PubMed Health⌕ Search

Biomedical subjects

John H Barker

Publications and source records attributed to John H Barker.

13 recordsLinked to original sources

Low-dose immunosuppression in a rat hind-limb transplantation model.

Composite tissue allografts (CTAs) offer an alternative to conventional reconstructive methods. However, the toxicity of the drugs that are required to prevent rejection has prevented its widespread clinical application. The purpose of this study was to determine whether a low-dose, corticosteroid-free combination regimen of tacrolimus and mycophenolate mofetil (MMF) would prevent rejection in a rat hind-limb model, with minimal toxic side effects. Three groups were used in this study. In group I, Wistar Furth (WF) rats received a syngeneic WF hind-limb. In groups II and III, WF rats received an ACI hind-limb. The latter were treated with tacrolimus-MMF. Assessment for rejection, flow cytometry, and mixed lymphocyte reactions was performed. Biopsies were taken regularly and at the time of killing. Combination therapy with low-dose tacrolimus-MMF effectively prolonged CTA survival indefinitely, with minimal side effects. Toxicity associated with immunosuppressive drugs can be avoided in a low-dose combination corticosteroid-free regimen.

Animals↗

Composite tissue allotransplantation in chimeric hosts: part I. Prevention of graft-versus-host disease.

BACKGROUND: Mixed allogeneic chimerism (MAC) has been shown to induce tolerance to composite tissue allografts (CTA). However, transplantation of unmanipulated donor-specific limbs results in severe graft-versus-host disease (GVHD). This suggests that nontolerant mature donor-derived cells in the CTA may affect the stability of chimerism, potentially resulting in GVHD. The aim of this study was to develop an approach to study and prevent GVHD in a mixed chimeric-rat hind-limb transplantation model. METHODS: [ACI-->WF] chimeras received a limb from Wistar Furth (WF) (syngeneic), Fisher (third-party), or ACI (irradiated [1,050 cGy] or nonirradiated) rats. In vitro tolerance was assessed using mixed lymphocyte reactivity (MLR) assays at the time the animals were killed. RESULTS: [ACI-->WF] chimeras with greater than 85% chimerism exhibited rejection-free survival of donor-specific hind limbs. However, 100% of these animals developed lethal GVHD 22.4+/-2.8 days after limb transplantation. [ACI-->WF] chimeras that underwent transplantation with irradiated ACI or syngeneic WF limbs showed no signs of rejection or GVHD at 5 months. Nonchimeric and third-party controls rejected limbs within 10 days. CONCLUSIONS: Conditioning of the host WF rats with 950 cGy of irradiation (sublethal, myeloablative) led to high levels of MAC without GVHD. The mature T-cell content of nonirradiated donor (ACI) limbs was sufficient to induce lethal GVHD in 100% of tolerant mixed chimeric [ACI-->WF] hosts. Irradiation of donor limbs before transplantation resulted in long-term donor-specific tolerance and prevented GVHD. These data demonstrate that (1) established chimeras could be susceptible to GVHD caused by immunocompetent donor cells transferred with the hind limb, and (2) inactivating these cells with irradiation prevents GVHD and destabilization of chimerism, and permits rejection-free graft acceptance.

Animals↗

Preconditioning of latissimus dorsi muscle flaps with monophosphoryl lipid a.

