Radiation doses in interventional radiology procedures: the RAD-IR study: part I: overall measures of dose.

PURPOSE: To determine patient radiation doses for interventional radiology and neuroradiology procedures, to identify procedures associated with higher radiation doses, and to determine the effects of various parameters on patient doses. MATERIALS AND METHODS: A prospective observational study was performed at seven academic medical centers. Each site contributed demographic and radiation dose data for subjects undergoing specific procedures in fluoroscopic suites equipped with built-in cumulative dose (CD) and dose-area-product (DAP) measurement capability compliant with International Electrotechnical Commission standard 60601-2-43. The accuracy of the dosimetry was confirmed by comprehensive measurements and by frequent consistency checks performed over the course of the study. RESULTS: Data were collected on 2,142 instances of interventional radiology procedures, 48 comprehensive physics evaluations, and 581 periodic consistency checks from the 12 fluoroscopic units in the study. There were wide variations in dose and statistically significant differences in fluoroscopy time, number of images, DAP, and CD for different instances of the same procedure, depending on the nature of the lesion, its anatomic location, and the complexity of the procedure. For the 2,142 instances, observed CD and DAP correlate well overall (r = 0.83, P <.000001), but correlation in individual instances is poor. The same is true for the correlation between fluoroscopy time and CD (r = 0.79, P <.000001). The correlation between fluoroscopy time and DAP (r = 0.60, P <.000001) is not as good. In 6% of instances (128 of 2,142), which were principally embolization procedures, transjugular intrahepatic portosystemic shunt (TIPS) procedures, and renal/visceral artery stent placements, CD was greater than 5 Gy. CONCLUSIONS: Most procedures studied can result in clinically significant radiation dose to the patient, even when performed by trained operators with use of dose-reducing technology and modern fluoroscopic equipment. Embolization procedures, TIPS creation, and renal/visceral artery stent placement are associated with a substantial likelihood of clinically significant patient dose. At minimum, patient dose data should be recorded in the medical record for these three types of procedures. These data should include indicators of the risk of deterministic effects as well as the risk of stochastic effects.

Adolescent↗

Radiation doses in interventional radiology procedures: the RAD-IR study: part II: skin dose.

PURPOSE: To determine peak skin dose (PSD), a measure of the likelihood of radiation-induced skin effects, for a variety of common interventional radiology and interventional neuroradiology procedures, and to identify procedures associated with a PSD greater than 2 Gy. MATERIALS AND METHODS: An observational study was conducted at seven academic medical centers in the United States. Sites prospectively contributed demographic and radiation dose data for subjects undergoing 21 specific procedures in a fluoroscopic suite equipped with built-in dosimetry capability. Comprehensive physics evaluations and periodic consistency checks were performed on each unit to verify the stability and consistency of the dosimeter. Seven of 12 fluoroscopic suites in the study were equipped with skin dose mapping software. RESULTS: Over a 3-year period, skin dose data were recorded for 800 instances of 21 interventional radiology procedures. Wide variation in PSD was observed for different instances of the same procedure. Some instances of each procedure we studied resulted in a PSD greater than 2 Gy, except for nephrostomy, pulmonary angiography, and inferior vena cava filter placement. Some instances of transjugular intrahepatic portosystemic shunt (TIPS) creation, renal/visceral angioplasty, and angiographic diagnosis and therapy of gastrointestinal hemorrhage produced PSDs greater than 3 Gy. Some instances of hepatic chemoembolization, other tumor embolization, and neuroembolization procedures in the head and spine produced PSDs greater than 5 Gy. In a subset of 709 instances of higher-dose procedures, there was good overall correlation between PSD and cumulative dose (r = 0.86; P <.000001) and between PSD and dose-area-product (r = 0.85, P <.000001), but there was wide variation in these relationships for individual instances. CONCLUSIONS: There are substantial variations in PSD among instances of the same procedure and among different procedure types. Most of the procedures observed may produce a PSD sufficient to cause deterministic effects in skin. It is suggested that dose data be recorded routinely for TIPS creation, angioplasty in the abdomen or pelvis, all embolization procedures, and especially for head and spine embolization procedures. Measurement or estimation of PSD is the best method for determining the likelihood of radiation-induced skin effects. Skin dose mapping is preferable to a single-point measurement of PSD.

Fluoroscopy↗