Operator induced variability in cardiovascular MR: left ventricular measurements and their reproducibility.

PURPOSE: To assess the intra- and inter-operator variability of the manual planning of cardiovascular magnetic resonance imaging and to evaluate the influence of these factors on the functional parameters of the left ventricle (LV). METHOD: The study population consisted of 10 healthy volunteers. For each subject the manual planning of the short-axis cine acquisitions was carried out twice by one operator and once by a second operator. Left ventricular volume, mass, and function were manually evaluated twice by one experienced observer, resulting in an approximation of the intra-observer variability factor. The intra- and inter-operator variation factors were estimated as the difference between the total and intra-observer variation components. RESULTS: LV end-diastolic volume varied by 3.3% and 4.16%, and LV end-systolic volume by 5.84% and 6.23% for intra- and inter-operator studies, respectively. The variability for LV mass at end-diastole was equal to 4.23% in both studies. For the ejection fraction the variability was 3.56% and 2.97% for intra- and inter-operator studies, respectively. Comparison of reproducibility between intra- and inter-operator studies resulted in insignificant statistical differences. Bland-Altman limits of agreements revealed no systematic bias in differences between measurements with respect to their means. Reliability of the planning expressed as the angular deviation of the short-axis imaging planes amounts to 2.67 -/+ 1.5 degrees and 4.99 +/- 2.17 degrees for the intra-operator and inter-operator studies, respectively. For EDV, ESV, and EF approximately 75-80% of the total variation can be explained by the within or between operator variation, while the same percentage is 60% for LVM. CONCLUSIONS: Our study confirms the excellent inter- and intra-operator reproducibility of the cardiovascular magnetic resonance measurements of the left ventricular volumes and mass in a group of healthy volunteers.

Adult↗

Multiview active appearance models for simultaneous segmentation of cardiac 2- and 4-chamber long-axis magnetic resonance images.

RATIONALE AND OBJECTIVES: Long-axis cardiac magnetic resonance (MR) views enable a rapid, online evaluation of cardiac function from only 2 views. In this article, we aimed to evaluate a model-based method for the simultaneous detection of 2- and 4-chamber endocardial and epicardial contours in end-diastolic and end-systolic phases of MR images. METHODS: We introduce multiview Active Appearance Models for the automated segmentation of long-axis cardiac MR images of the left ventricle. Two modes of initialization were used to test the accuracy of the model with minimal user interaction and the best-obtainable accuracy with this model. The segmentation was initialized by annotating 2 points in the base and one in the apex. We tested the method's performance by comparing the point-to-curve errors, ejection fractions, and biplane area-length volumes calculated with the automatically detected contours to those calculated from contours that were annotated manually by experts. Leave-one-out experiments were performed with 2- and 4-chamber long axis MR images of 59 subjects in end-diastolic and end-systolic phases. RESULTS: When initializing in all 4 frames, 97% of the segmentations were successful, and the standard deviation in the volume-errors with respect to the average manually identified volume was 9.0% for the end-diastolic volumes and 15% for the end-systolic volumes. When the method was initialized in the end-systolic frames only, 92% of the segmentations were successful, and the standard deviation in the errors in the volumes with respect to the average manually identified volume was 13.3% for the end-diastolic volumes and 16.7% for the end-systolic volumes. Bland-Altman plots showed that the errors were distributed randomly around 0, and by using a paired t test comparing manual and computer-determined volumes, we were able to detect that the volume differences were not significant. Simultaneous detection of the endocardial and epicardial contours in 2- and 4-chamber views and end-diastolic and end-systolic phases for one subject takes approximately 3 seconds. CONCLUSIONS: The accuracy of the reported method is comparable with the interobserver variability for initialization in all frames and slightly worse than the interobserver variability with initialization in the end-systolic frames only. However, in both cases the errors were not significant. Initialization in end-systolic frames only leads to a statistically insignificantly lower model accuracy; however, it requires only half the user interaction. Therefore, we can conclude that this method enables rapid analysis of the cardiac left ventricular function with little user interaction.

