PubMed Health⌕ Search

Biomedical subjects

John Entwistle

Publications and source records attributed to John Entwistle.

5 recordsLinked to original sources

Initial experience with the AbioCor implantable replacement heart system.

OBJECTIVE: We sought to evaluate the safety and efficacy of the first available totally implantable replacement heart (AbioCor Implantable Replacement Heart System) in the treatment of severe, irreversible biventricular heart failure in human patients. METHODS: Seven male adult patients with severe, irreversible biventricular failure (>70% thirty-day predicted mortality) who were not candidates for transplantation met all institutional review board study criteria and had placement of the AbioCor Implantable Replacement Heart. All were in cardiogenic shock despite maximal medical therapy, including inotropes and intra-aortic balloon pumps. Mean age was 66.7 +/- 10.4 years (range, 51-79 years). Four of 7 patients had prior operations. Six had ischemic and one had idiopathic cardiomyopathy. All had 3-dimensional computer-simulated implantation of the thoracic unit that predicted adequate fit. At the time of the operation, the internal transcutaneous energy transfer coil, battery, and controller were placed. Biventriculectomy was then performed, and the thoracic unit was placed in an orthotopic position and attached to the atrial cuffs and outflow conduits with quick-connects. The flow was adjusted to 4 to 8 L/min. Central venous and left atrial pressures were maintained at 5 to 15 mm Hg. The device is powered through transcutaneous energy transfer. An atrial flow-balancing chamber is used to adjust left/right balance. The balance chamber and transcutaneous energy transfer eliminate the need for percutaneous lines. RESULTS: There was one intraoperative death caused by coagulopathic bleeding and one early death caused by an aprotinin reaction. There have been multiple morbidities primarily related to preexisting illness severity: 5 patients had prolonged intubation, 2 had hepatic failure (resolved in 1), 4 had renal failure (resolved in 3), and 1 each had recurrent gastrointestinal bleeding, acute cholecystitis requiring laparotomy, respiratory failure that resolved after 3 days of extracorporeal membrane oxygenation, and malignant hyperthermia (resolved). There were 3 late deaths: one caused by multiple systems organ failure (postoperative day 56), one caused by a cerebrovascular accident (postoperative day 142), and one caused by retroperitoneal bleeding and resultant multiple systems organ failure (postoperative day 151). This latter patient was not able to tolerate anticoagulation (no anticoagulation or antiplatelet therapy alone for 80% of the first 60 days) and had a transient ischemic attack on postoperative day 61 and a cerebrovascular accident on postoperative day 130. At autopsy, blood pumps were clean. The 2 patients who had large cerebrovascular accidents had thrombus on the atrial cage struts. These struts have been removed for future implants. There has been no significant hemolysis or device-related infections. The balance chamber has allowed for left/right balance in all patients (left atrial pressure within 5 mm Hg of right atrial pressure). Three patients have taken multiple (>50) trips out of the hospital, and 2 have been discharged from the hospital. Total days on support with the AbioCor are 759. CONCLUSION: The initial clinical experience suggests that the AbioCor might be effective therapy in patients with advanced biventricular failure. There have been no significant device malfunctions. Two of these patients have been discharged from the hospital.

Aged↗

The AbioCor implantable replacement heart.

The AbioCor implantable replacement heart (IRH) is the first available totally implantable artificial heart. We recently initiated a multicenter trial of this device in patients with severe, irreversible biventricular failure. Patients who were not candidates for other therapies, including transplantation, were evaluated. All candidates were adults with inotrope-dependent biventricular failure, whose 30-day predicted mortality was higher than 70%. A three-dimensional computerized fit study predicted fit of the AbioCor thoracic unit in all recipients. At operation, the internal battery controller and transcutaneous energy transfer unit were placed. The AbioCor thoracic unit was placed in an orthotopic position after incision of the ventricals. There were 2 intraoperative deaths (due to intraoperative bleeding or aprotinin reaction). Four late deaths were recorded, 1 from multisystem organ failure and 3 cerebrovascular accidents. Autopsy revealed thrombus on the atrial struts of the 3 patients with cerebrovascular accident. Blood pumps and valves were clean on all patients. Significant morbidity was observed, primarily related to preexisting severity of illness. However, 3 patients recovered to the point of being able to take multiple trips outside of the hospital. Two patients were discharged from the hospital, with 1 patient being discharged home for more than 7 months. No significant device malfunctions or multi-system organ failure device-related infections were noted. The AbioCor IRH may be effective therapy for patients with end-stage heart failure. Many milestones have been achieved in the initial trial in humans, including the successful discharge of a patient to home and no significant device malfunctions. The occurrence of stroke is likely related to the presence of thrombus on the atrial struts and may be decreased as these atrial struts have been removed for future clinical implants.

Aged↗

Delineation of intracardiac shunts using contrast echocardiography.

Contrast echocardiography is useful to visualize the endocardial borders of the left ventricle and improve the signal intensity of spectral Doppler signals. It can also help to define intracardiac flow dynamics in complex situations. We report 2 cases where contrast echocardiography improved the delineation of complex shunts and also provided new information not available by conventional echocardiography.

Adult↗

Clinical use of the abiomed BVS 5000 as a pulsatile extracorporeal membrane oxygenation unit.

The traditional extracorporeal membrane oxygenation circuit uses a centrifugal pump. These pumps require close monitoring and are subject to complications. In addition, they do not take advantage of the potential benefits of pulsatile flow. These extracorporeal membrane oxygenation circuits use a single pump with an inline oxygenator. If cardiac failure persists after respiratory recovery has occurred, removal of the oxygenator requires an additional procedure to convert the patient to biventricular support. This report describes a circuit in which an oxygenator is connected to a pulsatile ventricular assist device. Single and dual circuit configurations are illustrated. Recommendations for pulmonary care during support are also described.

Angioplasty↗