PubMed Health⌕ Search

Biomedical subjects

John Georg Seland

Publications and source records attributed to John Georg Seland.

4 recordsLinked to original sources

Determination of water compartments in rat myocardium using combined D-T1 and T1-T2 experiments.

We have used combined D-T1 and T1-T2 correlation experiments to explore water compartments in rat heart tissue (myocardium). The results show that two main compartments can be identified, which we assign to extracellular (ec) and intracellular (ic) water. The exchange rate of water across the cell membrane was found to be on the order of 0.1 Hz. In addition, the T1-T2 correlation measurements indicate that the ic compartment contain two T2 populations.

Animals↗

Correlations between diffusion, internal magnetic field gradients, and transverse relaxation in porous systems containing oil and water.

The main focus in this study is to investigate the correlations between internal magnetic field gradients (G0) and transverse relaxation times in liquid-saturated packings of glass beads of different wettabilities. We show how these correlations can be expressed as two-dimensional (2D) diagrams of distribution functions between internal magnetic field gradients and T2 values. In the case where it is difficult to distinguish the signals from oil and water, we separate them based on their difference in diffusivity. In addition to using such diffusion weighting in the G0-T2 diagrams, we also show results from experiments where the direct correlation between diffusion and T2 (D-T2) is determined. The overall results show that the wettability of the glass beads has a strong influence on the appearance of these diagrams, in particular on the location of the fast diffusing water molecules. However, due to their lower diffusivity, the transverse magnetization of the oil molecules is not so greatly influenced by either the presence of the glass beads or their wettability properties. Thus, the wettability properties of a liquid-filled porous material can be determined from the location of the water signal in such 2D diagrams. In particular, we show that this is the case not only for D-T2 diagrams, but also for G0-T2 diagrams.

Journal Article↗

Background gradient suppression in pulsed gradient stimulated echo measurements.

Pulsed gradient spin echo (PGSE) experiments can be used to measure the probability distribution of molecular displacements. In homogeneous samples this reports on the molecular diffusion coefficient, and in heterogeneous samples, such as porous media and biological tissue, such measurements provide information about the sample's morphology. In heterogeneous samples however background gradients are also present and prevent an accurate measurement of molecular displacements. The interference of time independent background gradients with the applied magnetic field gradients can be removed through the use of bipolar gradient pulses. However, when the background gradients are spatially non-uniform molecular diffusion introduces a temporal modulation of the background gradients. This defeats simple bipolar gradient suppression of background gradients in diffusion related measurements. Here we introduce a new method that requires the background gradients to be constant over coding intervals only. Since the coding intervals are typically at least an order of magnitude shorter than the storage time, this new method succeeds in suppressing cross-terms for a much wider range of heterogeneous samples.

Diffusion↗

A PFG-NMR Study of Restricted Diffusion in Heterogeneous Polymer Particles.

The diffusion resistance to monomers during heterogeneous polymerization of polyolefin particles may have a significant effect on the observed activity. This diffusivity is, in general, unknown. To gain more information on this diffusion resistance in such systems, PFG-NMR has been used to measure the diffusion of organic solvents in various systems of porous polymer particles. In such systems the complex morphology and geometry demands careful analysis of the PFG-NMR attenuation curve. In this study, effects from restricted diffusion, domains having different diffusivity, and internal magnetic field gradients are expected. Thus, the obtained diffusivities have to be considered carefully, and a way to analyze the data taking these effects into account is presented. Copyright 2001 Academic Press.

Journal Article↗