Diastole↗

The influence of flow, vessel diameter, and non-newtonian blood viscosity on the wall shear stress in a carotid bifurcation model for unsteady flow.

OBJECTIVES: The atherosclerotic process in arteries is correlated with the local wall shear stress (WSS). Plaque development particularly occurs in regions with recirculation (ie, where the WSS oscillates). We investigated the effects of non-Newtonian blood viscosity, variations in flow rate, and vessel diameter on wall phenomena in a carotid bifurcation model. MATERIALS AND METHODS: The flow through a model of a carotid artery bifurcation was simulated by means of the finite element method. The whole-blood viscosity is a function of shear rate, and was modeled by the Carreau-Yasuda (CY) model. Flow rate and vessel morphology were assessed with magnetic resonance imaging. Flow rate, blood viscosity, and hematocrit levels (Hct) were measured in 49 healthy volunteers. We propose an adaptation of the CY model so that differences in Hct can be incorporated; furthermore, plasma viscosity was varied in the CY model. RESULTS: The data from our model indicate that flow increases have a larger effect on the WSS than predicted with a simple paraboloid model. Hct had more influence on the WSS when the plasma viscosity was low. Low plasma viscosity was associated with a low WSS, which implies a contradiction, because both high WSS and low plasma viscosity are thought to be indicators for a healthy system. Maximum WSS oscillations were found at the edges of the recirculation region. CONCLUSIONS: Flow and diameter changes have significant influence on wall shear stress values; the same is true for the viscosity, but to a lesser extent.

Adult↗

A new approach to contour detection in x-ray arteriograms: the wavecontour.

OBJECTIVES: We sought to develop a novel approach (the Wavecontour) for the detection of contours in vascular x-ray images, designed to eliminate any systematic underestimation or overestimation for vessel sizes in the range of 0.5 to 15 mm and further minimize the influence of the user-defined start points and end points. MATERIALS AND METHODS: This method is based on the Wavefront Propagation principle in a 2-stage approach. Two validation experiments were performed: a Plexiglas phantom study (tube sizes ranging from 0.51 to 9.9 mm) and an in vivo patient study (114 patients with various degrees of stenosis). RESULTS: The phantom study demonstrated an accuracy of 0.007 mm and a precision of 0.072 mm. The patient study showed a high similarity between the detected and the expert-drawn contours: 93% for a threshold of 1.0 pixel and 81% for a threshold of 0.5 pixels. Furthermore, the contours are robust in complex lesions and are almost independent in the middle part of the segment from the user-defined start point and end point. A variation of only 0.6 pixels exists in the middle 60% of the contours. CONCLUSIONS: Our new Wavecontour approach performs very well on phantom images as well as on clinical data over the whole range of 0.5 to 15 mm and results in more robust QCA/QVA analyses.

Algorithms↗

Variability in densitometric assessment of pulmonary emphysema with computed tomography.

OBJECTIVES: The objectives of this study were to investigate whether computed tomography (CT) densitometry can be applied consistently in different centers; and to evaluate the reproducibility of densitometric quantification of emphysema by assessment of different sources of variation, ie, intersite, interscan and inter- and intraobserver variability, in comparison with intersubject variability. MATERIALS AND METHODS: In 5 different hospitals, 119 patients with emphysema were scanned using standardized protocols. In each site, an observer performed a quantitative densitometric analysis (including blood recalibration) on the corresponding patient group (n=23-25) and one observer analyzed the entire group of 119 patients. After several months, the latter observer analyzed all data for a second time. Subsequently, different sources of variation were assessed by variance component analysis with and without volume correction of the data. RESULTS: Inter- and intraobserver variability marginally contributes to the total variability (<0.001%). The interscan variability was 0.02% of the total variation after application of volume correction. The intersite variability was 48% as a result of one deviating CT scanner. Air recalibration normalized deviating air densities in CT scanners. Within sites, the intersubject variability ranged between 93% and 99% based on the analysis of 2 subsequent CT scans of the patients. CONCLUSIONS: Almost all variability in the density measurement of emphysema originates from differences between scanners and from differences in severity of emphysema between patients. Lung densitometry with multislice CT scanners is a highly reproducible measurement, especially if corrected for lung volume, because this reduces interscan variability.

