Does continuous flow left ventricular assist device technology have a positive impact on outcome pretransplant and posttransplant?

BACKGROUND: Left ventricular assist devices (LVADs) with continuous flow properties are increasingly used to bridge heart failure patients to cardiac transplantation. Advantages in comparison with the pulsatile LVADs are smaller size, better endurance, and lower thromboembolic events. However, whether these new pumps have similar pre- and posttransplant outcomes is not clear. METHODS: Fifty patients with a continuous flow device (Micromed DeBakey, Houston, TX or InCor BerlinHeart, Berlin, Germany) were compared with an age-, disease-, and LVAD duration-matched control group (n = 80) supported with a pulsatile device (Novacor, WorldHeart, Oakland, CA or HeartMate, Thoratec Corp, Pleasanton, CA). RESULTS: Age (44.3 +/- 13.4 vs 46.1 +/- 11.1 years), disease (idiopathic dilated cardiomyopathy, 58% vs 65%), and LVAD duration (138 +/- 131 vs 128 +/- 106 days) were comparable in both groups. Successful bridging to transplantation was similar with continuous flow in comparison with pulsatile device support (52% vs 56%, p = not significant [NS]). Thirty-day mortality after cardiac transplantation in patients with continuous flow LVAD support was 21.7% vs 22.2% with pulsatile LVADs (p = NS). Reasons for death were similar among the different LVAD groups. Long-term survival was similar in both LVAD groups compared with patients without previous LVAD support. Interestingly, severe rejections were significantly more frequent in patients with a continuous flow LVAD (p < 0.001). CONCLUSIONS: The new generation of cardiac assist devices with continuous flow pattern has a similar rate of pre- and posttransplant mortality in comparison with pulsatile LVADs. However, the rate and severity of posttransplant rejection was significantly higher in the group with continuous flow devices. Further studies are warranted to explain the higher rate of severe rejections.

Adult↗

Reversible pulmonary hypertension in heart transplant candidates: to transplant or not to transplant.

BACKGROUND: Pulmonary hypertension (PHT), defined as a pulmonary vascular resistance (PVR) greater than 2.5 Wood units [WU] and(or) transpulmonary gradient (TPG) greater than 12 mm Hg, is a risk factor for mortality in cardiac transplantation due to elevated postoperative right heart failure. Orthotopic heart transplantation is possible if PVR could be reversed below 2.5 WU and TPG below 12 mm Hg. We show the Muenster experience from the last 10 years. METHODS: From April 1996 to December 2005 all cardiac transplant recipients separated into patients with and without PHT were included. All patients with PHT had successful reduction (PVR < or = 2.5 WU and TPG < or = 12 mm Hg) using prostaglandin I2 or E1. Posttransplant early and late mortality and incidence of right heart failure were studied. RESULTS: Two hundred seventeen patients were included in this study. Of these, 168 had normal pulmonary pressures (non-PHT group), 49 (22.6%) had reversible PHT (rev-PHT group). Mean PVR was 1.6 +/- 1.1 WU vs 2.1 +/- 1.1 WU (p < 0.01; non-PHT vs rev-PHT) and mean TPG 8.0 +/- 1.9 mm Hg vs 10.6 +/- 4.1 mm Hg (p = not significant [NS]). Thirty-day survival after orthotopic cardiac transplantation was 85% vs 78% (p = 0.150) and 10 year survival 63% vs 61% (p = NS). Right heart failure during the first 30 days after transplantation occurred in 27% in the non-PHT group and in 64% in the rev-PHT group (p = 0.035). However, in patients transplanted after 2001 it did not appear. CONCLUSIONS: Cardiac transplant candidates with reversible PHT have still significantly elevated pulmonary pressures compared with patients without PHT. Despite a significantly higher risk of right heart failure, long-term survival after orthotopic cardiac transplantation was not affected.

Adult↗

Left bundle branch block in chronic heart failure-impact on diastolic function, filling pressures, and B-type natriuretic peptide levels.

