A novel two-dimensional echocardiographic image analysis system using artificial intelligence-learned pattern recognition for rapid automated ejection fraction.

OBJECTIVES: We sought to test the hypothesis that a novel 2-dimensional echocardiographic image analysis system using artificial intelligence-learned pattern recognition can rapidly and reproducibly calculate ejection fraction (EF). BACKGROUND: Echocardiographic EF by manual tracing is time consuming, and visual assessment is inherently subjective. METHODS: We studied 218 patients (72 female), including 165 with abnormal left ventricular (LV) function. Auto EF incorporated a database trained on >10,000 human EF tracings to automatically locate and track the LV endocardium from routine grayscale digital cineloops and calculate EF in 15 s. Auto EF results were independently compared with manually traced biplane Simpson's rule, visual EF, and magnetic resonance imaging (MRI) in a subset. RESULTS: Auto EF was possible in 200 (92%) of consecutive patients, of which 77% were completely automated and 23% required manual editing. Auto EF correlated well with manual EF (r = 0.98; 6% limits of agreement) and required less time per patient (48 +/- 26 s vs. 102 +/- 21 s; p < 0.01). Auto EF correlated well with visual EF by expert readers (r = 0.96; p < 0.001), but interobserver variability was greater (3.4 +/- 2.9% vs. 9.8 +/- 5.7%, respectively; p < 0.001). Visual EF was less accurate by novice readers (r = 0.82; 19% limits of agreement) and improved with trainee-operated Auto EF (r = 0.96; 7% limits of agreement). Auto EF also correlated with MRI EF (n = 21) (r = 0.95; 12% limits of agreement), but underestimated absolute volumes (r = 0.95; bias of -36 +/- 27 ml overall). CONCLUSIONS: Auto EF can automatically calculate EF similarly to results by manual biplane Simpson's rule and MRI, with less variability than visual EF, and has clinical potential.

Aged↗

Velocity vector imaging to quantify ventricular dyssynchrony and predict response to cardiac resynchronization therapy.

Velocity vector imaging is a novel quantitative echocardiographic technique that was applied to routine grayscale echocardiographic images of 23 patients with heart failure who underwent cardiac resynchronization therapy. The hypothesis was tested that velocity vector imaging can quantify left ventricular mechanical dyssynchrony and predict response to resynchronization therapy. Tissue velocities were determined by the automated tracking of periodic B-mode image patterns on digital cine loops from standard apical 4-chamber, 2-chamber, and long-axis views, with the user tracing the mid left ventricular wall from a single frame. Dyssynchrony was determined as the greatest opposing wall peak longitudinal systolic velocity delay from the 3 views. Responders, defined as those with >or=15% increases in the ejection fraction, had greater baseline dyssynchrony than nonresponders (opposing wall velocity delays of 131 +/- 83 vs 52 +/- 60 ms, p <0.05), and >or=75 ms predicted response with 85% sensitivity and 80% specificity when followed 8 +/- 5 months after resynchronization therapy. Baseline electrocardiographic QRS duration was not predictive in the same patients. In conclusion, echocardiographic velocity vector imaging has potential for clinical utility.

Blood Flow Velocity↗

Novel speckle-tracking radial strain from routine black-and-white echocardiographic images to quantify dyssynchrony and predict response to cardiac resynchronization therapy.