Absorptiometry, Photon↗

Accurate quantitation of regurgitant volume with MRI in patients selected for mitral valve repair.

OBJECTIVE: Echocardiography, the currently preferred diagnostic approach for mitral valve regurgitation, cannot accurately quantify the amount of regurgitation. Flow quantification with MRI is possible, but the conventional method (1-directional velocity-encoding) acquires the flow at a fixed location during the cardiac cycle, which is not necessarily the location of the mitral valve during the whole cycle. In this study, the exact flow through the mitral valve was quantified with a 3-directional velocity-encoded MRI approach. METHODS: Ten patients with severe mitral valve regurgitation (class 3-4+with echocardiography) resulting from systolic restrictive motion of both leaflets (Carpentier IIIb) which were selected for valve repair and 10 healthy volunteers without cardiac valvular disease confirmed with echocardiography were included in this study. The intra-ventricular flow was sampled with a radial stack of six acquisition planes parallel to the long-axis of the left ventricle. Three-directional velocity-encoded MRI was performed resulting in the intra-ventricular flow velocity vector field for 30 phases during the cardiac cycle. The position of the mitral valvular plane in this vector field was indicated manually for each phase. Velocity values perpendicular to this plane determined the flow through the mitral valve. Both the 3-directional encoded mitral valve flow and the 1-directional encoded mitral valve flow were compared with the flow determined with MRI at the ascending aorta. RESULTS: One-directional velocity-encoded MRI showed a mean overestimation (P<0.01) of 25 ml/cycle compared to the aortic flow. Correlation was very poor (r(P)=0.15, P=0.68). The 3-directional velocity-encoded MRI on the other hand, showed no over/underestimation and a good correlation (r(P)=0.91, P<0.01 for volunteers, r(P)=0.90, P<0.01 for patients). The regurgitant flow fractions were between 3 and 30%. CONCLUSION: With 3-directional velocity-encoded MRI, measurement of the flow through the mitral valve is accurate and reproducible. This is a valuable tool for diagnosing and absolute quantification of regurgitant volume.

Adult↗

Randomized, controlled trial of secondary prevention of coronary sclerosis in normocholesterolemic patients using pravastatin: final 5-year angiographic follow-up of the Prevention of Coronary Sclerosis (PCS) study.

BACKGROUND: The potential benefit of cholesterol-lowering therapy for normocholesterolemic patients with coronary artery disease (CAD) has not been clarified. The Prevention of Coronary Sclerosis (PCS) Study was designed to evaluate the effect of pravastatin on secondary prevention of progression of CAD in normocholesterolemic patients for a period of 5 years. METHODS: A total of 329 patients with CAD were enrolled. Normocholesterolemic patients were defined by a serum total cholesterol (TC) level of 180-219 mg/dl. Patients in this group were randomized into pravastatin and dietary control groups. Patients whose serum TC level fell outside the normal range were divided into a high-cholesterol reference group (TC > or = 220 mg/dl) and a low-cholesterol reference group (TC < 180 mg/dl). Patients in the pravastatin and high-cholesterol groups received pravastatin 10 mg/day. Coronary angiography was performed at baseline, 2 years, and 5 years and analyzed by quantitative coronary arteriography. Angiographic coronary progression was evaluated by minimum obstruction diameter (MOD) and mean segment diameter (MSD). RESULTS: At 5 years, change in MOD was significantly (change, P=0.033; change/years, P=0.032) less in the pravastatin group (-0.04 +/- 0.17 mm) than in the dietary control group (-0.16 +/- 0.27 mm). Although a similar trend was observed in the MSD results, the differences were not significant. CONCLUSION: Long-term angiographic data show that cholesterol-lowering therapy by pravastatin prevents progression of coronary atherosclerosis in normocholesterolemic patients with CAD.

Adult↗

Evaluation of a new method for automated detection of left ventricular boundaries in time series of magnetic resonance images using an Active Appearance Motion Model.