The use of dynamic myoplasty to restore function to failing organs is an exciting new application of skeletal muscle flaps. A complication of large flap elevation that can compromise flap function is ischemia-induced necrosis; one approach to minimizing this is to pretreat tissues with ischemic preconditioning. The purpose of this study was to determine whether systemic administration of monophosphoryl lipid A, a drug known to mimic late-phase ischemic preconditioning in the heart, could reduce ischemia-induced necrosis in latissimus dorsi muscle flaps. Forty latissimus dorsi muscle flaps from 20 Sprague-Dawley rats were allocated into four groups. In group I (n = 10), flaps were not preconditioned and served as controls. In group II (n = 10), flaps received ischemic preconditioning with two 30-minute periods of ischemia interspersed by 10 minutes of reperfusion. In group III (n = 10), rats received an intravenous bolus of approximately 0.3 ml of monophosphoryl lipid A vehicle only. In group IV (n = 10), rats received an intravenous bolus of 450 microg/kg of monophosphoryl lipid A and vehicle. Twenty-four hours after treatment, all latissimus dorsi muscle flaps were elevated on a single neurovascular pedicle and subjected to 4 hours of ischemia. After 72 hours of reperfusion, latissimus dorsi muscles were harvested, weighed, stained with nitroblue tetrazolium, and assessed for percent necrosis using digitized images of muscle sections and computerized planimetry. The percent necrosis in ischemic preconditioning-treated flaps (group II) was significantly reduced by 57 percent (p < 0.05) compared with control flaps (group I). The percent necrosis in flaps treated with monophosphoryl lipid A (group IV) was significantly reduced by 58 percent (p < 0.05) compared with vehicle-control flaps (group III). There was no difference in mean percent necrosis between ischemic preconditioning (group II) and monophosphoryl lipid A-treated (group IV) flaps or between ischemic preconditioning-control (group I) and monophosphoryl lipid A vehicle-control (group III) flaps. Intravenous administration of systemic monophosphoryl lipid A mimics the late-phase protective effect of ischemic preconditioning in the authors' rat latissimus dorsi muscle flap model.

Animals↗

Can angiogenesis induced by chronic electrical stimulation enhance latissimus dorsi muscle flap survival for application in cardiomyoplasty?

In cardiomyoplasty, the latissimus dorsi muscle is lifted on its primary neurovascular pedicle and wrapped around a failing heart. After 2 weeks, it is trained for 6 weeks using chronic electrical stimulation, which transforms the latissimus dorsi muscle into a fatigue-resistant muscle that can contract in synchrony with the beating heart without tiring. In over 600 cardiomyoplasty procedures performed clinically to date, the outcomes have varied. Given the data obtained in animal experiments, the authors believe these variable outcomes are attributable to distal latissimus dorsi muscle flap necrosis. The aim of the present study was to investigate whether the chronic electrical stimulation training used to transform the latissimus dorsi muscle into fatigue-resistant muscle could also be used to induce angiogenesis, increase perfusion, and thus protect the latissimus dorsi muscle flap from distal necrosis. After 14 days of chronic electrical stimulation (10 Hz, 330 microsec, 4 to 6 V continuous, 8 hours/day) of the right or left latissimus dorsi muscle (randomly selected) in 11 rats, both latissimus dorsi muscles were lifted on their thoracodorsal pedicles and returned to their anatomical beds. Four days later, the resulting amount of distal flap necrosis was measured. Also, at predetermined time intervals throughout the experiment, muscle surface blood perfusion was measured using scanning laser Doppler flowmetry. Finally, latissimus dorsi muscles were excised in four additional stimulated rats, to measure angiogenesis (capillary-to-fiber ratio), fiber type (oxidative or glycolytic), and fiber size using histologic specimens. The authors found that chronic electrical stimulation (1) significantly (p < 0.05) increased angiogenesis (mean capillary-to-fiber ratio) by 82 percent and blood perfusion by 36 percent; (2) did not reduce the amount of distal flap necrosis compared with nonchronic electrical stimulation controls (29 +/- 5.3 percent versus 26.6 +/- 5.1 percent); (3) completely transformed the normally mixed (oxidative and glycolytic) fiber type distribution into all oxidative fibers; and (4) reduced fiber size in the proximal and middle but not in the distal segments of the flap. Despite the significant increase in angiogenesis and blood perfusion, distal latissimus dorsi muscle flap necrosis did not decrease. This might be because of three reasons: first, the change in muscle metabolism from anaerobic to aerobic may have rendered the muscle fibers more susceptible to ischemia. Second, because of the larger diameter of the distal fibers in normal and stimulated latissimus dorsi muscle, the diffusion distance for oxygen to the center of the distal fibers is increased, making fiber survival more difficult. Third, even though angiogenesis was significantly increased in the flap, cutting all but the single vascular pedicle resulted in the newly formed capillaries not receiving enough blood to provide nourishment to the distal latissimus dorsi muscle. The authors' findings indicate that chronic electrical stimulation as tested in these experiments could not be used to prevent distal latissimus dorsi muscle flap ischemia and necrosis in cardiomyoplasty.

