Novel rectangular biphasic and monophasic waveforms delivered by a radiofrequency-powered defibrillator compared with conventional capacitor-based waveforms in transvenous cardioversion of atrial fibrillation.

AIMS: To investigate the feasibility and efficacy of novel low-tilt biphasic waveforms in transvenous cardioversion of atrial fibrillation (AF), delivered by a radiofrequency-powered defibrillator. METHODS AND RESULTS: The investigation was performed in three phases in an animal model of AF: a feasibility and efficacy study (in 10 adult Large White Landrace swine), comparison with low-tilt monophasic and standard capacitor-based waveforms, and an assessment of sequential shocks delivered over several pathways (in 15 adult Suffolk sheep). Defibrillation electrodes were positioned transvenously under fluoroscopic control in the high lateral right atrium and distal coronary sinus. When multiple defibrillation pathways were tested, a third electrode was also attached to the lower interatrial septum. The electrodes were then connected to a radiofrequency (RF)-powered defibrillator or a standard defibrillator. After confirmation of successful induction of sustained AF, defibrillation was attempted. Percentage success was calculated from the effects of all shocks delivered to all the animals within each set of experiments. Of the low-tilt (RF) biphasic waveforms delivered during internal atrial cardioversion, 100% success was achieved with a 6/6 ms 100/-50 V waveform (1.45+/-0.01 J). This waveform was similar in efficacy to low-tilt (RF) monophasic waveforms (88 vs. 92% success, 1.58+/-0.01 vs. 2.67+/-0.03 J; P=NS; delivered energy 41% lower) and superior to equivalent voltage standard monophasic (50% success, 0.67+/-0.00 J; P<0.001) and biphasic waveforms (72% success, 0.69+/-0.00 J; P=0.03). Sequential shocks delivered over dual pathways did not improve the efficacy of low-tilt biphasic waveforms. CONCLUSION: A low-tilt biphasic waveform from a RF-powered defibrillator (6/6 ms 100/-50 V) is more efficacious than standard monophasic or biphasic waveforms (equivalent voltage) and is similar in efficacy to low-tilt monophasic waveforms.

Animals↗

Improved detection of acute myocardial infarction using a diagnostic algorithm based on calculated epicardial potentials.

BACKGROUND: New methods for detecting myocardial infarction in patients with suspected acute coronary syndromes are needed particularly in an era where the majority of patients with myocardial infarction present with non-diagnostic 12-lead electrocardiograms (ECG). We compared a novel epicardial diagnostic algorithm using epicardial potentials from the 80-lead body surface map with other electrocardiographic techniques in detection of myocardial infarction. METHODS: Between February 1999 and February 2001, consecutive patients (n=427) with ischemic type chest pain had an initial 12-lead ECG and body surface map recorded. Detecting myocardial infarction using an epicardial algorithm was first performed in a training set (n=213) and tested in a validation set of patients (n=214). The results from this epicardial algorithm in myocardial infarction detection were compared with the physician's interpretation of the 12-lead ECG, the body surface map algorithm (PRIME) and physician's interpretation of the body surface map. RESULTS: Myocardial infarction occurred in 205 patients (creatine kinase >or=2x upper limit of normal with creatine kinase-MB >or=7% CK). The physician's interpretation of the 12-lead ECG identified 122 with myocardial infarction (sensitivity 60%, specificity 99%), the body surface map algorithm 137 (sensitivity 67%, specificity 89%), the physician's interpretation of the body surface map 153 (sensitivity 75%, specificity 91%) and the epicardial algorithm 158 (sensitivity 77% specificity 99%). Combining the physician's interpretation of the 12-lead ECG with the epicardial algorithm increased significantly the detection of myocardial infarction (sensitivity 85%, specificity 98%, p<0.001) compared with the 12-lead ECG. CONCLUSIONS: An epicardial algorithm based on epicardial potentials increases significantly the detection of myocardial infarction particularly among those with non-diagnostic 12-lead ECG's.

Aged↗

Efficacy of distinct energy delivery protocols comparing two biphasic defibrillators for cardiac arrest.