The purpose of this study was the evaluation of a computer algorithm for the automated detection of endocardial and epicardial boundaries of the left ventricle in time series of short-axis magnetic resonance images based on an Active Appearance Motion Model (AAMM). In 20 short-axis MR examinations, manual contours were defined in multiple temporal frames (from end-diastole to end-systole) in multiple slices from base to apex. Using a leave-one-out procedure, the image data and contours were used to build 20 different AAMMs giving a statistical description of the ventricular shape, gray value appearance, and cardiac motion patterns in the training set. Automated contour detection was performed by iteratively deforming the AAMM within statistically allowed limits until an optimal match was found between the deformed AAMM and the underlying image data of the left-out subject. Global ventricular function results derived from automatically detected contours were compared with results obtained from manually traced boundaries. The AAMM contour detection method was successful in 17 of 20 studies. The three failures were excluded from further statistical analysis. Automated contour detection resulted in small, but statistically nonsignificant, underestimations of ventricular volumes and mass: differences for end-diastolic volume were 0.3%+/-12.0%, for end-systolic volume 2.0%+/-23.4% and for left ventricular myocardial mass 0.73%+/-14.9% (mean+/-SD). An excellent agreement was observed in the ejection fraction: difference of 0.1%+/-6.7%. In conclusion, the presented fully automated contour detection method provides assessment of quantitative global function that is comparable to manual analysis.

Adolescent↗

Accurate and reproducible mitral valvular blood flow measurement with three-directional velocity-encoded magnetic resonance imaging.

A new method for quantifying the transvalvular flow through the mitral valve (MV) based on three-directional velocity-encoded magnetic resonance imaging (MRI) is presented. For thirty time phases during one cardiac cycle, the three-dimensional (3D) velocity vector field of the blood flow is reconstructed from the MRI measurement. Retrospectively, for each time phase, the MV-plane is indicated manually in the velocity data and the flow through this plane is determined, representing the MV flow. Measurements are performed in 10 healthy volunteers. The new method is compared to the conventional, one-directional velocity-encoded MRI method for which an acquisition plane is positioned at the mitral valve at end-systole and remains fixed during the acquisition. The flow measurements with the new method correlate very well with the flow measured in the aorta (r(p)=0.92, p<0.01), whereas the conventional method shows no statistically significant correlation (r(p)=0.15, p=0.68). The low differences between the flow measured at the MV and the flow in the aorta proves high accuracy of the new method. Also, the new method shows very low intra- and interobserver variation, proving the high reproducibility. Three-directional velocity-encoded MRI is a patient-friendly and easy-to-use method suitable for quantifying accurately and reproducibly the transvalvular MV flow.

Adult↗

Automated short-axis cardiac magnetic resonance image acquisitions: accuracy of left ventricular dimension measurements in normal subjects and patients.

RATIONALE AND OBJECTIVE: This study investigates the use of an automated observer-independent planning system for short-axis cardiovascular magnetic resonance (MR) acquisitions in the clinical environment. The capacity of the automated method to produce accurate measurements of left ventricular dimensions and function was quantitatively assessed in normal subjects and patients. METHODS: Fourteen healthy volunteers and 8 patients underwent cardiovascular MR (CMR) acquisitions for ventricular function assessment. Short-axis datasets of the left ventricle (LV) were acquired in 2 ways: manually planned and generated in an automatic fashion. End-diastolic volume (EDV), end-systolic volume (ESV), ejection fraction (EF), and left ventricular mass (LVM) were derived from the 2 datasets. The agreement between the manual and automatic planning methods was assessed. RESULTS: The mean differences between the manual and automated CMR planning methods for the normal subjects and patients were 5.89 mL and 1.93 mL (EDV), 1.14 mL and -0.41 mL (ESV), 0.81% and 0.89% (EF), and 4.35 g and 3.88 g (LVM), respectively. There was no significant difference in ESV and EF. LVM significantly differed in both groups, whereas EDV was significantly different in the normal subjects and insignificantly different in the patients. The variability coefficients were 2.8 and 3.59 (EDV), 3.3 and 5.03 (ESV), 1.79 and 2.65 (EF), and 4.36 and 2.27 (LVM) for the normal subjects and patients, respectively. The mean angular deviation of the LV axes turned out to be 8.58 +/- 5.76 degrees for the normal subjects and 8.35 +/- 5.15 degrees for the patients. CONCLUSIONS: Automated CMR planning method can provide accurate measurements of LV dimensions in normal subjects and patients, and therefore, can be used in the clinical environment for functional assessment of the human cardiovascular system.