Animals↗

Analysis of fiber type transformation and histology in chronic electrically stimulated canine rectus abdominis muscle island-flap stomal sphincters.

Dynamic skeletal muscle flaps are designed to perform a specific functional task through contraction and relaxation of their muscle fibers. The most commonly used dynamic skeletal flaps today are for cardiomyoplasty and anal or urinary myoplasty. Low-frequency chronic stimulation of these flaps enables them to use their intrinsic energy stores in a more efficient manner through aerobic metabolic pathways for increased endurance and improved work capacity. The purpose of this study was to (1) determine whether fiber type transformation from fatigue-prone (type II) muscle fibers to fatigue-resistant (type I) muscle fibers could be demonstrated in the authors' chronic canine stomal sphincter model where the rectus abdominis muscle was used to create a functional stomal sphincter, (2) assess whether there is any correlation between the degree of muscle fiber type transformation and the continence times, and (3) examine the long-term effects of the training regimens on the skeletal muscle fibers through histologic and volumetric analysis. Eight dynamic island-flap sphincters were created from a part of the rectus abdominis muscle in mongrel dogs by preserving the deep inferior epigastric vascular pedicle and the most caudal investing intercostal nerve. The muscular sphincters were wrapped around a blind loop of distal ileum and trained with pacing electrodes. Two different training protocols were used. In group A (n = 4), a preexisting anal dynamic graciloplasty training protocol was used. A revised protocol was used in group B (n = 4). Muscle biopsy specimens were obtained before and after training from the rectus abdominis muscle sphincter. Fiber type transformation was assessed using a monoclonal antibody directed against the fatigue-prone type II fibers. Pretraining and posttraining skeletal muscle specimens were examined histologically. A significant fiber type conversion was achieved in both group A and group B animals, with each group achieving greater than 50 percent conversion from fatigue-prone (type II) muscle fibers to fatigue-resistant (type I) muscle fibers. The continence time was different for both groups. Biopsy specimens 1 cm from the electrodes revealed that fiber type transformation was uniform throughout this region of the sphincters. Skeletal muscle fibers within both groups demonstrated a reduction in their fiber diameter and volume. Fiber type transformation is possible in this unique canine island-flap rectus abdominis sphincter model. The relative design of the flap with preservation of the skeletal muscle resting length and neuronal and vascular supply are important characteristics when designing a functional dynamic flap for stomal continence.

Animals↗

The use of end-to-side nerve grafts to reinnervate the paralyzed orbicularis oculi muscle.

Facial paralysis is a serious neurologic disorder, particularly when it affects the eye. Loss of the protective blink reflex may lead to corneal ulceration and, possibly, visual loss. The purpose of this study was to compare different nerve-grafting techniques to reanimate the paralyzed eyelid. Sixteen adult dogs (25 kg each) were allocated into four groups. Denervation of the left hemi-face was performed in all cases. One dog served as a control animal (group I). Group II dogs (n = 5) underwent end-to-side coaptation of the nerve graft to the intact palpebral branch and end-to-end coaptation to the denervated palpebral branch. Group III dogs (n = 5) underwent end-to-end coaptation of the nerve graft to the intact palpebral branch and end-to-end coaptation to the denervated palpebral branch. Group IV dogs (n = 5) underwent end-to-side coaptation of the nerve graft to the intact and denervated palpebral branches. The animals were monitored for 9 months after the surgical procedures, to allow adequate time for reinnervation. The dogs were postoperatively monitored with clinical observation, electrophysiologic testing, video motion analysis, and histologic assessments. Clinical observation and electrophysiologic testing demonstrated the production of an eye blink in the denervated hemi-face in all experimental groups. There was a trend toward increased speed of reinnervation for group III animals (end-to-end coaptations). It was concluded that end-to-side coaptation can produce a contralateral synchronous eye blink in a clinically relevant, large-animal model.

Animals↗

The efficacy of tissue factor pathway inhibitor (TFPI) as topically applied antithrombotic agent.

