The biological effectiveness of antiproton irradiation.

BACKGROUND AND PURPOSE: Antiprotons travel through tissue in a manner similar to that for protons until they reach the end of their range where they annihilate and deposit additional energy. This makes them potentially interesting for radiotherapy. The aim of this study was to conduct the first ever measurements of the biological effectiveness of antiprotons. MATERIALS AND METHODS: V79 cells were suspended in a semi-solid matrix and irradiated with 46.7MeV antiprotons, 48MeV protons, or (60)Co gamma-rays. Clonogenic survival was determined as a function of depth along the particle beams. Dose and particle fluence response relationships were constructed from data in the plateau and Bragg peak regions of the beams and used to assess the biological effectiveness. RESULTS: Due to uncertainties in antiproton dosimetry we defined a new term, called the biologically effective dose ratio (BEDR), which compares the response in a minimally spread out Bragg peak (SOBP) to that in the plateau as a function of particle fluence. This value was approximately 3.75 times larger for antiprotons than for protons. This increase arises due to the increased dose deposited in the Bragg peak by annihilation and because this dose has a higher relative biological effectiveness (RBE). CONCLUSION: We have produced the first measurements of the biological consequences of antiproton irradiation. These data substantiate theoretical predictions of the biological effects of antiproton annihilation within the Bragg peak, and suggest antiprotons warrant further investigation.

Animals↗

Patient specific quality assurance for the delivery of intensity modulated radiotherapy.

A patient specific quality assurance program has been developed to facilitate the clinical implementation of intensity modulated radiotherapy (IMRT) delivered using a micro-multileaf collimator. The methodology includes several dosimetric tasks that are performed prior to the treatment of each patient. Film dosimetry is performed for each individual field and for the multifield composite plan. Individual field measurements are performed at a depth of 5 cm in a water equivalent slab phantom; export of dose calculations from the treatment planning system is similarly specified. For the composite distribution, parameters from the patient plan are applied to an IMRT phantom, and film is exposed in an axial orientation. Distributions are compared with the aid of software developed for the specific tasks. The measured and calculated dose distributions can be superimposed and positioned graphically using move, rotate, and mirror tools, as well as by specifying isocenter coordinates and using fiducial marks. Horizontal and vertical profiles are available for analysis. Dose difference, distance-to-agreement, and gamma index, the minimum scaled multidimensional distance between a measurement and a calculation point determined in combined dose and physical distance space, are calculated along a specified isodose line and displayed. gamma provides an excellent measure of disagreement between measurement and calculation for complex intensity distributions. We specify 3% dose difference and 3 mm distance as our scaling acceptability criteria. Absolute dosimetry for each composite plan is performed using an ionization chamber. To date, excellent agreement between measurements and calculations has been observed.

Humans↗

A seed specific dose kernel method for low-energy brachytherapy dosimetry.

We describe a method for independently verifying the dose distributions from pre- and post-implant brachytherapy source distributions. Monte Carlo calculations have been performed to characterize the three-dimensional dose distribution in water phantom from a low-energy brachytherapy source. The calculations are performed in a voxelized, Cartesian coordinate geometry and normalized based upon a separate Monte Carlo calculation for the seed specific air-kerma strength to produce an absolute dose grid with units of cGy hr(-1) x U(-1). The seed-specific, three-dimensional dose grid is stored as a text file for processing using a separate visual basic program. This program requires the coordinate positions of each seed in the pre- or post-plan and sums the kernel file for a three-dimensional composite dose distribution. A kernel matrix size of 81x81x81 with a voxel size of 1.0x1.0x1.0 mm3 was chosen as a compromise between calculation time, kernel size, and truncation of the stored dose distribution as a function of radial distance from the midpoint of the seed. Good agreement is achieved for a representative pre- and post-plan comparison versus a commercial implementation of the TG-43 brachytherapy dosimetry protocol.