BACKGROUND: Mechanical dyssynchrony is a potential means to predict response to cardiac resynchronization therapy (CRT). We hypothesized that novel echocardiographic image speckle tracking can quantify dyssynchrony and predict response to CRT. METHODS AND RESULTS: Seventy-four subjects were studied: 64 heart failure patients undergoing CRT (aged 64+/-12 years, ejection fraction 26+/-6%, QRS duration 157+/-28 ms) and 10 normal controls. Speckle tracking applied to routine midventricular short-axis images calculated radial strain from multiple circumferential points averaged to 6 standard segments. Dyssynchrony from timing of speckle-tracking peak radial strain was correlated with tissue Doppler measures in 47 subjects (r=0.94, P<0.001; 95% CI 0.90 to 0.96). The ability of baseline speckle-tracking radial dyssynchrony (time difference in peak septal wall-to-posterior wall strain > or =130 ms) to predict response to CRT was then tested. It predicted an immediate increase in stroke volume in 48 patients studied the day after CRT with 91% sensitivity and 75% specificity. In 50 patients with long-term follow-up 8+/-5 months after CRT, baseline speckle-tracking radial dyssynchrony predicted a significant increase in ejection fraction with 89% sensitivity and 83% specificity. Patients in whom left ventricular lead position was concordant with the site of latest mechanical activation by speckle-tracking radial strain had an increase in ejection fraction from baseline to a greater degree (10+/-5%) than patients with discordant lead position (6+/-5%; P<0.05). CONCLUSIONS: Speckle-tracking radial strain can quantify dyssynchrony and predict immediate and long-term response to CRT and has potential for clinical application.

Adult↗

Effect of concordance between sites of left ventricular pacing and dyssynchrony on acute electrocardiographic and echocardiographic parameters in patients with heart failure undergoing cardiac resynchronization therapy.

BACKGROUND: Wide QRS complexes are associated with left ventricular (LV) dyssynchrony, but an optimal site of LV pacing has not been established. HYPOTHESIS: We hypothesized that concordance between the sites of LV pacing and of latest LV mechanical activation during cardiac resynchronization therapy (CRT) is associated with more favorable acute echocardiographic changes. METHODS: An analysis of 28 consecutive patients (64+/-15 years, 46% male, 52% ischemic heart disease, LV ejection fraction 0.24+/-0.07, QRS 163+/-22 ms, New York Heart Association > or = 3 93%) implanted with biventricular (BIV) defibrillators was performed. Sites of latest LV activation were determined by tissue Doppler imaging (TDI) and speckle tracking (ST). The site of LV pacing was determined by fluoroscopy in two views. A concordance score (0-5) was created to describe the proximity of the pacing site to the site of the latest mechanical activation. RESULTS: Compared with the worst concordance score, a perfect score was associated with shorter QRS width with LV (187+/-40 vs. 246+/-8 ms, p= 0.048) and BIV (134+/-19 ms vs. 179+/-39 ms, p = 0.05) but not with right ventricular pacing. A perfect concordance score was also associated with a greater acute reduction in LV volumes in systole (42+/-36 ms 16+/-22 ms, p = 0.068) and diastole (47+/-37 vs. 8+/-31 ml, p = 0.043) 24 h after CRT device implantation. CONCLUSIONS: A high concordance is associated with shorter QRS width with LV and BIV pacing and greater acute reduction in LV volumes. The effect of concordance on the intermediate and long-term response to BIV pacing deserves further evaluation.

Acute Disease↗

Effects of radial left ventricular dyssynchrony on cardiac performance using quantitative tissue Doppler radial strain imaging.

Our objective was to test the hypothesis that novel angle-corrected radial strain imaging can quantify left ventricular dyssynchrony associated with contractile impairment and improved with biventricular pacing. Eight open-chest dogs were studied by novel angle-corrected color-coded radial strain imaging and high-fidelity pressure-conductance catheters recording pressure-volume loops. Heart rate was controlled by right atrial pacing and all timing intervals were corrected by R-R interval (corrected interval = measured interval/(R-R interval)(1/2)). Left bundle branch block, simulated by right ventricular free wall pacing, resulted in marked radial dyssynchrony, which we defined as maximal time difference between peak segmental strain, from 39 +/- 17 to 354 +/- 49 milliseconds and stroke work decreased from 157 +/- 40 to 60 +/- 37 mJ, (P < .005 vs baseline). Depression of contractility by high-dose esmolol (end-systolic pressure-volume relationship from 5.7 +/- 2.4 to 3.6 +/- 1.0 mm Hg/mL) was associated with augmented dyssynchrony to 388 +/- 53 milliseconds (P < .05 vs baseline right ventricular pacing). Biventricular pacing improved dyssynchrony to 55 +/- 19 milliseconds and stroke work to 143 +/- 33 mJ (P < .05 vs right ventricular pacing). Changes in radial dyssynchrony correlated significantly with 6-site average regional strain (r = -0.93 +/- 0.05 individually, r = 0.80 overall) and stroke work (r = -0.88 +/- 0.12 individually, r = -0.82 overall). Angle-corrected radial strain imaging has clinical potential to quantify mechanical dyssynchrony and effects of biventricular pacing.