Tissue factor pathway inhibitor (TFPI) acts by complexing with tissue factor and factors VIIa and Xa to retard the extrinsic pathway of the coagulative process. The present study was designed to assess the antithrombotic properties of topically applied TFPI in a model of rabbit arterial thrombosis. A standardised, thrombogenic end-to-end anastomosis was made on the central ear artery. The anastomotic site was irrigated with vehicle (control, n = 5), TFPI 4 micrograms/ml (n = 8), TFPI 40 micrograms/ml (n = 8), or heparin 100 IE/ml (n = 7). The growing thrombus was observed under a stereo microscope. The image was displayed on a video monitor and recorded for analysis using computer assisted planimetry. Topical application of TFPI in either concentration or heparin did not change maximal thrombus size, mean thrombus size, or time to maximal thrombus size significantly when compared to the contralateral vehicle-treated ear. Significant anastomotic bleeding was observed in vessels treated with TFPI 40 micrograms/ml (p < 0.05).

Administration, Topical↗

Targeting of glycosaminoglycan-cytokine interactions as a novel therapeutic approach in allotransplantation.

BACKGROUND: Glycosaminoglycans (GAGs) are heteropolysaccharides present as integral components of the extracellular matrix (ECM), cell and basement membranes. GAGs play an important role in immune and inflammatory responses because of their ability to interact with cytokines and chemokines, promoting the localization of these molecules onto the ECM or cell membranes at specific anatomical sites. The main goal of these studies was to test the hypothesis that interference with the binding of cytokines/chemokines to GAGs will interfere with a graft rejection response. METHODS: MC-2, a cationic peptide derived from the sequence of the heparin-binding domain of mouse interferon gamma, was used as an inhibitor of the binding of cytokines/chemokines to GAGs. The effects of this peptide were studied in an allogeneic transplantation model involving vascularized rat skin flaps. RESULTS: The MC-2 peptide was found to inhibit binding of interferon-gamma, as well as that of the chemokines, interleukin-8, interferon gamma inducible protein-10, and regulated on activation normal T cell expressed and secreted (RANTES), to GAGs in vitro. Direct administration of MC-2 in an allogeneic skin flap transplantation model resulted in a significantly delayed time of rejection, from 5.4 +/- 0.5 days (control; n=6) to 12.6 +/- 1.6 days (treated animals; n=10). Histopathologic analysis of the skin biopsies was consistent with the delayed rejection process in those animals receiving the peptide, showing only mild signs of rejection up to day 11 (in contrast, all control animals had rejected their flaps by day 6). CONCLUSIONS: These results are consistent with the idea that GAG-cytokine interactions constitute valid therapeutic targets and suggest the potential applicability of such an approach in the prevention of graft rejection.

Animals↗

Reducing the vascular delay period in latissimus dorsi muscle flaps for use in cardiomyoplasty.

Although the mechanism by which vascular delay benefits skin flaps is not completely understood, this topic has been extensively studied and reported on in the literature. In contrast, little has been documented about the effects of vascular delay in skeletal muscle flaps. Recent animal studies tested the effectiveness of vascular delay to enhance latissimus dorsi muscle flap viability for use in cardiomyoplasty and found that it prevented distal flap necrosis. However, these studies did not define the optimal time period necessary to achieve this beneficial effect. The purpose of this study was to determine how many days of "delay" can elicit the beneficial effects of vascular delay on latissimus dorsi muscle flaps. To accomplish this, 90 latissimus dorsi muscles of 45 male Sprague-Dawley rats were randomly subjected to vascular delay on one side or a sham procedure on the other. After predetermined delay periods (0, 3, 7, 10, and 14 days) or a sham procedure, all latissimus dorsi muscles were elevated as single pedicled flaps based only on their thoracodorsal neurovascular pedicle. Latissimus dorsi muscle perfusion was measured using a Laser Doppler Perfusion Imager just before and immediately after flap elevation. The muscles were then returned to their original vascular beds, isolated from adjacent tissue with Silastic film, sutured into place to maintain their original size and shape, and left there for 5 days. After 5 days, the latissimus dorsi muscle flaps were dissected free, scanned again (Laser Doppler Perfusion Imager-perfusion measurements), and the area of distal necrosis was measured using digitized planimetry of magnified images. The authors' results showed that delay periods of 3, 7, 10, and 14 days significantly increased (p < 0.05) blood perfusion and decreased (p < 0.05) distal flap necrosis when compared with sham controls. On the basis of these findings, the authors conclude that in their rat latissimus dorsi muscle flap model the beneficial effects of vascular delay are present as early as 3 days. If these findings also hold true in humans, they could be useful in cardiomyoplasty by allowing surgeons to shorten the amount of time between the vascular delay procedure and the cardiomyoplasty procedure in these very sick patients.

