The effect of dose reduction and feasibility of edge-preserving noise reduction on the detection of liver lesions using MSCT.

The purpose of this study was to assess the effect of dose reduction and the potential of noise reduction filters on image quality and the detection of liver lesions using MSCT. Twenty-nine patients with a total of 40 liver lesions underwent 16-slice CT (120 kV; 180 mAs). Virtual noise was added to CT raw datasets simulating effective mAs levels of 155, 130, 105, 80, 55, 30 and 10 mAs. All datasets were post-processed with an edge-preserving noise-reduction filter (ANR-3D), yielding a total of 15 datasets per patient. Ten radiologists performed independent evaluations of image quality, the presence of liver lesions and diagnostic confidence. Quantitative noise and contrast-to-noise ratios (CNR) were obtained. Superior image quality (P < 0.02), reduction of image noise (P < 0.001) and the increase of lesion-to-liver CNR (P < 0.001) were observed in images processed with the ANR-3D filter. Sensitivity for lesion detection remained unchanged down to 105 mAs (CTDI(w) 6.6 mGy) without filter and 80 mAs (CTDI(w) 5.1 mGy) with ANR-3D. Confidence was rated significantly higher for datasets reconstructed with ANR-3D. The use of a noise-reducing, but edge-preserving filter (ANR-3D) is a promising option to reduce further the radiation dose in liver CT.

Adult↗

Detection of colorectal polyps: comparison of multi-detector row CT and MR colonography in a colon phantom.

PURPOSE: To compare multi-detector row (four- and 16-section) computed tomography (CT), including a low-dose protocol, with high-field-strength (1.5- and 3.0-T) magnetic resonance (MR) imaging for reader detection of colorectal polyps in a colon phantom. MATERIALS AND METHODS: A colon phantom with simulated haustral folds and 10 polyps of varying size (2.0-8.0 mm) was imaged at four- and 16-section CT (section thicknesses of 1.25 and 0.75 mm, reconstruction increments of 0.8 and 0.7 mm, and 100 and 10 mAs, respectively, and 120 kV for both) and at 1.5- and 3.0-T MR imaging (three-dimensional gradient-recalled echo sequence, section thickness of 1.4 mm). Three-dimensional endoluminal images were assessed by 10 reviewers for each modality regarding polyp detection. Comparisons of sensitivities were performed by using logistic regression. RESULTS: Overall, polyps were detected with a sensitivity of 87% (95% confidence interval [CI]: 80%, 94%) at four-section CT, 92% (95% CI: 87%, 97%) at 16-section CT, 56% (95% CI: 46%, 66%) at 1.5-T MR imaging, and 55% (95% CI: 45%, 65%) at 3.0-T MR imaging. The detection of polyps at least 4 mm in diameter was not influenced by the modality or radiation dose (sensitivity of 100%). CT performed in low-dose mode depicted all polyps with a diameter of at least 3 mm. Polyps smaller than 3 mm in diameter were detected with a sensitivity of 7.5% (1.5-T MR imaging), 22.5% (3.0-T MR imaging), and 20% (low-dose CT); detection rates were significantly greater (P < .001) with normal-dose CT (four section, 67.5%; 16 section, 82.5%). Increased spatial resolution (with CT) and higher field strength (with MR imaging) had no significant effect on polyp detection. CONCLUSION: With both multi-detector row CT and MR imaging, readers detected polyps above the clinically relevant threshold diameter of 6 mm, with similar sensitivities.

Colonic Polyps↗

Further evidence of a close anatomical relation between the oesophagus and pulmonary veins.

BACKGROUND: Atrio-oesophageal fistula has been reported as a rare but life-threatening complication of ablation of atrial fibrillation (AF). Therefore, the position of the oesophagus in relation to the left atrium (LA) is of major importance for AF ablation. METHODS AND RESULTS: In order to investigate the possible anatomical variability between the oesophagus and the left atrium, multidetector-row spiral computed tomography (MDCT) of 60 healthy males (age 58.1+/-5.1 years; LA diameter 5.4+/-0.7 x 3.8+/-0.6 cm; LA volume 60.5+/-15.4 ml) was analyzed. The distance between the oesophagus and the ostia of the pulmonary veins (PV) ranged between 0 and 50.7 mm. Especially for the left PV, the oesophagus was closer than 5 mm to the ostia in 29 cases (48%; n = 24 for left superior PV; n = 10 for left inferior PV; n = 0 for right superior PV; n = 1 for right inferior PV). In addition, the oesophagus was very close to the LA wall (0.8+/-0.9 mm; range 0-3.3 mm). Intraobserver variability was 1.1+/-0.7 mm or 3.5%. CONCLUSION: The position of the oesophagus in relation to the LA and the PV demonstrates high variability. In many cases, the oesophagus is very close to the ostia of the PVs and lies only a short distance from the LA wall. Thus, an anatomical localization of the oesophagus may be critical before or during AF ablation to prevent atrio-oesophageal fistula, especially as there is a need for transmural atrial lesions.

Adult↗

Virtual colonography: identification and differentiation of colorectal lesions using multi-detector computed tomography.