Animals↗

Cardiac resynchronization therapy: Part 1--issues before device implantation.

Cardiac resynchronization therapy (CRT) has been used extensively over the last years in the therapeutic management of patients with end-stage heart failure. Data from 4,017 patients have been published in eight large, randomized trials on CRT. Improvement in clinical end points (symptoms, exercise capacity, quality of life) and echocardiographic end points (systolic function, left ventricular size, mitral regurgitation) have been reported after CRT, with a reduction in hospitalizations for decompensated heart failure and an improvement in survival. However, individual results vary, and 20% to 30% of patients do not respond to CRT. At present, the selection criteria include severe heart failure (New York Heart Association functional class III or IV), left ventricular ejection fraction <35%, and wide QRS complex (>120 ms). Assessment of inter- and particularly intraventricular dyssynchrony as provided by echocardiography (predominantly tissue Doppler imaging techniques) may allow improved identification of potential responders to CRT. In this review a summary of the clinical and echocardiographic results of the large, randomized trials is provided, followed by an extensive overview on the currently available echocardiographic techniques for assessment of LV dyssynchrony. In addition, the value of LV scar tissue and venous anatomy for the selection of potential candidates for CRT are discussed.

Cardiac Output, Low↗

Cardiac resynchronization therapy: Part 2--issues during and after device implantation and unresolved questions.

Encouraged by the clinical success of cardiac resynchronization therapy (CRT), the implantation rate has increased exponentially, although several limitations and unresolved issues of CRT have been identified. This review concerns issues that are encountered during implantation of CRT devices, including the role of electroanatomical mapping, whether CRT implantation should be accompanied by simultaneous atrioventricular nodal ablation in patients with atrial fibrillation, procedural complications, and when to consider surgical left ventricular lead positioning. Furthermore, (echocardiographic) CRT optimization and assessment of CRT benefits after implantation are highlighted. Also, controversial issues such as the potential value of CRT in patients with mild heart failure or narrow QRS complex are addressed. Finally, open questions concerning when to combine CRT with implantable cardioverter-defibrillator therapy and the cost-effectiveness of CRT are discussed.

Atrial Fibrillation↗

Effects of modulation of left ventricular contractile state and loading conditions on tissue Doppler myocardial performance index.

The Tei index is clinically useful to quantify left ventricular (LV) function, but it requires sequential Doppler recordings from two different views. A related myocardial performance index (MPI) using tissue Doppler (TD) can be rapidly calculated from a single beat; however, its ability to quantify contractility and the effects of acute changes in loading have not been determined. Our aim was to test the hypothesis that TD MPI can quantify contractile state but is affected by acute alterations in loading, using LV pressure-volume relations in an animal model. Eight dogs were studied by using mitral annular TD, high-fidelity pressure, and conductance catheters. TD MPI was calculated as (a' - b')/b', where a' was the duration of mitral annular velocity during diastole and b' was the duration of the systolic wave. End-systolic elastance (Ees), the time constant of isovolumic relaxation (tau), and peak positive and negative first derivative of pressure (dP/dtmax and dP/dtmin, respectively) were used as measures of LV function. Data were obtained at baseline, at dobutamine and esmolol infusion to alter contractile state, and at inferior vena cava and aortic occlusion to alter preload and afterload. TD MPI decreased from 0.83 (SD 0.19) to 0.62 (SD 0.20) with dobutamine and increased to 1.19 (SD 0.26) with esmolol. TD MPI significantly correlated with dP/dtmax (r = -0.76), Ees (r = -0.68), dP/dtmin (r = 0.82), and tau (r = 0.78); however, it was affected by acute decreases in preload [from 0.83 (SD 0.19) to 1.09 (SD 0.36)] and acute increases in afterload [to 1.23 (SD 0.17)]. All the above increases and decreases and r values were significant (P < 0.05 vs. baseline). In conclusion, TD MPI can rapidly quantify alterations in LV contractile state but is affected by acute alterations in preload and afterload.

