PubMed Health⌕ Search

Biomedical subjects

John M Pauly

Publications and source records attributed to John M Pauly.

6 recordsLinked to original sources

Spiral magnetic resonance coronary angiography with rapid real-time localization.

A spiral high-resolution coronary artery imaging sequence (SH) interfaced with real-time localization system (RT) has been developed. A clinical study of 40 patients suspected of coronary artery disease (CAD) was conducted. Segmented k-space acquisition techniques have dominated magnetic resonance coronary angiography (MRCA) over the last decade. Although a recent multicenter trial using this technique demonstrated encouraging results, the technique was hampered by low specificity. Spiral k-space acquisition had demonstrated several advantages for MRCA. Therefore, a first clinical trial implementing spiral high-resolution coronary imaging sequence with real-time localization (SH-RT) was performed.A clinical study of 40 patients suspected of CAD undergoing X-ray angiography was conducted to analyze the clinical reliability of this novel imaging system. The SH-RT had been designed to exploit the unique capability of two imaging sequences. The RT allowed a rapid localization of the coronary arteries. Then SH achieved multislice acquisition during a short breath-hold with submillimeter resolution. The MRCA data were analyzed for scan time, anatomic coverage, image quality, and accuracy in detecting CAD. In 40 subjects, SH achieved 0.7 to 0.9 mm resolution with 14-heartbeat breath-holds. Excellent or good image quality was achieved in 78% (263/337) of the coronary segments. Blinded consensus reading among three observers generated sensitivity of 76% and specificity of 91% in the detection of CAD compared with X-ray angiography. The MRCA imaging sequence implementing a novel spiral k-space acquisition technique enabled rapid and reliable imaging of the CAD in submillimeter resolution with short breath-holds.

Adult↗

Comparison of new sequences for high-resolution cartilage imaging.

The high prevalence of osteoarthritis continues to demand improved accuracy in detecting cartilage injury and monitoring its response to different treatments. MRI is the most accurate noninvasive method of diagnosing cartilage lesions. However, MR imaging of cartilage is limited by scan time, signal-to-noise ratio (SNR), and image contrast. Recently, there has been renewed interest in SNR-efficient imaging sequences for imaging cartilage, including various forms of steady-state free-precession as well as driven-equilibrium imaging. This work compares several of these sequences with existing methods, both theoretically and in normal volunteers. Results show that the new steady-state methods increase SNR-efficiency by as much as 30% and improve cartilage-synovial fluid contrast by a factor of three. Additionally, these methods markedly decrease minimum scan times, while providing 3D coverage without the characteristic blurring seen in fast spin-echo images.

Cartilage↗

Nonlinear phase correction for navigated diffusion imaging.

Motion during diffusion-weighted imaging (DWI) introduces phase errors that can cause significant artifacts in brain images. One method of correcting these errors uses additional navigator data to measure the phase corruptions. Standard navigator methods correct for rigid-body motion but cannot correct for nonrigid deformations of the brain related to the cardiac cycle. This work derives a generalized reconstruction that corrects for nonrigid motion based on a least-squares formulation. Since this reconstruction has the disadvantage of being computationally expensive, an approximation is presented, called a refocusing reconstruction. The refocusing reconstruction is both efficient and straightforward. Each readout is multiplied in image space by the phase conjugate of the navigator image, and these rephased readouts are then summed. The conditions under which the refocusing reconstruction is sufficient are considered and methods to improve the quality of refocused images are discussed. In particular, synchronization of the acquisition to the cardiac cycle can provide data that is well-conditioned to the refocusing reconstruction without incurring the large time penalty traditionally associated with cardiac gating. These methods are applied to steady-state DWI, a promising pulse sequence that is particularly sensitive to motion-induced phase artifacts. The refocusing reconstruction is shown to significantly improve SS-DWI over standard rigid-body corrections.

Artifacts↗

MR imaging of knee cartilage with FEMR.