BACKGROUND: For patients with chronic heart failure (CHF), left bundle branch block (LBBB) is associated with impaired systolic function and increased morbidity and mortality, but data on diastolic function are scarce. In this patient population, we attempted to define the impact of LBBB on diastolic function, filling pressures, and brain natriuretic peptide and its circulating N-terminal precursor (NT-proBNP) levels. METHODS: A total of 94 patients with stable CHF (48 with complete LBBB, 46 without intraventricular conduction delay and normal QRS duration) underwent conventional 2-dimensional/Doppler echocardiography and Doppler tissue analysis of mitral annular velocities. As a measure of left ventricular filling pressures, the ratio of peak early mitral flow velocity to peak early diastolic mitral annular velocity was derived. NT-proBNP measurements were carried out on a bench-top analyzer (Elecsys-2010, Roche Diagnostics, Mannheim, Germany). RESULTS: Patients with or without LBBB did not differ with respect to the cause of CHF or ejection fraction, but in LBBB deceleration time was shorter (163 +/- 66 vs 205 +/- 95 milliseconds, P = .021) and a restrictive mitral filling pattern was more frequent (35% vs 11%, P = .005). In such patients, the ratio of peak early mitral flow velocity to peak early diastolic mitral annular velocity was higher (14.5 +/- 6.2 vs 10.6 +/- 5.2, P < .001) and NT-proBNP was elevated (3553 +/- 3725 vs 850 +/- 896 pg/mL, P < .01) as compared with patients without LBBB. CONCLUSION: For patients with CHF and comparable systolic performance, LBBB is associated with more severe diastolic dysfunction, elevated filling pressures, and higher NT-proBNP levels. These findings may contribute to increased morbidity and mortality of such patients.

Blood Pressure↗

Tissue Doppler imaging in patients with moderate to severe aortic valve stenosis: clinical usefulness and diagnostic accuracy.

BACKGROUND: Mitral annular velocities derived from tissue Doppler imaging (TDI) provide information about left ventricular (LV) long-axis function and allow for the assessment of LV filling pressures in selected subsets of patients. It was the aim of this study to assess the usefulness of TDI in patients with moderate to severe aortic valve stenosis (AS). METHODS: Twenty-three patients with moderate to severe AS (mean aortic valve area 0.8 +/- 0.4 cm2), in whom coronary artery disease had been ruled out, and 36 asymptomatic age-matched control subjects underwent assessment of ejection fraction, fractional shortening, and mitral inflow (E, A, E/A ratio). TDI velocities (S', E', A') were derived from the septal mitral annulus. In patients with AS, LV pressure before atrial contraction (LV pre-A pressure), LV end-diastolic pressure, and cardiac index were measured during cardiac catheterization. RESULTS: In patients with AS, systolic (S') and early diastolic mitral annular velocities (E') were significantly reduced in comparison to control subjects (systolic, 5.5 +/- 1.2 vs 8.3 +/- 1.3 cm/s; early diastolic, 5.6 +/- 1.6 vs 10.2 +/- 3.0 cm/s, P <.001 for both comparisons), but ejection fraction, fractional shortening, and cardiac index were normal. In patients with AS, LV pre-A pressures (14 +/- 4 mm Hg) and end-diastolic pressures were high (19 +/- 7 mm Hg). In such patients, the mitral E/E' ratio was significantly related to LV pre-A pressure (r = 0.75, P <.001) and to LV end-diastolic pressure (r = 0.78, P <.001). In patients with AS, an E/E' ratio > or =13 identified an LV end-diastolic pressure >15 mm Hg, with a sensitivity of 93% and a specificity of 88%. CONCLUSIONS: In patients with moderate to severe AS, TDI allows for a reliable, noninvasive estimation of filling pressures. In such patients, systolic long-axis function is impaired even in the presence of normal ejection fraction and cardiac index. Thus, TDI integrates information about systolic and diastolic performance and may be a useful addition in the echocardiographic workup and care of patients with AS.