Adult↗

Comparison of the sensitivities of 5 different computed tomography scanners for the assessment of the progression of pulmonary emphysema: a phantom study.

RATIONALE AND OBJECTIVES: To compare the sensitivities of 5 different computed tomography scanners (4 multislice CT [MSCT] and 1 single-slice CT) in the assessment of the progression of pulmonary emphysema. METHODS: A Perspex cylinder phantom was constructed containing small pieces of polythene foam with densities representative of lung. Changing the cylinder's volume simulated subtle lung density changes. The sensitivity to density changes was defined by the variation in the residual errors from the linear regression line between time and density. RESULTS: The single-slice CT scanner was significantly less sensitive to density changes than MSCT scanners. Also, among MSCT scanners, small but significant differences were found when the standardized acquisition protocol was used. CONCLUSIONS: Considering the large sensitivity differences between single- and multislice CT scanners, we would recommended using MSCT scanners in clinical multicenter trials in emphysema. The protocol standardization of MSCT scanners can still be further improved.

Humans↗

Quantitative assessment of the morphology of renal arteries from X-ray images: quantitative vascular analysis.

RATIONALE AND OBJECTIVES: With the advent of interventional vascular procedures, objective and reproducible tools are needed to assist clinical decision-making and to assess intervention efficacy. The success of quantitative coronary arteriography (QVA) in objectively assessing cardiovascular morphology has initiated the software development for quantitative analysis of peripheral vasculature. The objective of this study was to evaluate the applicability and quality of a new QVA package applied to renal arteries. METHODS: A calibration method was developed using markers mounted on a catheter's shaft, ensuring accurate calibration even with small catheter sizes. Given the high prevalence of ostial stenoses in peripheral vessels, a dedicated vessel analysis method was developed to assess these stenoses. Its reproducibility was determined in renal angiography. Variance component analysis was performed to evaluate sources of variability, using angiograms from 74 patients suspected of renovascular hypertension. RESULTS: For intraobserver variability, the 95% confidence intervals of differences in percent diameter stenosis and minimal lumen diameter were -1.99%-1.04% (P = 0.53, n = 48) and -0.081 mm-0.023 mm (P = 0.27, n = 48), respectively. For the interobserver variability, intervals were -1.86%-2.80% (P = 0.69, n = 66) and -0.46 mm-0.053 mm (P = 0.12, n = 46), respectively. CONCLUSIONS: The contribution of intraobserver variation was negligible. The contribution of interobserver variation for different parameters was negligible or comparable with the variation caused by image acquisition. These conclusions demonstrate that QVA can reproducibly measure renal artery geometry.

Calibration↗

Validation of a new method for the detection of pathlines in vascular x-ray images.

This article presents the validation of a new pathline approach, based on the wavefront propagation principle, on a large variety of vascular images. The purpose of the novel approach, called wavepath, was to minimize the variability of the measurements in the quantitative vascular analysis by reducing the variability that is introduced by manually placing the start and end points of the vessel segment. This results in a robust and reproducible pathline detection that is subsequently used in the analysis and lesion quantification. The validation study that was performed concerned a large variety of vessel segments and showed that the approach results in a pathline that is totally constant in its middle part. This holds not only for the straight segment version but also for the bifurcation version and ostial version of the algorithm. Moreover, the average number of additional points per pathline needed to guide the wavepath through the correct vessel is minimized to 0 for the straight segments, 0.06 for aortic bifurcations, 0.25 for carotid bifurcations, and 0.08 for the ostial segments. In conclusion, our new approach performs very well in all types of vascular x-ray images, resulting in a stable and robust pathline detection.

