PubMed Health⌕ Search

Biomedical subjects

John A Kennedy

Publications and source records attributed to John A Kennedy.

2 recordsLinked to original sources

A hybrid algorithm for PET/CT image merger in hybrid scanners.

PURPOSE: To improve the PET image quality of a hybrid PET/CT scanner by merging CT borders with PET texture. PET/CT scanners provide both high-resolution CT images showing anatomical details and PET images of low-resolution physiological information about radiopharmaceutical uptake. Standard smoothing of noisy PET images may further impair PET resolution, reducing small lesion detectability. METHODS: The CT edge data and the PET texture data were merged using a modified form of an algorithm called HCT (hybrid computed tomography). In merged PET/CT images, each PET pixel value was estimated by iteratively applying a corrected 2D Taylor expansion to each of its eight neighbors. The spatial derivative term was used only near anatomical edges provided by the CT. This counts-preserving algorithm was tested on a special resolution phantom and patient data sets obtained by PET/CT acquisitions. RESULTS: The HCT algorithm provided phantom PET images with sharp borders and improved resolution (< or = 3 mm as compared to > or = 4 mm). HCT increased the signal to background contrast ratios by an average of 61% (40-89%) while maintaining noise reduction similar to the Gaussian filtering standard in PET. In the clinical PET images, HCT allowed for an improved delineation of pulmonary and pelvic lesions and an improved visualization of the brain. CONCLUSION: A new reconstruction algorithm for merging CT anatomical edge data with functional PET data has been introduced. The algorithm smooths noisy PET images while retaining sharper edges at corresponding anatomical borders, resulting in an improvement in resolution and contrast ratio.

Algorithms↗

Super-resolution in PET imaging.

This paper demonstrates a super-resolution method for improving the resolution in clinical positron emission tomography (PET) scanners. Super-resolution images were obtained by combining four data sets with spatial shifts between consecutive acquisitions and applying an iterative algorithm. Super-resolution attenuation corrected PET scans of a phantom were obtained using the two-dimensional and three-dimensional (3-D) acquisition modes of a clinical PET/computed tomography (CT) scanner (Discovery LS, GEMS). In a patient study, following a standard 18F-FDG PET/CT scan, a super-resolution scan around one small lesion was performed using axial shifts without increasing the patient radiation exposure. In the phantom study, smaller features (3 mm) could be resolved axially with the super-resolution method than without (6 mm). The super-resolution images had better resolution than the original images and provided higher contrast ratios in coronal images and in 3-D acquisition transaxial images. The coronal super-resolution images had superior resolution and contrast ratios compared to images reconstructed by merely interleaving the data to the proper axial location. In the patient study, super-resolution reconstructions displayed a more localized 18F-FDG uptake. A new approach for improving the resolution of PET images using a super-resolution method has been developed and experimentally confirmed, employing a clinical scanner. The improvement in axial resolution requires no changes in hardware.

Algorithms↗