PubMed Health⌕ Search

Biomedical subjects

John G Georgiadis

Publications and source records attributed to John G Georgiadis.

2 recordsLinked to original sources

Extraction and validation of correlation lengths from interstitial velocity fields using diffusion-weighted MRI.

Magnetic Resonance Imaging methods sensitive to individual molecular displacements (q-space MRI) provide a convenient means of measuring dispersion in complex interstitial spaces. Pressure-driven flow experiments through a water-saturated packed bed phantom have been conducted to prove the feasibility of using q-space MRI to measure the coherence length associated with the interstitial velocity field. The method involves measuring the dependence of the apparent dispersion coefficient on the distance along the mean flow by repeating a small number of pulsed-gradient stimulated-echo experiments with increasing gradient pulse separation times. Assuming homogeneous interstitial flow statistics inside the averaging volume, an integral spatial scale characterizing the Eulerian velocity auto-correlation coefficient is extracted via a stochastic convective model. The validity of the a priori statistical description of interstitial flow is verified by comparing with an independent MRI measurement of the Eulerian velocity field using phase contrast methods in the same phantom with pore-level resolution. The integral length scale obtained via q-space MRI agrees with the mean pore size in the present as well as in similar phantoms found in the literature. This method has direct applicability in the quantification of the interstitial morphology of fluid-saturated porous media with resolution independent of voxel size, assuming "perfectly reflecting pore walls" (no surface relaxation) and no contribution to the MR signal from outside the pore space.

Diffusion Magnetic Resonance Imaging↗

Synchronized EPI phase contrast velocimetry in a mixing reactor.

Notwithstanding its widespread use in cardiovascular and functional MRI studies, Echo Planar Imaging (EPI) has only recently been subjected to systematic validation studies. Most velocity measurement studies employing such ultrafast MRI methods involve the use of phantoms characterized by rigid or deformable solid motion. The current implementation involves a rotating phantom (angular velocity up to 10.5 rpm) with a superimposed swirling liquid flow (with axial velocities ranging between 0.145 and 0.27 cm/s) of water doped with copper sulfate. The standard implementation of single-shot EPI with phase contrast velocity encoding allows the complete mapping of the Eulerian velocity field in slices perpendicular to the rotation axis following a subtractive procedure requiring the synchronized acquisition of each velocity component on each selected transverse slice during two revolutions of the rotor. The image acquisition time is 100 ms (per velocity component) at each 64 x 64 slice. In addition to acquiring full-field velocity data for future direct comparisons with other techniques, EPI is employed here for the first time to reconstruct the three-dimensional flow field between the blades of a partitioned pipe mixer.

Echo-Planar Imaging↗