Angiography↗

End-diastolic and end-systolic volume from the left ventricular angiogram: how accurate is visual frame selection? Comparison between visual and semi-automated comnputer-assisted analysis.

BACKGROUND: End-diastolic (ED), end-systolic (ES) left ventricular (LV) volumes and LV ejection fraction (LVEF) are important parameters for clinical decision making in heart disease. In clinical practice the frames from cine-angiography with the largest and smallest opacified LV areas are visually selected and the endocardial borders traced as LVED and LVES contours, respectively. We compared the accuracy of this visual method using two frames with a semi-automated computer assisted frame-by-frame analysis of the complete opacified cardiac cycles. METHODS AND RESULTS: In 17 patients a biplane LV cine-angiogram was obtained at 25 frames/s. Complete frame-by-frame analysis was performed using semi-automatic border detection software. Experienced independent observers visually selected and manually traced LVED and LVES in the so-called visually assessed two-frame method in a consensus meeting. LV volumes were calculated by the area-length method. Mean LVEDV, LVESV and LVEF were 133 +/- 57, 56 +/- 40 ml and 61 +/- 16%, respectively, for the visually assessed two-frame method, and 117 +/- 49, 53 +/- 33 ml and 60 +/- 13%, respectively, for the semi-automated computer assisted frame-by-frame method. LVEDV was significantly higher in the visually assessed two-frame method (p < 0.01). Linear regression analysis showed an excellent correlation between semi-automated computer-assisted frame-by-frame and the visually assessed two-frame LVEDV (y = 1.2x - 2.9; r2 = 0.98), LVESV (y = 1.2x - 8.2; r2 = 0.97) and good linear correlation for LVEF (p = 1.2x - 3.6; r2 = 0.82). Bland-Altman analysis showed respectively a bias of 16.4, 2.4 ml and 5.0% with overall wide limits of agreement (-6.6 and 39.4 ml; -16.6 and 21.4 ml; -9.0% and 19.1%). CONCLUSION: Correlation is excellent when visually assessed LVED and LVES are compared with a semi-automated computer assisted frame-by-frame analysis. However, the visually assessed two-frame method tends to overestimate the volumes obtained by semi-automated computer-assisted frame-by-frame analysis, especially for LVEDV, indicating that visual selection will yield a higher LVEF, which may influence clinical decision making.

Angiocardiography↗

Low restenosis rate of the NIR coronary stent: results of the Danish multicenter stent study (DANSTENT)--a randomized trial comparing a first-generation stent with a second-generation stent.

BACKGROUND: Larger studies evaluating the angiographic results of second-generation stents are scarce. The objectives of this study were to assess current standards of angiographic and clinical outcomes after implantation of the second-generation stainless steel stent, NIR (Medinol Ltd, Tel Aviv, Israel), and to compare the outcomes with those of the first-generation Palmaz-Schatz (PS) stent (Johnson & Johnson, Warren, NJ). METHODS: Patients having coronary artery lesions that could be covered by a stent of 15 mm in length were randomly assigned to receive the NIR or the PS. Procedural success, 6-month angiographic findings, and 1-year clinical outcomes were determined. RESULTS: In 424 patients included in the study, the overall procedural success rate was high (NIR 98%, PS 99%, P =.90). Follow-up angiography was conducted in 91% of the patients. The overall rate of angiographic restenosis was low in both groups (NIR 9.9%, PS 12.6%, P =.35). We found a low restenosis rate in vessels with a minimal lumen diameter >3.1 mm after the procedure, particularly in the NIR group (<6%). The rate of target lesion revascularization after 1 year did not differ (NIR 12%, PS 10%, P =.47). CONCLUSIONS: The angiographic and clinical outcomes after implantation of the second-generation stainless steel stent were not significantly better than those of the first-generation stent. The low restenosis rates, particularly in patients with the largest minimal lumen diameters after stent implantation, warrants circumspection when planning the evaluation of newer stent technologies that aim to further reduce coronary restenosis.

