PubMed Health⌕ Search

Biomedical subjects

Johannes Bodner

Publications and source records attributed to Johannes Bodner.

12 recordsLinked to original sources

A comparison of outcomes after robotic open extended thymectomy for myasthenia gravis.

OBJECTIVE: The aim of this study was to analyze the effect of the surgical approach on surgical and neurologic outcomes after extended thymectomy for myasthenia gravis. METHODS: A retrospective analysis of the institutional extended thymectomies for myasthenia gravis within the last decade was performed. Patients of group A (open access by total median sternotomy; n=10; 1996-2002) and of group B (video assisted thoracoscopic surgery approach with the da Vinci robotic system; n=9; 2003-2006) did not differ with regard to gender distribution, age, body mass index, American Association of Anaesthetists score and Osserman classification of myasthenia gravis. Primary endpoints were surgical complications and the symptomatic/neurologic outcome of the extended thymectomy. Secondary endpoints were operating times and hospital stay. RESULTS: Median follow-up was 74+/-23 months in group A and 13+/-10 months in group B. Surgical complications occurred in 4 patients in group A (requiring 2 re-interventions) and in 1 patient in group B (p<0.05). The median dose of Pyridostigminbromid was reduced 3 and 6 months postoperatively in group A to 80% and 60% of the preoperative level and in group B to 66% and 60% of the preoperative level, respectively. Within the first postoperative year all patients of group B had an improvement of their disease whereas 2 patients of group A did not benefit from thymectomy or had a worsening of symptoms. Operating times were significantly shorter in group A (110 (42-152) min vs 154 (94-312) min, p<0.05), hospital stay was significantly shorter in group B (5 (4-15) vs 10 (10-23) days, p<0.05). CONCLUSIONS: The results of this small series favour the robotic approach for extended thymectomy for myasthenia gravis in respect of both surgical and early neurologic outcome. However, prospective randomized trials are required to prove a general validity.

Female↗

The da Vinci robotic system for general surgical applications: a critical interim appraisal.

PRINCIPLES: The recently introduced robotic surgical systems were developed to overcome the limitations of conventional minimally invasive surgery. We analyse the impact of the da Vinci robotic system on general surgery. METHODS: The da Vinci operating robot is a telemanipulation system consisting of a surgical arm cart, a master console and a conventional monitor cart. Since its purchase in June 2001, 128 patients have undergone surgery using the da Vinci robot in our department. The mean age of the 78 female and 50 male patients was 52 (range 18-78) years. RESULTS: The procedures included 29 cholecystectomies, 16 partial fundoplications, 16 extended thymectomies, 14 colonic interventions, 10 splenectomies, 10 bariatric procedures, 7 hernioplasties, 6 oesophageal interventions, 5 adrenalectomies, 5 lower lobectomies, 4 neurinomectomies and 6 others. 122 of 128 procedures (95%) were completed successfully with the da Vinci robot. Open conversion proved necessary in 4 patients due to surgical problems, and two other procedures were completed by conventional laparoscopy due to robot system technical errors. 30-day mortality was 0%, one redo-operation was necessary and two lower complications not requiring surgical re-intervention occurred. The resection margins of all tumour specimens were histologically tumour free. CONCLUSIONS: Various general surgical procedures have proved feasible and safe when performed with the da Vinci robot. The advantage of the system is best seen in tiny areas difficult of access and when dissecting delicate, vulnerable anatomical structures. However, in view of longer operating times, higher costs and the lack of adequate instruments, robotic surgery does not at the moment represent a general alternative to conventional minimally invasive surgery.

Adolescent↗

A critical comparison of robotic versus conventional laparoscopic splenectomies.

