a mean of 26 mm (mean follow-up, 8 years). Of the 27 patients with clinical or questionnaire follow-up (mean follow-up, 10 years), none developed symptomatic pancreatic disease. Eighteen patients (23%) died within 8 years without adequate radiologic follow-up, none of pancreas-related causes. Twelve patients (15%) were lost to follow-up. CONCLUSION: Although small, incidental, simple pancreatic cysts of 2 cm or smaller may enlarge over a prolonged time, morbidity or mortality due to these small simple cysts is extremely unlikely, and observation appears to be a safe management option.

Adolescent↗

Understanding interpretive errors in radiologists learning computed tomography colonography.

RATIONALE AND OBJECTIVES: To determine if interpretive errors in the course of learning CT colonography are secondary to failures in detection or in characterization and determine the types of lesions frequently missed. MATERIALS AND METHODS: Fifteen radiologists completed an electronic CTC training module consisting of two parts: 1) a teaching file demonstrating the varied appearances of polyps, cancers, and pitfalls in interpreting exams; and 2) a test of 50 complete CTC datasets. Following review of each test case, radiologists were asked to indicate if and where a polyp was visualized. The module then showed each neoplasm (if any) located within the dataset. For false negative examinations, radiologists indicated if the lesion was not seen, was seen but interpreted as colonic wall or fold, or was seen but interpreted as stool or fluid. RESULTS: The average sensitivity for sessile, pedunculated, and flat polyps for these novice readers was 76%, 63%, and 32%, respectively. Average sensitivity for all morphologies of cancers (annular, polypoid, flat) was high (93%, 85%, 95%), with 8/11 missed cancers being secondary to failure in detection. The most frequently missed cancer was an annular constricting tumor (5/11). Overall, 55% (73/132) of errors were failures of detection and 45% (59/132) were errors in characterization. CONCLUSION: Radiologists learning CT colonography had slightly more errors of detection than characterization, but this difference was not statistically significant. Flat and pedunculated polyps and annular constricting cancers were the most frequently missed morphologies. Examples of these abnormalities should be emphasized in CTC training programs.

Colonic Neoplasms↗

Calcifying obstructive pancreatitis: a study of intraductal papillary mucinous neoplasm associated with pancreatic calcification.

BACKGROUND AND AIMS: We have observed intraductal papillary mucinous neoplasm (IPMN) associated with pancreatic calcification. The aim of this study is to describe the profile of IPMN associated with calcification and gain insights into the pathogenesis of calcification in IPMN. METHODS: We identified 10 patients with IPMN with pancreatic calcification, of whom 7 underwent pancreatic resection. We reviewed demographic data, history of previous pancreatitis, and radiological and histological features of these patients. RESULTS: In patients with IPMN with calcification (mean age, 65 +/- 12 yr; 50% men), a diagnosis of chronic calcifying pancreatitis was entertained in 5 of 10 patients; 2 patients had undergone previous endoscopic therapy for stone removal. There was no previous history of pancreatitis in 9 of 10 patients. Radiologically, calcifications were seen diffusely throughout the gland in 8 of 10 patients and interpreted as chronic calcific pancreatitis. Although 1 of the 7 patients who underwent resection had diffuse IPMN throughout the gland, 6 patients had IPMN confined to the head or uncinate process (mean size, 2.75 cm; range, 1.1-5 cm). Histologically, 6 of 7 IPMNs were adenomas, and 1 patient had invasive cancer. No patient had intratumoral calcification. All 7 patients had calcification within the main pancreatic duct and/or side branches, often within inspissated mucus. CONCLUSIONS: IPMN associated with pancreatic calcification can lead to misdiagnosis and inappropriate treatment for chronic calcifying pancreatitis. In the absence of intratumoral calcification or a previous history of long-standing chronic pancreatitis, calcification in IPMN likely represents a unique and hitherto unrecognized form of calcifying obstructive pancreatitis caused by prolonged partial obstruction of the pancreatic duct.

Adenocarcinoma, Mucinous↗

Assessment of small bowel Crohn disease: noninvasive peroral CT enterography compared with other imaging methods and endoscopy--feasibility study.

A feasibility study was conducted to evaluate two biphasic computed tomographic (CT) enterography protocols, a noninvasive CT technique with water administered perorally and CT enteroclysis with methylcellulose administered through a nasojejunal tube, in 23 patients known or suspected to have Crohn disease. Results were compared with the results of fluoroscopic small bowel examination and terminal ileoscopy for the detection of active Crohn disease in the terminal ileum. Luminal distention did not differ significantly between the two CT protocols. Arterial phase imaging was noncontributory in 22 of 23 cases. The noninvasive peroral water CT enterography protocol had similar accuracy (12 of 15 cases, 80%) for enabling the detection of active Crohn disease in comparison with CT enteroclysis with nasojejunal tube (seven of eight, 88%) and fluoroscopic small bowel examination (17 of 23, 74%). No fistulas were missed with use of either CT technique. The authors conclude that noninvasive peroral portal venous phase CT enterography with use of water is an accurate and feasible technique for detecting active small bowel inflammation in patients with Crohn disease.

Administration, Oral↗

Computerized tomographic colonography: performance evaluation in a retrospective multicenter setting.