Animals↗

Myocardial recovery using ventricular assist devices: prevalence, clinical characteristics, and outcomes.

BACKGROUND: Ventricular assist devices (VADs) are important bridges to cardiac transplantation. VAD support may also function as a bridge to ventricular recovery (BTR); however, clinical predictors of recovery and long-term outcomes remain uncertain. We examined the prevalence, characteristics, and outcomes of BTR subjects in a large single center series. METHODS AND RESULTS: We implanted VADs in 154 adults at the University of Pittsburgh from 1996 through 2003. Of these implants, 10 were BTR. This included 2/80 (2.5%) ischemic patients (supported 42 and 61 days, respectively). Both subjects had surgical revascularization, required perioperative left VAD support, and were alive and transplant-free at follow up (232 and 1319 days, respectively). A larger percentage of nonischemic patients underwent BTR (8/74, 11%; age 30+/-14; 88% female; left ventricular ejection fraction 18+/-6%; supported 112+/-76 days). Three had myocarditis, 4 had post-partum cardiomyopathy (PPCM), and 1 had idiopathic cardiomyopathy. Five received biventricular support. After explantation, ventricular function declined in 2 PPCM patients who then required transplantation. Ventricular recovery in the 6 nonischemic patients surviving transplant-free was maintained (left ventricular ejection fraction 54+/-5%; follow-up 1.5+/-0.9 years). Overall, 8 of 10 BTR patients are alive and free of transplant (follow-up 1.6+/-1.1 years). CONCLUSIONS: In a large single center series, BTR was evident in 11% of nonischemic patients, and the need for biventricular support did not preclude recovery. For most BTR subjects presenting with acute inflammatory cardiomyopathy, ventricular recovery was maintained long-term. VAD support as BTR should be considered in the care of acute myocarditis and PPCM.

Acute Disease↗

Right ventricular dyssynchrony in patients with pulmonary hypertension is associated with disease severity and functional class.

BACKGROUND: Abnormalities in right ventricular function are known to occur in patients with pulmonary arterial hypertension. OBJECTIVE: Test the hypothesis that chronic elevation in pulmonary artery systolic pressure delays mechanical activation of the right ventricle, termed dyssynchrony, and is associated with both symptoms and right ventricular dysfunction. METHODS: Fifty-two patients (mean age 46 +/- 15 years, 24 patients with chronic pulmonary hypertension) were prospectively evaluated using several echocardiographic parameters to assess right ventricular size and function. In addition, tissue Doppler imaging was also obtained to assess longitudinal strain of the right ventricular wall, interventricular septum, and lateral wall of the left ventricle and examined with regards to right ventricular size and function as well as clinical variables. RESULTS: In this study, patients with chronic pulmonary hypertension had statistically different right ventricular fractional area change (35 +/- 13 percent), right ventricular end-systolic area (21 +/- 10 cm2), right ventricular Myocardial Performance Index (0.72 +/- 0.34), and Eccentricity Index (1.34 +/- 0.37) than individuals without pulmonary hypertension (51 +/- 5 percent, 9 +/- 2 cm2, 0.27 +/- 0.09, and 0.97 +/- 0.06, p < 0.005, respectively). Furthermore, peak longitudinal right ventricular wall strain in chronic pulmonary hypertension was also different -20.8 +/- 9.0 percent versus -28.0 +/- 4.1 percent, p < 0.01). Right ventricular dyssynchrony correlated very well with right ventricular end-systolic area (r = 0.79, p < 0.001) and Eccentricity Index (r = 0.83, p < 0.001). Furthermore, right ventricular dyssynchrony correlates with pulmonary hypertension severity index (p < 0.0001), World Health Organization class (p < 0.0001), and number of hospitalizations (p < 0.0001). CONCLUSION: Lower peak longitudinal right ventricular wall strain and significantly delayed time-to-peak strain values, consistent with right ventricular dyssynchrony, were found in a small heterogeneous group of patients with chronic pulmonary hypertension when compared to individuals without pulmonary hypertension. Furthermore, right ventricular dyssynchrony was associated with disease severity and compromised functional class.