Aged↗

Left ventricular pressure and volume unloading during pulsatile versus nonpulsatile left ventricular assist device support.

BACKGROUND: Nonpulsatile axial or centrifugal pumps are the latest generation of left ventricular assist devices (LVAD). Whether left ventricular (LV) unloading and outcome in these devices is similar to pulsatile LVADs during long-term support has not been investigated. We compared LV unloading and mortality between different types of LVAD support (pulsatile versus nonpulsatile). METHODS: In 31 patients undergoing long-term LVAD implantation (nonpulsatile = 10, pulsatile = 21) preoperative and postoperative echocardiographic and hemodynamic assessment with right heart catheterization had been obtained. RESULTS: All patients had similar echocardiographic, hemodynamic, and clinical heart failure characteristics at baseline. The degree of LV pressure unloading was the same in both device types, caused by similar reduction of mean pulmonary pressure (18.6 +/- 5.1 versus 18.3 +/- 7.5 mm Hg) and pulmonary capillary wedge pressure (8.9 +/- 4.4 versus 8.0 +/- 7.0 mm Hg). Left ventricular volume unloading was pronounced with a pulsatile device owing to a statistically significant higher pump output (5.1 +/- 1.0 L/min) in comparison with nonpulsatile LVADs (3.6 +/- 0.9 L/min, p < 0.001). Echocardiographic-determined end-systolic indicators confirm this augmentation in pulsatile LVADs. Etiology or the time interval of hemodynamic reassessment had no impact in left ventricular pressure unloading, but LV volume unloading decreased between day 60 and 120 in patients with nonpulsatile LVADs. The preoperative and postoperative transplant mortality was comparable in both groups. CONCLUSIONS: Left ventricular pressure unloading is similar in patients with nonpulsatile as compared with pulsatile implantable long-term assist devices. Left ventricular volume unloading is pronounced in pulsatile LVADs.

Adolescent↗

Vasoactive peptides during long-term follow-up of patients after cardiac transplantation.

BACKGROUND: Vasoactive peptides are accepted indicators of the degree of heart failure and its progression or improvement following medical therapy. Normalization of cardiac hemodynamics by cardiac transplantation (HTx) may lead to normalization of atrial natriuretic peptide (ANP) and brain natriuretic peptide (BNP) plasma levels shortly after the procedure. METHODS: Long-term follow-up was done for 14 consecutive patients, 12 men and 2 women, 49 years of age (range 24 to 64 years). ANP and BNP were measured by radioimmunoassay (RIA) in central venous plasma samples (before breakfast, at steady state) at the following intervals after HTx: 7 to 30 (1), 31 to 60 (2), 61 to 90 (3), 120 to 180 (4) and 210 to 365 (5) days. RESULTS: During follow-up, ANP decreased significantly within 2 months after HTx and continued of this level, whereas BNP decreased continuously without reaching normal values. The mean ratio of ANP:BNP increased from 3.23 to 8.01 during follow-up. Whereas right atrial pressure (RAP), right ventricular pressure (RVP), right ventricular end-diastolic pressure (RVEDP) and pulmonary capillary wedge pressure (PCWP) did not change during follow-up, cardiac output (CO) improved slightly, but significantly from 5.21 liters/min to 5.9 liters/min (p = 0.035). CONCLUSIONS: Normalization of left ventricular function after orthotopic HTx does not induce an early diminution of ANP and BNP plasma levels to normal concentrations. Although elevated ANP concentrations showed only minimal changes within 1 year, BNP decreased significantly as early as 2 months after HTx, without reaching normal values during the year of follow-up. Also, the ratio of ANP and BNP increased significantly from 3.23 to 8.01. These results demonstrate the contribution of other factors beyond cardiac function that determine the levels of these peptides.

Atrial Natriuretic Factor↗