PubMed Health⌕ Search

Biomedical subjects

John E P Syka

Publications and source records attributed to John E P Syka.

8 recordsLinked to original sources

Supplemental activation method for high-efficiency electron-transfer dissociation of doubly protonated peptide precursors.

Electron-transfer dissociation (ETD) delivers the unique attributes of electron capture dissociation to mass spectrometers that utilize radio frequency trapping-type devices (e.g., quadrupole ion traps). The method has generated significant interest because of its compatibility with chromatography and its ability to: (1) preserve traditionally labile post-translational modifications (PTMs) and (2) randomly cleave the backbone bonds of highly charged peptide and protein precursor ions. ETD, however, has shown limited applicability to doubly protonated peptide precursors, [M + 2H]2+, the charge and type of peptide most frequently encountered in "bottom-up" proteomics. Here we describe a supplemental collisional activation (CAD) method that targets the nondissociated (intact) electron-transfer (ET) product species ([M + 2H]+*) to improve ETD efficiency for doubly protonated peptides (ETcaD). A systematic study of supplementary activation conditions revealed that low-energy CAD of the ET product population leads to the near-exclusive generation of c- and z-type fragment ions with relatively high efficiency (77 +/- 8%). Compared to those formed directly via ETD, the fragment ions were found to comprise increased relative amounts of the odd-electron c-type ions (c+*) and the even-electron z-type ions (z+). A large-scale analysis of 755 doubly charged tryptic peptides was conducted to compare the method (ETcaD) to ion trap CAD and ETD. ETcaD produced a median sequence coverage of 89%-a significant improvement over ETD (63%) and ion trap CAD (77%).

Amino Acid Sequence↗

The utility of ETD mass spectrometry in proteomic analysis.

Mass spectrometry has played an integral role in the identification of proteins and their post-translational modifications (PTM). However, analysis of some PTMs, such as phosphorylation, sulfonation, and glycosylation, is difficult with collision-activated dissociation (CAD) since the modification is labile and preferentially lost over peptide backbone fragmentation, resulting in little to no peptide sequence information. The presence of multiple basic residues also makes peptides exceptionally difficult to sequence by conventional CAD mass spectrometry. Here we review the utility of electron transfer dissociation (ETD) mass spectrometry for sequence analysis of post-translationally modified and/or highly basic peptides. Phosphorylated, sulfonated, glycosylated, nitrosylated, disulfide bonded, methylated, acetylated, and highly basic peptides have been analyzed by CAD and ETD mass spectrometry. CAD fragmentation typically produced spectra showing limited peptide backbone fragmentation. However, when these peptides were fragmented using ETD, peptide backbone fragmentation produced a complete or almost complete series of ions and thus extensive peptide sequence information. In addition, labile PTMs remained intact. These examples illustrate the utility of ETD as an advantageous tool in proteomic research by readily identifying peptides resistant to analysis by CAD. A further benefit is the ability to analyze larger, non-tryptic peptides, allowing for the detection of multiple PTMs within the context of one another.

Amino Acid Sequence↗

Protein identification using sequential ion/ion reactions and tandem mass spectrometry.

A method for rapid sequencing of intact proteins simultaneously from the N and C termini (1-2 s) with online chromatography is described and applied to the characterization of histone H3.1 posttranslational modifications and the identification of an additional member of the H2A gene family. Proteins are converted to gas-phase multiply charged positive ions by electrospray ionization and then allowed to react with fluoranthene radical anions. Electron transfer to the multiply charged protein promotes random dissociation of the N-Calpha bonds of the protein backbone. Multiply charged fragment ions are then deprotonated in a second ion/ion reaction with the carboxylate anion of benzoic acid. The m/z values for the resulting singly and doubly charged ions are used to read a sequence of 15-40 aa at both the N and C termini of the protein. This information, with the measured mass of the intact protein, is used to search protein or nucleotide databases for possible matches, detect posttranslational modifications, and determine possible splice variants.

Chromatography, High Pressure Liquid↗

Electron transfer dissociation of peptide anions.

Ion/ion reactions of multiply deprotonated peptide anions with xenon radical cations result in electron abstraction to generate charge-reduced peptide anions containing a free-radical site. Peptide backbone cleavage then occurs by hydrogen radical abstraction from a backbone amide N to facilitate cleavage of the adjacent C-C bond, thereby producing a- and x-type product ions. Introduction of free-radical sites to multiply charged peptides allows access to new fragmentation pathways that are otherwise too costly (e.g., lowers activation energies). Further, ion/ion chemistry, namely electron transfer reactions, presents a rapid and efficient means of generating odd-electron multiply charged peptides; these reactions can be used for studying gas-phase chemistries and for peptide sequence analysis.

Amino Acid Sequence↗

Peptide and protein sequence analysis by electron transfer dissociation mass spectrometry.

Peptide sequence analysis using a combination of gas-phase ion/ion chemistry and tandem mass spectrometry (MS/MS) is demonstrated. Singly charged anthracene anions transfer an electron to multiply protonated peptides in a radio frequency quadrupole linear ion trap (QLT) and induce fragmentation of the peptide backbone along pathways that are analogous to those observed in electron capture dissociation. Modifications to the QLT that enable this ion/ion chemistry are presented, and automated acquisition of high-quality, single-scan electron transfer dissociation MS/MS spectra of phosphopeptides separated by nanoflow HPLC is described.

Amino Acid Sequence↗

A two-dimensional quadrupole ion trap mass spectrometer.

The use of a linear or two-dimensional (2-D) quadrupole ion trap as a high performance mass spectrometer is demonstrated. Mass analysis is performed by ejecting ions out a slot in one of the rods using the mass selective instability mode of operation. Resonance ejection and excitation are utilized to enhance mass analysis and to allow isolation and activation of ions for MS(n) capability. Improved trapping efficiency and increased ion capacity are observed relative to a three-dimensional (3-D) ion trap with similar mass range. Mass resolution comparable to 3-D traps is readily achieved, including high resolution at slower scan rates, although adequate mechanical tolerance of the trap structure is a requirement. Additional advantages of 2-D over 3-D ion traps are also discussed and demonstrated.

Journal Article↗

Novel linear quadrupole ion trap/FT mass spectrometer: performance characterization and use in the comparative analysis of histone H3 post-translational modifications.

We describe the design and performance of a prototype high performance hybrid mass spectrometer. This instrument consists of a linear quadrupole ion trap (QLT) coupled to a Fourier transform ion cyclotron resonance mass analyzer (FTMS). This configuration provides rapid and automated MS and MS/MS analyses, similar to the "data dependent scanning" found on standard 3-D Paul traps, but with substantially improved internal scan dynamic range, mass measurement accuracy, mass resolution, and detection limits. Sequence analysis of peptides at the zeptomole level is described. The recently released, commercial version of this instrument operates in the LC/MS mode (1 s/scan) with a mass resolution of 100 000 and is equipped with automatic gain control to provide mass measurement accuracy of 1-2 ppm without internal standard. Methodology is described that uses this instrument to compare the post-translational modifications present on histone H3 isolated from asynchronously growing cells and cells arrested in mitosis.

Amino Acid Sequence↗