The benefit of robotic systems for general surgery is a matter of debate. We compare our initial series of robotic splenectomies with our first series of conventional laparoscopic ones. A retrospective analysis of the first six robotic versus the first six conventional laparoscopic splenectomies is presented. Patients were matched with regard to age, body-mass index, ASA score, and preoperative platelet levels. All procedures were performed by a single surgeon. Size and weight of the resected specimens were comparable in both groups. Median overall operating time was 154 (range, 115-292) min for the robotic and 127 (range, 95-174) min for the laparoscopic group. No complications occurred. There were no open conversions. The median postoperative hospital stay was 7 (robotic group) and 6 (laparoscopic group) days. Median average costs were 6927 dollars for the robotic procedure versus $4084 for the conventional laparoscopic procedure (p < 0.05). Minimally invasive splenectomies are feasible using either conventional laparoscopic techniques or the da Vinci robotic system. In this analysis, procedures performed with the da Vinci robotic system resulted in prolonged overall operative time and significantly higher procedural costs. The use of a robotic system for laparoscopic splenectomy offers, at this stage, no relevant benefit and thus is not justified.

Adult↗

Laparoscopic splenectomy with the da Vinci robot.

BACKGROUND: We report our first series of minimally invasive splenectomies with a robotic surgical system. METHODS: From August 2001 to October 2003, laparoscopic splenectomies with the da Vinci operating robot were performed in 7 patients (five females and two males, ages 20 to 74 years). RESULTS: Indications for splenectomy were hematologic disorders in four patients and hypersplenism in three patients. Median dimensions of the resected spleens were 140 +/- 34 mm x 80 +/- 11 mm x 50 +/- 17 mm and median weight was 307 +/- 193 g. Median total operative time was 147 +/- 58 minutes including 107 +/- 49 minutes for the robotic act. There were no intraoperative complications and no conversions to open surgery. The median postoperative hospital stay was 7 days. CONCLUSION: This first series suggests that robotic splenectomy with the da Vinci surgical system is technically feasible and safe. It provides an alternative to the conventional laparoscopic procedure. Nevertheless, justification for this new technique will require a larger prospective series and longer follow-up.

Adult↗

Robotic resection of an ectopic goiter in the mediastinum.

We report the first robotic resection of an ectopic mediastinal thyroid adenoma in a 72-year-old woman. This intervention was part of staged management for excessive bilateral cervical goiter with intrathoracic dispersion. The robotic resection was found to be feasible and safe. The robotic operating system offers better visual control and operative accuracy than does conventional thoracoscopy.

Adenoma↗

Gallstone ileus: rare and still controversial.

BACKGROUND: Gallstone ileus is a rare disease and accounts for about 1-3% of mechanic ileus of the small bowel, but for 25% of all small bowel obstructions in patients older than 65 years. Concomitant cardiorespiratory diseases or diabetes are frequent in older patients and responsible for the high mortality rate. The aim of the present study was to evaluate and discuss different surgical approaches and to analyze the clinical outcome. METHODS: Four patients with a mean age of 72 years were treated for gallstone ileus at our hospital in the last 10 years. Patients history, operative strategy and their outcome is elucidated and a review of the recent literature is given. RESULTS: In all patients the operative strategy was a one-stage procedure including enterolithotomy, cholecystectomy and closure of the fistula. The 30-day mortality rate was 25%. CONCLUSION: One-stage procedure prevents from cholangitis, cholecystitis and recurrent ileus caused by further gallstones but bears the risk of enteric or biliary leakage after fistula closure. It should therefore be reserved for patients presenting in good general condition with a low degree of cholecystitis.

Aged↗

Long-term follow-up after robotic cholecystectomy.