BACKGROUND & AIMS: No multicenter study has been reported evaluating the performance and interobserver variability of computerized tomographic colonography. The aim of this study was to assess the accuracy of computerized tomographic colonography for detecting clinically important colorectal neoplasia (polyps >or=10 mm in diameter) in a multi-institutional study. METHODS: A retrospective study was developed from 341 patients who had computerized tomographic colonography and colonoscopy among 8 medical centers. Colonoscopy and pathology reports provided the standard. A random sample of 117 patients, stratified by criterion standard, was requested. Ninety-three patients were included (47% with polyps >or=10 mm; mean age, 62 years; 56% men; 84% white; 40% reported colorectal symptoms; 74% at increased risk for colorectal cancer). Eighteen radiologists blinded to the criterion standard interpreted computerized tomography colonography examinations, each using 2 of 3 different software display platforms. RESULTS: The average area under the receiver operating characteristic curve for identifying patients with at least 1 lesion >or=10 mm was 0.80 (95% lower confidence bound, 0.74). The average sensitivity and specificity were 75% (95% lower confidence bound, 68%) and 73% (95% lower confidence bound, 66%), respectively. Per-polyp sensitivity was 75%. A trend was observed for better performance with more observer experience. There was no difference in performance across software display platforms. CONCLUSIONS: Computerized tomographic colonography performance compared favorably with reported performance of fecal occult blood testing, flexible sigmoidoscopy, and barium enema. A prospective study evaluating the performance of computerized tomography colonography in a screening population is indicated.

Colonic Neoplasms↗

Pancreatic malignancy: value of arterial, pancreatic, and hepatic phase imaging with multi-detector row CT.

PURPOSE: To assess the value of arterial, pancreatic, and hepatic phase imaging at multi-detector row computed tomography (CT) of the pancreas for pancreatic malignancy. MATERIALS AND METHODS: Thirty-nine patients suspected of having resectable pancreatic adenocarcinoma underwent triple-phase multi-detector row CT. Images obtained during each phase were interpreted by one radiologist who evaluated presence of tumor, vascular invasion, and flow artifacts in the superior mesenteric vein and measured attenuation of tumor, normal pancreas, aorta, and superior mesenteric vein. Results were compared with histologic, follow-up, and correlative imaging findings. RESULTS: Mean tumor-to-gland attenuation difference was greatest on images obtained in the pancreatic phase (42 HU) versus that on those obtained in the hepatic phase (35 HU) and in the arterial phase (25 HU). For tumor detection, sensitivity of the images obtained in pancreatic (0.97 [29 of 30]) and hepatic (0.93 [28 of 30]) phases was superior to that of those obtained in arterial phase (0.63 [19 of 30]) (P < or =.008). For vascular invasion detection, sensitivity of images obtained in the hepatic phase (0.83) was better than that of those obtained in the pancreatic (0.58) and arterial (0.25) phases. Images obtained in the pancreatic phase demonstrated more flow artifacts and decreased attenuation in the superior mesenteric vein, compared with the artifacts revealed on images obtained in the hepatic phase. CONCLUSION: Routine acquisition of images in the arterial phase is unnecessary for detection of pancreatic adenocarcinoma. Images of the pancreas obtained in the hepatic phase with multi-detector row CT most accurately display vascular invasion.

Adenocarcinoma↗

Diseases of the cecum: a CT pictorial review.

Cecal pathology is commonly encountered and may represent a diagnostic challenge in patients with either acute or chronic clinical presentations. Although appendicitis accounts for the majority of surgical conditions presenting with right lower quadrant pain, readers should be aware of the broad spectrum of cecal pathologies and characteristic CT findings, which can be useful in establishing the correct diagnosis.

Cecal Diseases↗

Primary hepatic angiosarcoma: findings at CT and MR imaging.

PURPOSE: To evaluate and describe cross-sectional imaging findings in patients with pathologically confirmed primary hepatic angiosarcoma. MATERIALS AND METHODS: Findings from imaging examinations in 13 patients with pathologically confirmed primary hepatic angiosarcoma were retrospectively reviewed (computed tomographic [CT] images obtained in 10 patients and magnetic resonance [MR] images obtained in five patients were available for review). Two gastrointestinal radiologists evaluated lesion number, size, attenuation and signal intensity characteristics, and the pattern and degree of contrast material enhancement. Medical records were reviewed for clinical features associated with angiosarcoma. RESULTS: Angiosarcoma appeared as multiple nodules (n = 6), as dominant masses (n = 6), or as a diffusely infiltrating lesion (n = 1). Multiple nodules were hypoattenuating at unenhanced and contrast material--enhanced CT (six of six patients). When dominant masses were encountered at MR imaging, T2-weighted MR imaging demonstrated heterogeneous internal architecture (four of four patients) similar to that of hepatocellular carcinoma. Multiphase contrast-enhanced CT and MR images showed dominant masses to have heterogeneous and progressive enhancement (three of three patients). Clinical features associated with angiosarcoma included splenic metastases (six of 13 patients), thrombocytopenia (seven of 13 patients), disseminated intravascular coagulation (four of 13 patients), and hemolytic anemia (three of 13 patients). CONCLUSION: Primary hepatic angiosarcoma exhibits a spectrum of appearances that reflect its varied pathologic features.

Adult↗