OBJECTIVE: Early detection of precancerous or malignant lesions may be decisive for prognosis of patients with colorectal cancer. In this prospective feasibility study, multi-detector spiral computed tomography (CT) colonography was compared with conventional colonoscopy for the detection of colorectal polyps. MATERIAL AND METHODS: Seventy-eight patients underwent CT colonography (standard colonoscopy preparation, distension with room air, prone and supine position) immediately before colonoscopy. Sixty-five (83%) were asymptomatic screening subjects, while the rest had symptoms suggestive of colorectal disease. Presence, location, and size of lesions were prospectively assessed. Sensitivity, specificity, and positive and negative predictive values of CT colonography were calculated using conventional colonoscopy as the reference standard. RESULTS: Conventional colonoscopy was normal in 52 patients. In 26 patients a total of 49 polyps and 3 carcinomas were identified. All three carcinomas and 39 polyps (80%) were identified by CT colonography. Seven of 7 polyps > or = 10 mm (100%), 13 of 16 polyps of 6 to 9 mm (81%), and 19 of 26 polyps < or = 5 mm (73%) in diameter were identified. Fourteen false-positive findings (10 of which were < or = 5 mm in diameter) were related to 8 patients (specificity at the patient level was 86%). In 10 patients, a total of 10 polyps were missed by CT colonography, 7 of which were < or = 5 mm in diameter. CONCLUSIONS: In this feasibility study, multi-detector spiral CT colonography allows accurate detection of polyps > 5 mm in diameter, but at the expense of low specificity in the small size range.

Colonic Polyps↗

Endoscopic retrograde cholangiopancreatography, intraductal ultrasonography, and magnetic resonance cholangiopancreatography in bile duct strictures: a prospective comparison of imaging diagnostics with histopathological correlation.

OBJECTIVES: A variety of imaging techniques are available to diagnose bile duct strictures; the most effective imaging technique, however, has not been established yet. In the present study, we compared the impact of endoscopic retrograde cholangiopancreatography (ERCP), intraductal ultrasonography (IDUS), and magnetic resonance cholangiopancreatography (MRCP) with regard to diagnosing bile duct strictures. METHODS: We prospectively examined 33 patients with jaundice due to bile duct strictures by ERCP plus IDUS and MRCP. The objectives were to assess diagnostic quality of imaging, complete presentation of the bile duct, and differentiation of malignant from benign lesions. Surgical and histopathological correlations, which were used as the gold standard, were available in all cases since all included patients underwent laparotomy. RESULTS: Diagnostic image quality for ERCP was 88% and 76% for MRCP (p > 0.05). Comparing ERCP and MRCP, complete presentation of the biliary tract was achieved in 94% and 82%, respectively (p > 0.05). ERCP and MRCP allowed correct differentiation of malignant from benign lesions in 76% and 58% (p= 0.057), respectively. By supplementing ERCP with IDUS, the accuracy of correct differentiation of malignant from benign lesions increased significantly to 88% (p= 0.0047). CONCLUSIONS: Comparing ERCP with MRCP, we found adequate presentation of bile duct strictures in high imaging quality for both techniques. ERCP supplemented by IDUS gives more reliable and precise information about differentiation of malignant and benign lesions than MRCP alone without additional imaging sequences.

Analysis of Variance↗

CT colonography: Protocol optimization with multi-detector row CT--study in an anthropomorphic colon phantom.

PURPOSE: To determine optimal detector collimation, section thickness, and tube current for multi-detector row computed tomography (CT) colonography. MATERIALS AND METHODS: An anthropomorphic colon phantom with simulated polyps of varying size (2, 6, 8, 10, and 12 mm) was examined by using multi-detector row CT with varying combinations of detector collimation (4 x 1.0 mm and 4 x 2.5 mm), dose per section (10, 20, 40, 60, 80, 100, and 140 mAs), and section thickness/reconstruction interval (1.25/0.6, 2.0/1.0, 3.0/1.0, and 5.0/2.0 mm). Polyp depiction, longitudinal polyp distortion, and presence of rippling artifacts were assessed on reformatted three-dimensional endoluminal images by three reviewers. RESULTS: Longitudinal distortion and rippling artifacts increased with increasing section thickness and use of broader detector collimation. Polyps 8 mm or larger were depicted with any combination of section thickness, detector collimation, and tube current. Depiction of polyps 6 mm or smaller depended on the detector collimation/reconstructed section thickness and was rated optimal for the 4 x 1.0-mm detector collimation with a section thickness of 1.25 mm. This was also observed for low-dose protocols. Polyps 6 mm or smaller that were not detected with 3-mm section thickness and 4 x 2.5-mm detector collimation were detected with 1.25-mm section thickness and 10 mAs. CONCLUSION: A narrow detector collimation with thin-section imaging (4 x 1.0-mm detector collimation, 1.25-mm section thickness) is a prerequisite for low-dose (10-mAs) multi-detector row CT colonography.

Artifacts↗

Mycobacterium avium subsp. paratuberculosis infection in a patient with HIV, Germany.

Mycobacterium avium subsp. paratuberculosis (MAP), the causative agent of Johne disease in ruminants, has been incriminated as the cause of Crohn disease in humans. We report the first case of human infection with MAP in a patient with HIV; infection was confirmed by obtaining isolates from several different specimen types.

AIDS-Related Opportunistic Infections↗