Most surgeons gain their first clinical experience with surgical robots when performing cholecystectomies. Although this procedure is rather easily applicable for the da Vinci surgical system, the long-term outcome after this operation has not yet been clarified. This study follows up our institutional first series of robotic cholecystectomies (June to November 2001). Patients were assessed on the basis of standardized management including a quality-of-life questionnaire, clinical examination, blood tests, and abdominal sonogram. The follow-up rate for 23 patients after robotic cholecystectomy was 100 per cent and the median follow-up time 33 (30-35) months. There was one (4%) recurrence of gallstone disease in a patient who suffered from solitary choledocholithiasis 29 months after robotic cholecystectomy. Abdominal sonogram, clinical examinations, and blood tests revealed no post-cholecystectomy-specific pathological findings. The main long-term symptoms were bloating (57%), heartburn (43%) and nausea (30%). Of the patients, 96 per cent (22 patients) felt that the operation had cured or significantly improved their specific preoperative symptoms. Long-term results after robotic laparoscopic cholecystectomy are excellent and comparable to those for the conventional laparoscopic procedure. The advanced vision control and instrument maneuverability of robotic surgery might open minimally invasive surgery also for complicated gallstone disease and bile duct surgery.

Adult↗

Early experience with robot-assisted surgery for mediastinal masses.

BACKGROUND: We report the experience of a single institution with the minimally invasive resection of mediastinal masses using the da Vinci robotic surgical system. METHODS: From August 2001 to June 2003, 14 patients (5 men and 9 women aged from 21 to 77 years) with mediastinal masses were operated on minimally invasively with the da Vinci robotic system. This consisted of 9 thymectomies (6 thymomas, 2 nonatrophic thymic glands, 1 thymic cyst), 3 resections of paravertebral neurinomas, 1 ectopic mediastinal parathyroidectomy, and 1 resection of a lymphangioma. RESULTS: Complete, extended thymectomy was accomplished in all 9 cases, proven by examination of the thymic bed and resected specimen. In 1 patient with an hourglass-shaped neurinoma, conversion to an open procedure was necessary because the excessive size of the tumor limited vision. The median overall operation time was 166 minutes (range, 61 to 182) including 110 minutes (range, 46 to 142) for the robotic act. There were no intraoperative complications or surgical mortality. CONCLUSIONS: These preliminary results of our series suggest that application of the da Vinci robotic surgical system for resection of selected mediastinal masses is technically feasible and safe. It provides an alternative to open approaches and "conventional" thoracoscopy. Nevertheless, this new technique requires further investigation in larger series and longer follow-up.

Adult↗

Congenital cystic lung disease: diagnostic and therapeutic considerations.

Congenital lung cysts such as congenital cystic adenomatoid malformation, pulmonary sequestration, congenital lobar emphysema, and bronchogenic cysts are rare but fascinating anomalies of lung development. While there are many similarities in terms of their presenting features, there are particular differences between the diagnostic groups that are important to highlight, especially in relationship to approaches to imaging and long-term outcome. A case of each entity is presented with an emphasis on the contemporary approach to diagnostic investigations and therapeutic options.

Adult↗

Comparison of automated cellular imaging system and manual microscopy for immunohistochemically stained cryostat sections of lung cancer specimens applying p53, ki-67 and p120.

Seventy-one frozen lung tissue specimens from 52 patients suffering from non-small cell lung cancer (NSCLC) were analysed in this study. Cryostat sections were stained with monoclonal antibodies against p53, ki-67 and p120, all of which are of prognostic value in NSCLC. Slides were evaluated by standard manual microscopy (MM) and using a new Automated Cellular Imaging System (ACIS). The results obtained with ACIS correlated significantly with MM examination (p<0.001). However, ACIS showed a higher sensitivity, especially for specimens with a low infiltration volume. In 15 (6.8%) MM negative cases singular positive cells were identified with ACIS. In cases with a high infiltration volume subjective (MM) quantitation tended to overestimate the number of infiltrating cells. ACIS guaranteed a high reproducibility of data. We conclude that ACIS-assisted analysis is a valid means of investigating the p53, ki-67 and p120 antibody expression in cryostat sections of lung cancer specimens. ACIS can complement conventional manual microscopy due to its higher accuracy, sensitivity and better reproducibility of data.

Adenocarcinoma↗