Limited data have been published on the use of external defibrillators that deliver impedance compensated biphasic (ICB) waveforms in patients. We compared 2 ICB defibrillators, the Heartstream XL (150-150-150 J protocol) and Heartsine Samaritan (100-150-200 J protocol) in 78 consecutive patients in cardiac arrest. The performance of the 2 devices over the first 2 shocks was statistically equivalent. By the third shock, the Heartsine Samaritan had significantly better performance in removing ventricular fibrillation (p = 0.029). Energy selection for ICB waveforms requires further validation.

Aged↗

Body surface potential mapping improves detection of ST segment alteration during percutaneous coronary intervention.

BACKGROUND: The 12-lead electrocardiogram underestimates ST segment alteration in acute coronary syndromes compared with multi-lead body surface mapping. We assessed whether 80-lead mapping would improve detection of ST alteration during percutaneous coronary intervention. METHODS: Simultaneous maps and 12-lead electrocardiograms were recorded pre-procedure, during balloon inflation and post-procedure from patients undergoing elective intervention to native coronary arteries. Recordings were obtained from 39 inflations (19 patients). All arteries were successfully stented. RESULTS: Mean 'lead specific' ST alteration (the difference in ST elevation/depression between pre-procedure and inflation recordings in the lead showing maximal ST alteration) was greater on the map than on electrocardiogram, both for ST elevation (0.16+/-0.02 vs. 0.06+/-0.01 mV; p<0.001) and ST depression (0.11+/-0.017 vs. -0.03+/-0.006 mV; p<0.001). During first inflations (n=19), mean lead specific ST elevation and depression on map were greater than on electrocardiogram (0.20+/-0.034 vs. 0.07+/-0.015 mV; p<0.001 and 0.11+/-0.029 vs. 0.03+/-0.009 mV; p=0.001, respectively). Mapping detected greater summated ST elevation and depression during inflation than electrocardiogram (0.04+/-0.005 vs. 0.021+/-0.003 mV; p<0.001 and 0.026+/-0.004 vs. 0.011+/-0.002 mV; p<0.001, respectively). Qualitative analysis of maps and electrocardiograms showed that 21/39 (53.8%) maps recorded during inflation met criteria for myocardial ischaemia compared with 7/39 (17.9%) electrocardiograms (p<0.001). CONCLUSION: Body surface mapping compared with the 12-lead electrocardiogram improves detection of myocardial ischaemia during intervention.

Angioplasty, Balloon, Coronary↗

The use of calculated epicardial potentials improves significantly the sensitivity of a diagnostic algorithm in the detection of acute myocardial infarction.

Inverse electrocardiography can calculate epicardial potentials (EP) from body surface potentials (BSP) taking into account a thoracic volume conductor model (TVCM). Previous studies have shown that a tailored TVCM is superior to a general TVCM in calculating EP. However, construction of a tailored TVCM for a patient in an acute clinical setting is impractical. In this study we used a general TVCM in our EP calculations to determine whether this improves detection of acute myocardial infarction (AMI) using a diagnostic algorithm. BSP were derived from the 80-lead body surface map (BSM). Consecutive patients (n=379) with ischemic type chest pain were recruited. The BSM and a 12-lead electrocardiogram (ECG) were recorded at initial presentation and creatine kinase (CK) and/or CK-MB were measured initially, 12 and 24 hours postsymptom onset. A physician interpreted the 12-lead electrocardiogram and documented ST elevation if present. AMI was defined by the World Health Organization (WHO) criteria. The diagnostic algorithm result for each patient using BSP and calculated EP were documented. AMI occurred in 171 patients. The diagnostic algorithm using BSP identified 106 of these as ST elevation AMI (STEMI) (sensitivity 62%, specificity 80%). The same algorithm using EP identified 133 as STEMI (sensitivity 78%, specificity 80%). Calculated EP improved the algorithm's diagnostic sensitivity by a factor of 1.25 (P<.001) with no significant difference in specificity. Calculated EP using a general TVCM significantly improves the sensitivity of a diagnostic algorithm based on BSP in detection of AMI with no significant loss in specificity.