PubMed Health⌕ Search

Biomedical subjects

John A McLean

Publications and source records attributed to John A McLean.

7 recordsLinked to original sources

Size-selected (2-10 nm) gold nanoparticles for matrix assisted laser desorption ionization of peptides.

In this report, first use of size-selected gold nanoparticles (AuNPs) as matrixes for matrix assisted laser desorption/ionization (MALDI) is described for peptides and proteins. In comparison with conventional organic acid MALDI matrixes, the optimum matrix-to-analyte ratio with AuNP matrixes is reduced by 10-14 orders of magnitude. Significant differences in the relative abundances of the ions observed in positive and negative mode MALDI-time-of-flight mass spectrometry (TOFMS) are revealed as the AuNP size distribution is decreased from 10 to 2 nm, whereby 2-nm AuNPs exhibit quantum confinement effects prevalent in quantum dots. AuNP matrixes allow for selective analyte ionization, as demonstrated in the selective MALDI-TOFMS of phosphotyrosine in a background of phosphoserine and phosphothreonine peptides.

Gold↗

The influence and utility of varying field strength for the separation of tryptic peptides by ion mobility-mass spectrometry.

The influence of field strength on the separation of tryptic peptides by drift tube-based ion mobility-mass spectrometry is reported. Operating the ion mobility drift tube at elevated field strengths (expressed in V cm(-1) torr(-1)) reduces separation times and increases ion transmission efficiencies. Several accounts in the literature suggest that performing ion mobility separation at elevated field strength can change the selectivity of ion separation. To evaluate the field strength dependant selectivity of ion mobility separation, we examined a data set of 65 singly charged tryptic peptide ion signals (mass range 500-2500 m/z) at six different field strengths and four different drift gas compositions (He, N2, Ar, and CH4). Our results clearly illustrate that changing the field strength from low field (15 V cm(-1) torr(-1)) to high field (66 V cm(-1) torr(-1)) does not significantly alter the selectivity or peak capacity of IM-MS. The implications of these results are discussed in the context of separation methodologies that rely on the field strength dependence of ion mobility for separation selectivity, e.g., high-field asymmetric ion mobility spectrometry (FAIMS).

Amino Acid Sequence↗

Peak capacity of ion mobility mass spectrometry: the utility of varying drift gas polarizability for the separation of tryptic peptides.

Ion mobility mass spectrometry (IM-MS) peptide mass mapping experiments were performed using a variety of drift gases (He, N2, Ar and CH4). The drift gases studied cover a range of polarizabilities ((0.2-2.6) x 10(-24) cm3) and the peak capacities obtained for tryptic peptides in each gas are compared. Although the different gases exhibit similar peak capacities (5430 (Ar) to 7580 (N2)) in some cases separation selectivity presumably based on peptide conformers (or conformer populations), is observed. For example the drift time profiles observed for some tryptic peptide ions from aldolase (rabbit muscle) show a dependence on drift gas. The transmission of high-mass ions (m/z > 2000) is also influenced by increased scattering cross-section of the more massive drift gases. Consequently the practical peak capacity for IM-MS separation cannot be assumed to be solely a function of resolution and the ability of a gas to distribute signals in two-dimensional space; rather, peak capacity estimates must account for the transmission losses experienced for peptide ions as the drift gas mass increases.

Animals↗

Determination of depleted uranium in urine via isotope ratio measurements using large-bore direct injection high efficiency nebulizer-inductively coupled plasma mass spectrometry.

Inductively coupled plasma mass spectrometry (ICP-MS), coupled with a large-bore direct injection high efficiency nebulizer (LB-DIHEN), was utilized to determine the concentration and isotopic ratio of uranium in 11 samples of synthetic urine spiked with varying concentrations and ratios of uranium isotopes. Total U concentrations and (235)U/(238)U isotopic ratios ranged from 0.1 to 10 microg/L and 0.0011 and 0.00725, respectively. The results are compared with data from other laboratories that used either alpha-spectrometry or quadrupole-based ICP-MS with a conventional nebulizer-spray chamber arrangement. Severe matrix effects due to the high total dissolved solid content of the samples resulted in a 60 to 80% loss of signal intensity, but were compensated for by using (233)U as an internal standard. Accurate results were obtained with LB-DIHEN-ICP-MS, allowing for the positive identification of depleted uranium based on the (235)U/(238)U ratio. Precision for the (235)U/(238)U ratio is typically better than 5% and 15% for ICP-MS and alpha-spectrometry, respectively, determined over the concentrations and ratios investigated in this study, with the LB-DIHEN-ICP-MS system providing the most accurate results. Short-term precision (6 min) for the individual (235)U and (238)U isotopes in synthetic urine is better than 2% (N = 7), compared to approximately 5% for conventional nebulizer-spray chamber arrangements and >10% for alpha-spectrometry. The significance of these measurements is discussed for uranium exposure assessment of Persian Gulf War veterans affected by depleted uranium ammunitions.

Aerosols↗

A high repetition rate (1 kHz) microcrystal laser for high throughput atmospheric pressure MALDI-quadrupole-time-of-flight mass spectrometry.

Sample throughput has been increased in many areas of proteomics, but the last significant advance in lasers used for matrix-assisted laser desorption/ionization (MALDI) was the introduction of cartridge-type N2 lasers (337 nm, 4-ns pulse widths, 1-30-Hz repetition rates) more than a decade ago. This report describes the application of a 1-kHz repetition rate Nd:YAG laser (355 nm, <500-ps pulse widths) for atmospheric pressure MALDI-QqTOFMS, and data obtained are compared to a conventional nitrogen laser. For example, the signal intensity for angiotensin II using the 1-kHz laser was in some cases enhanced by a factor of 80 and high-quality data could be obtained in as little as 1 s.

Journal Article↗

Oligonucleotide analysis with MALDI-ion-mobility-TOFMS.

Matrix-assisted laser-desorption ionization followed by ion-mobility separation and time-of-flight mass analysis (MALDI-IM-TOFMS) has been used to characterize native and chemically modified DNA oligonucleotides up to eight bases in length. Mobility resolution between 20 and 30 can be used to separate oligonucleotides of different length, but not to differentiate between isomers or even different compositions of the same length. MALDI-IM-TOFMS does, however, have additional utility in the analysis of mixtures of DNA oligonucleotides and peptides, because these classes of molecules can be distinguished on the basis of differences in their mobility. Oligonucleotide sequencing is also possible by MALDI-IM-TOFMS. Ion signals corresponding to nucleobase losses, w-type, and y-type fragments were identified by use of differences in ion mobility. MALDI-IM-TOFMS was also used to resolve DNA-platinum adducts from the corresponding unmodified oligonucleotides.

Ions↗

Sub-femtomole peptide detection in ion mobility-time-of-flight mass spectrometry measurements.

Sensitivity and detection limit enhancements are obtained for peptides by performing high repetition rate (150 Hz) matrix-assisted laser desorption/ionization (MALDI) coupled with ion mobility-time-of-flight mass spectrometry. Absolute limits of detection (3sigma) for model peptides are on the order of 0.1 fmol of peptide deposited and represent a factor of 40-60 improvement over data obtained using typical low repetition (20 Hz) MALDI. This increase in sensitivity is demonstrated for two-dimensional MALDI-IM-TOFMS peptide mass mapping of bovine hemoglobin.

Angiotensin I↗