OBJECTIVE: Fluctuating equilibrium magnetic resonance (FEMR) is a rapid three-dimensional (3D) imaging sequence with high signal-to-noise ratio (SNR). FEMR may be useful for detecting cartilage defects in the knee. At 1.5 T, FEMR uses a TR with odd multiples of 2.2 ms for fat/water separation. With a TR of 6.6 ms, high-resolution 3D imaging of cartilage is possible. DESIGN AND PATIENTS: The knees of 10 volunteers and two patients were imaged on a GE Signa 1.5 T scanner using an extremity coil. Scans were preceded by a shimming sequence optimizing linear terms. Subjects were imaged with FEMR, proton-density fast spin-echo (PD-FSE), T2-weighted fast spin-echo (T2-FSE), and 3D fat-suppressed spoiled-gradient-recalled echo (3D-SPGR). RESULTS: SNR and contrast-to-noise efficiency measurements for cartilage using FEMR were superior to those using PD-FSE, T2-FSE, and 3D-FS-SPGR. FSE images showed bright synovial fluid with limited cartilage detail. 3D-SPGR had comparable resolution to FEMR but suboptimal cartilage/fluid contrast and longer scan times (8 min versus 2 min). Cartilage surface detail, outlined by bright synovial fluid, was best seen on the FEMR images. DISCUSSION: FEMR obtains high-resolution 3D images of the entire knee in 2 min with excellent cartilage/fluid contrast. FEMR is sensitive to field inhomogeneity and requires shimming. Surface defects are outlined by bright synovial fluid, and cartilage has higher signal-to-noise efficiency compared with PD-FSE, T2-FSE, and 3D-SPGR techniques.

Cartilage, Articular↗

Short echo time MR spectroscopic imaging of the lung parenchyma.

PURPOSE: To perform short echo time MR spectroscopic imaging of the lung parenchyma on normal volunteers. MATERIALS AND METHODS: A short echo time projection-reconstruction spectroscopic imaging sequence was implemented on a commercial 1.5T whole body MRI scanner. Images and spectra of the lung parenchyma were obtained from five normal volunteers. Breath-held spectroscopic imaging was also performed. RESULTS: Spectroscopic imaging of short-T2* species allows visualization of different anatomic structures based upon their frequency shifts. A characteristic peak from the parenchyma was seen at three ppm from water frequency. CONCLUSION: Short echo time MR spectroscopic imaging of the lung parenchyma was demonstrated in normal volunteers. This method may improve proton imaging of the lungs and add specificity to the diagnosis of pulmonary disease.

Adult↗

In vivo real-time intravascular MRI.

PURPOSE: The Magnetic resonance imaging (MRI) is an emerging technology for catheter-based imaging and interventions. Real-time MRI is a promising methodfor overcoming catheter and physiologic motion for intravascular imaging. METHODS: All imaging was performed on a 1.5 T Signa MRI scanner with high-speed gradients. Multiple catheter coils were designed and constructed, including low-profile, stub-matched coils. Coil sensitivity patterns and SNR measurements were compared. Real-time imaging was performed with an interleaved spiral sequence using a dedicated workstation, providing real-time data acquisition, image reconstruction and interactive control and display. Real-time "black-blood" imaging was achieved through incorporation of off-slice saturation pulses. The imaging sequence was tested in a continuous flow phantom and then in vivo in the rabbit aorta using a 2 mm catheter coil. RESULTS: The real-time intravascular imaging sequence achieved 120-440 micron resolution at up to 16 frames per second. Low-profile stub-tuned catheter coils achieved similar SNR to larger traditional coil designs. In the phantom experiments, addition of real-time black-blood saturation pulses effectively suppressed the flow signal and allowed visualization of the phantom wall. In vivo experiments clearly showed real-time intravascular imaging of the rabbit aortic wall with minimal motion artifacts and effective blood signal suppression. CONCLUSIONS: Real-time imaging with low-profile coil designs provides significant enhancements to intravascular MRI.

Animals↗