Echocardiography↗

Utility of echocardiographic radial strain imaging to quantify left ventricular dyssynchrony and predict acute response to cardiac resynchronization therapy.

Echocardiographic strain imaging was used to quantify radial mechanical dyssynchrony in 38 patients who underwent cardiac resynchronization therapy. Dyssynchrony, defined as the time difference of peak radial strain in the septum versus the posterior wall, was significantly greater in patients with acute hemodynamic responses, and changes in radial dyssynchrony correlated with changes in stroke volume. A > or =130-ms difference in septal versus posterior wall peak strain when combined with a favorable left ventricular lead position was strongly predictive of immediate improvement in stroke volume with resynchronization therapy (95% sensitivity, 88% specificity), regardless of electrocardiographic QRS duration.

Aged↗

Usefulness of angle corrected tissue Doppler to assess segmental left ventricular function during dobutamine stress echocardiography in patients with and without coronary artery disease.

The application of angle correction to tissue Doppler (TD) during dobutamine stress echocardiography (DSE) extends the application of TD to all left ventricular segments, improves the differentiation of abnormal from normal segmental responses to stress, and has promise to improve its clinical utility for objectively evaluating wall motion during DSE.

Adult↗

Benefit of cardiac resynchronization therapy to a patient with a narrow QRS complex and ventricular dyssynchrony identified by tissue synchronization imaging.

This report described an 81-year-old woman with severe symptomatic heart failure, reduced ejection fraction, mitral regurgitation, and an electrocardiographic QRS width of 118 ms who had ventricular dyssynchrony identified by echocardiographic tissue synchronization imaging. Because of her severe heart failure symptoms on maximal medical therapy, referral to implant a defibrillator, and mechanical dyssynchrony, she underwent cardiac resynchronization-defibrillator therapy with lateral left ventricular lead placement. This resulted in an immediate 30% increase in stroke volume and 35% decrease in mitral regurgitation. Echocardiographic tissue synchronization imaging may play a role in identifying mechanical dyssynchrony in patients with narrow QRS duration who may potentially benefit from cardiac resynchronization therapy.

Aged, 80 and over↗

Differential exercise performance on ventricular assist device support.

BACKGROUND: Ventricular assist devices (VADs) are approved for destination therapy because they improve survival in end-stage heart failure (HF). VADs are powered pneumatically or electrically. Pneumatic and electric left ventricular assist devices (LVADs) and biventricular assist devices (BiVADs) provide excellent hemodynamic support at rest, but differences in their effects on exercise tolerance are unclear. We sought to evaluate the effect of devices with varying operating parameters on exercise capacity. METHODS: Exercise physiology data obtained during maximal exercise with on-line gas-exchange analysis were collected for 38 consecutive VAD-implanted HF patients referred for exercise testing. RESULTS: Electric LVADs were implanted in 18 patients, and pneumatic LVADs in 10 patients. Percent of predicted peak exercise oxygen consumption (VO2%) was significantly greater in pneumatic LVAD patients (52.1 +/- 11.1% vs 38.2 +/- 11.3%, p < 0.05). The 10 patients implanted with a pneumatically powered LVAD were compared to 10 patients implanted with a pneumatically powered BiVAD. LVAD-supported patients had a higher VO2% (52.1 +/- 11.1% vs 36.5 +/- 17.7%, p < 0.05). CONCLUSIONS: HF patients supported with a pneumatic LVAD appear to have better exercise tolerance than those receiving an electric LVAD. Patients on LVAD support have better exercise tolerance than BiVAD-supported patients. This highlights the importance of right ventricular function to exercise tolerance in HF patients, and may have implications for future VAD design.

Adult↗