Animals↗

Local heparin is superior to systemic heparin in preventing arterial thrombosis.

Thrombosis poses a significant problem in microvascular surgery, despite antithrombotic therapy. The purpose of the present study was to investigate whether a topical application of unfractionated heparin is equally efficient as a systemic bolus in avoiding thrombosis. A rat femoral artery model was used. Three different doses of systemic heparin (50, 100, and 200 U/kg) and one dose of locally administered heparin (100 U/ml) were evaluated and compared to a control group receiving isotonic saline. A thrombogenic injury, simulating poor microsurgical technique, was applied to the artery. The thrombus area was visualized by transillumination, and recorded for 60 min on video, for subsequent measurement. In addition, the level of activated partial thromboplastin time (APTT) and of anti-activated clotting factor X (aXa) was determined. Local heparin significantly reduced thrombus size as compared to isotonic saline and systemic heparin (50 and 100 U/kg). High-dose systemic heparin (200 U/kg) was equally potent, but local heparin had significantly less influence on the hemostatic parameters.

Administration, Topical↗

Comparison of the experience with acute and chronic electrically stimulated detrusor myoplasty.

AIMS: To evaluate the acute and chronic urodynamic effects of electrically stimulated detrusor myoplasty in dogs. METHODS: Eight female mongrel dogs were studied acutely and six dogs chronically (0 to 12 weeks postoperatively). Bladders were wrapped with the rectus abdominis muscle, keeping an intact blood supply and at least two intercostal nerves of the flap preserved. Bladders were electrically stimulated with bipolar electrodes inserted into the muscle. Urodynamics and post void residual were measured post operatively in the acute studies and every 2 weeks for 3 months in chronic studies. RESULTS: Acutely, the increase in intravesical pressure was 45+/-7 cm H(2)O, which resulted in a postvoid residual of 26+/-3%. In the chronic study, increases of intravesical pressure sufficient to empty the bladder during myoplasty electrical stimulation were not sustained, although detrusor compliance and flap viability were preserved. CONCLUSIONS: The electrically stimulated detrusor myoplasty worked well acutely to increase vesical pressure sufficient to empty the bladder, but the chronically stimulated myoplasty did not maintain efficient bladder emptying primarily due to electrode problems. Further studies with improved electrode material and placement are required before clinical application of the electrically stimulated detrusor myoplasty can be assessed.

Animals↗

A technique for sequential segmental neuromuscular stimulation with closed loop feedback control.

In dynamic myoplasty, dysfunctional muscle is assisted or replaced with skeletal muscle from a donor site. Electrical stimulation is commonly used to train and animate the skeletal muscle to perform its new task. Due to simultaneous tetanic contractions of the entire myoplasty, muscles are deprived of perfusion and fatigue rapidly, causing long-term problems such as excessive scarring and muscle ischemia. Sequential stimulation contracts part of the muscle while other parts rest, thus significantly improving blood perfusion. However, the muscle still fatigues. In this article, we report a test of the feasibility of using closed-loop control to economize the contractions of the sequentially stimulated myoplasty. A simple stimulation algorithm was developed and tested on a sequentially stimulated neo-sphincter designed from a canine gracilis muscle. Pressure generated in the lumen of the myoplasty neo-sphincter was used as feedback to regulate the stimulation signal via three control parameters, thereby optimizing the performance of the myoplasty. Additionally, we investigated and compared the efficiency of amplitude and frequency modulation techniques. Closed-loop feedback enabled us to maintain target pressures within 10% deviation using amplitude modulation and optimized control parameters (correction frequency = 4 Hz, correction threshold = 4%, and transition time = 0.3 s). The large-scale stimulation/feedback setup was unfit for chronic experimentation, but can be used as a blueprint for a small-scale version to unveil the theoretical benefits of closed-loop control in chronic experimentation.

Algorithms↗