MR imaging with remote control: feasibility study in cardiovascular disease.

The institutional review board approved this HIPAA-compliant study and waived informed consent. The purpose was to retrospectively evaluate remote control magnetic resonance (MR) imaging in complex cardiovascular procedures, whereby operational expertise was made available locally from a remote location. Thirty patients underwent cardiac (12 patients) and/or vascular (30 patients) 1.5-T MR imaging with a remote operator by using a personal computer. All patient studies were compared with 30 control studies obtained with conventional local imaging. Cardiac cine, myocardial delayed enhancement, and MR angiograms were assessed for overall image quality and motion artifact. MR angiograms were evaluated for vascular definition. Image quality was excellent in 90% (38 of 42) of remote images versus 60% (25 of 42) of control group images (P < .01). Scores for motion artifact were not significantly different (P = .11). Interactive MR imaging was successfully implemented with remote control in complex cardiovascular cases; diagnostic quality of images was superior to that of images obtained locally.

Adolescent↗

In-plane velocity encoding with coherent steady-state imaging.

Standard phase-contrast flow quantification (PC-FQ) using radiofrequency (RF) spoiled steady-state (SS) incoherent gradient-echo sequences have a relatively low signal-to-noise ratio (SNR). Unspoiled SS coherent (SSC) gradient-echo sequences have a higher intrinsic SNR and are T2/T1 weighted so that blood has a relatively large signal compared to other tissues. An SSC sequence that was modified to allow in-plane velocity encoding is presented. Velocity encoding was achieved by inverting the readout gradients. This offers the benefit that there is no resultant increase in repetition time (TR), which avoids increased sensitivity to off-resonance artifacts when conventional velocity-encoding methods using separate velocity-encoding gradients are extended to SSC sequences. The results of standard PC-FQ and the new method from in vitro experiments of constant and sinusoidal flow, and in vivo imaging of the carotid artery were compared. Vector field maps and paths obtained from particle-tracking calculations based on the velocity-encoded images were used to visualize the velocity data. The technique has the potential to increase the precision of PC-FQ measurements.

Algorithms↗

Muscle kinematics during isometric contraction: development of phase contrast and spin tag techniques to study healthy and atrophied muscles.

PURPOSE: To develop and compare phase-contrast (PC) and spin-tag (ST) MR imaging techniques for accurate quantification of velocity and displacement distribution in the muscle tendon complex of the lower leg during isometric contractions under in vivo conditions, in healthy subjects and subjects with atrophy. MATERIALS AND METHODS: Techniques were developed to acquire PC and ST dynamic images, gated to the force exerted by a subject during isometric contraction. Algorithms were optimized for correction of phase shading errors. Flow velocity quantification was validated in phantoms and ex vivo rabbit muscles. Trajectories of pixels calculated from PC images were compared with those in ST images. Velocity distributions were determined in healthy muscles, those atrophied by four weeks of suspension, and during physiotherapy-induced recovery. RESULTS: The technique developed allowed acquisition of images retrospectively gated to the isometric contraction performed with the subject in the scanner. Significant phase shading errors in PC images (approximately 3 cm/second over the field of view) were reduced to the background noise level by the correction algorithm. Tissue trajectories calculated from PC images agreed very well with those from ST images both in human and excised animal tissues. Peak velocities in atrophied muscles were significantly lower compared to the preatrophy state but recovered to baseline values after six weeks of therapy. CONCLUSION: We show the feasibility of monitoring muscle velocity and tissue displacement during voluntary contractions in humans under in vivo conditions using MR tissue motion mapping methods. The clinical feasibility of this technique in monitoring atrophied muscle is also demonstrated.

Adult↗

Intraaneurysmal flow visualization by using phase-contrast magnetic resonance imaging: feasibility study based on a geometrically realistic in vitro aneurysm model.

OBJECT: The aim of this study was to evaluate the feasibility of complex intraaneurysmal flow visualization with the currently available phase-contrast magnetic resonance (MR) imaging modality. METHODS: A geometrically realistic in vitro aneurysm model, in which detailed flow velocity analysis had already been conducted using laser Doppler velocimetry was used for this in vitro hemodynamic simulation, so that the results of phase-contrast velocity measurements could be compared with the previous reliable results. On a 1.5-tesla unit, three orthogonal components of velocity were obtained using a standard two-dimensional fast low-angle shot flow quantification sequence. Three-dimensional (3D) intraaneurysmal flow structures recorded during one cardiac cycle were depicted in one midsagittal and three axial cross-sectional planes with the aid of gray scale phase-contrast velocity maps. Isovelocity contour maps and secondary flow vectors were also created based on the phase-contrast velocity maps by using MATLAB software. The isovelocity contours in those three axial sections could demonstrate the shapes of inward and outward flow areas and their alternation over one cardiac cycle. The secondary flow vectors demonstrated twin vortices within the outward flow area adjacent to the boundary layer of inward and outward flow in all axial planes. CONCLUSIONS: The phase-contrast MR imaging method was able to depict the complex 3D intraaneurysmal flow structures in the in vitro aneurysm model. Detailed 3D intraaneurysmal flow information will be obtainable in vivo after improvements are made in spatial resolution, which is expected in the near future. The capability to visualize intraaneurysmal flow structures directly with the use of noninvasive MR imaging technology will have a positive impact on future clinical practice.

Hemodynamics↗