PubMed Health⌕ Search

Biomedical subjects

Johan Ingri

Publications and source records attributed to Johan Ingri.

3 recordsLinked to original sources

Trace metal speciation in brackish water using diffusive gradients in thin films and ultrafiltration: comparison of techniques.

Diffusive gradients in thin films (DGT) and ultrafiltration were used to measure trace metal concentrations in the Baltic Sea. The results provide the first comparison of these two fundamentally different speciation methods for trace metals. Cd, Cu, Mn, Ni, and Zn were measured at two sites with different total trace metal concentrations. DGT units prepared with APA-gel as diffusive layer and Chelex 100 resin as binding agent were used throughout the study. The ultrafiltration was performed with Millipore Prep/Scale modules with cutoffs of 1 and 10 kDa. Concentration levels of Mn, Zn, and Cd measured by DGT agreed with the concentrations measured in 1 kDa ultrafiltered samples. For Cu and Ni the ultrafiltered concentrations exceeded the DGT-labile concentrations. The ability of DGT to preconcentrate metals was found to be an analytical advantage compared with ultrafiltration. DGT appears to be a good alternative to 1 kDa ultrafiltration for measurement of truly dissolved Mn, Cd, and Zn in the Baltic Sea.

Diffusion↗

Evaluation and optimization of two complementary cross-flow ultrafiltration systems toward isolation of coastal surface water colloids.

While colloidal phases in natural waters are important to the speciation and bioavailability of trace metals and organic compounds, accurate isolation of these submicron entities from their lower molecular-weight counterparts has proved challenging. Here, both laboratory and field experiments have been conducted to constrain integrity aspects of two different cross-flow filtration (CFF) systems. We tested both a commonly applied 5000 cm2 CFF system (Pellicon2, Millipore; manufacturer-specified 1 and 3 kDa cutoff) and a less studied mini-CFF system with a 50 cm2 membrane area (Pellicon Lab Scale XL, Millipore; with 5, 10, 100, and 1000 kDa cutoff). A natural water matrix amended with a series of fluorescently tagged colloidal probes was employed to demonstrate that a cross-flow ratio (CFR; retentate-to-permeate flux) > 15 was required for both of these systems to obtain high recoveries of colloids. Contrary to previous calibrations of CFF, also at colloid concentrations characteristic of natural waters, the established retention profiles for the colloid probes on these systems, when operated under CFR > 15, affirmed the manufacturer-specified cutoff values (in parentheses): 2.4 kDa (1 kDa), 3.3 kDa (3 kDa), 6.1 kDa (5 kDa) and 8.7 kD (10 kDa). A concentration factor (cf) > 10 was found necessary for the reliable determination of the colloidal pool of several elements in the surface waters of the open Baltic Sea. Application of CFR > 15 and cf > 10 returned recoveries around 100% for the studied organic carbon, Ca, Mo, Fe, Cu, and Ni on both systems. Furthermore, the trend of colloid association for the transition elements in the offshore Baltic surface waters followed expectations from their Irving-Williams series of coordination chemistry.

Biological Availability↗

Multielemental analysis of Mn-Fe nodules by ICP-MS: optimisation of analytical method.

Two acid digestion procedures (microwave-assisted and room temperature) were developed for the quantitative analysis of ferromanganese nodules by inductively coupled plasma double focusing sector field mass spectrometry (ICP-SFMS). Different compositions of the acid mixture, dilution factors and corrections for spectral interferences were tested. A combination of nitric, hydrochloric and hydrofluoric acids is necessary for complete sample digestion, with lowest acid to sample ratios (v/m) of 15 and 1.5, respectively, for the last two acids. Sample dilution factors higher than 2 x 10(4) should be used in order to decrease matrix effects and provide robust long-term instrumental operation. In spite of high dilution, method detection limits in the sub-microg g(-1) range were obtained for 54 out of 71 elements tested, due to the high detection capability of ICP-SFMS, as well as the special care taken to ensure the purity of reagents, to clean the instrument sample introduction system and to minimise sample handling. Owing to the presence of unresolved (at the resolution available) spectral interferences, accurate determination of Au, Hg, Os, Pd, Re and Rh is impossible without matrix separation. The accuracy of the entire analytical method was tested by the analysis of two nodule reference materials. The results generated agreed to within +/-2% for about 10, within +/-10% for more than 40 and within +/-20% for about 50 of 53 elements for which certified, recommended or literature values are available. A precision better than 3%, expressed as the between-digestion relative standard deviation (n = 4), was obtained for the majority of elements, except in cases limited by low analyte concentrations.

Journal Article↗