Angina Pectoris↗

Automatic model-based contour detection and blood flow quantification in small vessels with velocity encoded magnetic resonance imaging.

RATIONALE AND OBJECTIVES: The quantitative assessment of blood flow in peripheral vessels from phase-contrast magnetic resonance imaging studies requires the accurate delineation of vessel contours in cross-sectional magnetic resonance images. The conventional manual segmentation approach is tedious, time-consuming, and leads to significant inter- and intraobserver variabilities. The aim of this study was to verify whether automatic model-based segmentation decreases these problems by fitting a model to the actual blood velocity profile. METHODS: In this study 2 new fully automatic methods (a static and a dynamic approach) were developed and compared with manual analyzes using phantom and in vivo studies of internal carotid and vertebral arteries in healthy volunteers. The automatic segmentation approaches were based on fitting a 3D parabolic velocity model to the actual velocity profiles. In the static method, the velocity profiles were averaged over the complete cardiac cycle, whereas the dynamic method takes into account the velocity data of each cardiac time bin individually. Materials consisted of the magnetic resonance imaging data from 3 straight phantom tubes and the blood velocity profiles of 8 volunteers. RESULTS: For the phantom studies, the automatic dynamic approach performed significantly better than the manual analysis (intraclass correlations [ICC] of 0.62-0.98 and 0.30-0.86, respectively). For the assessment of the total cerebral blood flow in the in vivo studies, the automatic static method performed significantly better than the manual 1 (ICC of 0.98-0.98 and 0.93-0.95, respectively). However, the automatic dynamic method was not significantly better than the manual 1 (ICC = 0.92-0.96) but had the advantage of providing additional parameters. CONCLUSION: Blood flow in magnetic resonance images of small vessels can be assessed accurately, rapidly, and fully automatically using model-based postprocessing by fitting a first approximation of the velocity profile to the actual flow data.

Adult↗

One core laboratory at two international sites, is that feasible? An inter-core laboratory and intra-observer variability study.

To assess the magnitude of differences in QCA outcomes between two cooperating core laboratories in a single trial, we have carried out an inter-core laboratory variability study. Two QCA experts at the Montreal Heart Institute and Heart Core Leiden both analyzed 32 lesions (pre- and post-intervention) in accordance with previously agreed upon standard operating procedures. One of the experts analyzed the whole image set twice to determine the intraobserver variability. The inter-core laboratory differences in the acute gain (n = 31 pairs) are non-significant. The systematic errors of the individual measurements (n = 63 analyses) show an excellent intraclass correlation coefficient of reliability (>75%), except for the stent length (67.7%). The corresponding random errors are small. In general, the intra-observer systematic and random errors are both slightly smaller than those for the inter-core laboratory study. QCA analyses in clinical trials can be carried out in core laboratories at two different locations if and only if highly standardized conditions are maintained.

Angioplasty, Balloon, Coronary↗

Reproducibility of total cerebral blood flow measurements using phase contrast magnetic resonance imaging.

PURPOSE: To evaluate reproducibility of total cerebral blood flow (CBF) measurements with phase contrast magnetic resonance imaging (pcMRI). MATERIALS AND METHODS: We repeated total CBF measurements in 15 healthy volunteers with and without cardiac triggering, and with and without repositioning. In eight volunteers measurements were performed at two different occasions. In addition, measurement of flow in a phantom was performed to validate MR measurements. RESULTS: A difference of 40.4 ml/minute was found between CBF measurements performed with and without triggering (P < 0.05). For repeated triggered measurements, the coefficient of variation (CV) was 7.1%, and for nontriggered measurements 10.3%. For repeated measurements with repositioning, the CV was 7.1% with and 11.2% without triggering. Repeated measurements at different occasions showed a CV of 8.8%. Comparing measured with real flow in the phantom, the triggered differed 4.9% and the nontriggered 8.3%. CONCLUSION: The findings of this study demonstrate that pcMRI is a reliable method to measure total CBF in terms of both accuracy and reproducibility.

Adult↗