Algorithms↗

Dosimetric parameters for three low-energy brachytherapy sources using the Monte Carlo N-particle code.

Monte Carlo calculations have been performed for the purpose of characterizing the dosimetric properties of three brachytherapy sources. The three sources are manufactured by Syncor Pharmaceuticals Inc. and consist of two 125I seeds (BT-125-1 and BT-125-2) and one 103Pd seed (BT-103-3). The BT-125-1 and BT-125-2 seed consists of a solid palladium and silver core, respectively. A thin layer (0.5 microm) of 125I is adsorbed onto the solid core for each seed and encased within a titanium housing. The BT-103-3 seed consists of a central gold marker and four resin balls encased within a titanium housing. A thin layer of 103Pd is bonded onto each resin ball. The dosimetric properties, including the dose rate constant, radial dose function, and anisotropy were calculated in water according to the TG-43 protocol using the Monte Carlo N-Particle code. The dose rate constant was calculated to be 0.955+/-0.005 and 0.967+/-0.005 cGyh(-1) U(-1) for the BT-125-1 and BT- 125-2 seeds, respectively. A dose rate constant of 0.659+/-0.005 cGy h(-1) U(-1) was calculated for the BT-103-3 seed. Radial dose function, g(r), calculated to a distance of 10 cm, and an isotropy function, F(r, theta), calculated for radii from 0.5 to 7.0 cm, were found to be in close agreement with previously published data.

Anisotropy↗

A Monte Carlo based phase space model for quality assurance of intensity modulated radiotherapy incorporating leaf specific characteristics.

Dose calculations for intensity modulated radiation therapy (IMRT) require an accurate description of the radiation field defined by the multileaf collimator. A previously developed Monte Carlo phase space model has been modified to provide accurate dose verification for IMRT treatments on a Novalis linear accelerator. We have incorporated into the model the effects of the multileaf collimator geometry, including leaf transmission, interleaf leakage, the rounded leaf tips and the effects of leaf sequencing, as well as the beam divergence and energy variation across the field. The modified source model was benchmarked against standard depth dose and profile measurements, and the agreement between the calculation and measurement is within the AAPM Task Group No. 53 criteria for all benchmark fields used. Film dosimetry was used to evaluate the model for IMRT sequences and plans, and the ability of the model to account for leaf sequencing effects is also demonstrated.

Algorithms↗

Dosimetric parameters of three new solid core I-125 brachytherapy sources.

Monte Carlo calculations and TLD measurements have been performed for the purpose of characterizing dosimetric properties of new commercially available brachytherapy sources. All sources tested consisted of a solid core, upon which a thin layer of 125I has been adsorbed, encased within a titanium housing. The PharmaSeed BT-125 source manufactured by Syncor is available in silver or palladium core configurations while the ADVANTAGE source from IsoAid has silver only. Dosimetric properties, including the dose rate constant, radial dose function, and anisotropy characteristics were determined according to the TG-43 protocol. Additionally, the geometry function was calculated exactly using Monte Carlo and compared with both the point and line source approximations. The 1999 NIST standard was followed in determining air kerma strength. Dose rate constants were calculated to be 0.955+/-0.005, 0.967+/-0.005, and 0.962+/-0.005 cGy h(-1) x U(-1) for the PharmaSeed BT-125-1, BT-125-2, and ADVANTAGE sources, respectively. TLD measurements were in excellent agreement with Monte Carlo calculations. Radial dose function, g(r), calculated to a distance of 10 cm, and anisotropy function, F(r,theta), calculated for radii from 0.5 to 7.0 cm, were similar among all source configurations. Anisotropy constants, phi(an), were calculated to be 0.941, 0.944, and 0.960 for the three sources, respectively. All dosimetric parameters were found to be in close agreement with previously published data for similar source configurations. The MCNP Monte Carlo code appears to be ideally suited to low energy dosimetry applications.

Brachytherapy↗