Low nitric oxide bioavailability contributes to the genesis of experimental cerebral malaria.

The role of nitric oxide (NO) in the genesis of cerebral malaria is controversial. Most investigators propose that the unfortunate consequence of the high concentrations of NO produced to kill the parasite is the development of cerebral malaria. Here we have tested this high NO bioavailability hypothesis in the setting of experimental cerebral malaria (ECM), but find instead that low NO bioavailability contributes to the genesis of ECM. Specifically, mice deficient in vascular NO synthase showed parasitemia and mortality similar to that observed in control mice. Exogenous NO did not affect parasitemia but provided marked protection against ECM; in fact, mice treated with exogenous NO were clinically indistinguishable from uninfected mice at a stage when control infected mice were moribund. Administration of exogenous NO restored NO-mediated signaling in the brain, decreased proinflammatory biomarkers in the blood, and markedly reduced vascular leak and petechial hemorrhage into the brain. Low NO bioavailability in the vasculature during ECM was caused in part by an increase in NO-scavenging free hemoglobin in the blood, by hypoargininemia, and by low blood and erythrocyte nitrite concentrations. Exogenous NO inactivated NO-scavenging free hemoglobin in the plasma and restored nitrite to concentrations observed in uninfected mice. We therefore conclude that low rather than high NO bioavailability contributes to the genesis of ECM.

Alkenes↗

Single particle high resolution spectral analysis flow cytometry.

BACKGROUND: While conventional multiparameter flow cytometers have proven highly successful, there are several types of analytical measurements that would benefit from a more comprehensive and flexible approach to spectral analysis including, but certainly not limited to spectral deconvolution of overlapping emission spectra, fluorescence resonance energy transfer measurements, metachromic dye analysis, free versus bound dye resolution, and Raman spectroscopy. METHODS: Our system utilizes a diffraction grating to disperse the collected fluorescence and side-scattered light from cells or microspheres passing through the interrogation region over a rectangular charge-coupled-device image sensor. The flow cell and collection optics are taken from a conventional flow cytometer with minimal modifications to assure modularity of the system. RESULTS: Calibration of the prototype spectral analysis flow cytometer included wavelength characterization and calibration of the dispersive optics. Benchmarking of the system demonstrated a single particle/cell intensity sensitivity of 2160 MESF of R-Phycoerythrin. Single particle spectra taken with our instrument were validated against bulk solution fluorimeter and conventional flow cytometer measurements. Coefficients of variation of integrated spectral fluorescence intensity of several sets of standard fluorescent microspheres ranged from 1.4 to 4.8% on the spectral system. Spectral discrimination of free versus PI bound to cells is also demonstrated. CONCLUSIONS: It is demonstrated that the flow spectrometer has sufficient sensitivity and wavelength resolution to detect single cells and microspheres, including multi-fluorophore labeled microspheres. The capability to use both standard mathematical deconvolution techniques for data analysis, coupled with the feasibility of integration with existing flow cytometers, will improve the accuracy and precision of ratiometric measurements, enable the analysis of more discrete emission bands within a given wavelength range, and allow more precise resolution of the relative contribution of individual fluorophores in multiply-tagged samples, thereby enabling a range of new applications involving the spectral analysis of single cells and particles.

Calibration↗

Multiplexed and microparticle-based analyses: quantitative tools for the large-scale analysis of biological systems.

While the term flow cytometry refers to the measurement of cells, the approach of making sensitive multiparameter optical measurements in a flowing sample stream is a very general analytical approach. The past few years have seen an explosion in the application of flow cytometry technology for molecular analysis and measurements using microparticles as solid supports. While microsphere-based molecular analyses using flow cytometry date back three decades, the need for highly parallel quantitative molecular measurements that has arisen from various genomic and proteomic advances has driven the development in particle encoding technology to enable highly multiplexed assays. Multiplexed particle-based immunoassays are now common place, and new assays to study genes, protein function, and molecular assembly. Numerous efforts are underway to extend the multiplexing capabilities of microparticle-based assays through new approaches to particle encoding and analyte reporting. The impact of these developments will be seen in the basic research and clinical laboratories, as well as in drug development.

Coloring Agents↗

Microsphere-based protease assays and screening application for lethal factor and factor Xa.

BACKGROUND: Proteases regulate many biological pathways in humans and are components of several bacterial toxins. Protease studies and development of protease inhibitors do not follow a single established methodology and are mostly protease specific. METHODS: We have created recombinant fusion proteins consisting of a biotinylated attachment sequence linked to a GFP via a protease cleavage site to develop a multiplexable microsphere-based protease assay system. Using the proteases lethal factor and factor Xa, we performed kinetic experiments to determine optimal conditions for inhibitor screens and detect known inhibitors using the HyperCyt flow cytometry system. RESULTS: We have demonstrated specific cleavage of lethal factor and factor Xa substrates, optimized screening conditions for these substrates, shown specific inhibition of the proteases, and demonstrated high throughput detection of these inhibitors. CONCLUSIONS: The assay developed here is adaptable to any site-specific protease, compatible with high throughput flow cytometry systems, and multiplexable. Coupled with flow cytometry, which provides continuous time resolution and intrinsic resolution of free vs. bound fluorophores, this assay will be useful for high throughput screening of protease inhibitors in general and could simplify assays designed to determine protease mechanism.

Antigens, Bacterial↗

Multiplexed flow cytometric immunoassay for influenza virus detection and differentiation.

Microsphere-based immunoassay by flow cytometry has gained popularity lately in protein detection and infectious disease diagnosis due to its capacity for multiplexed analysis and simple assay format. Here, we demonstrated the power of microsphere-based immunoassay for high-sensitivity detection and accurate differentiation of influenza viruses. The effects of sample volume and bead number on the assay sensitivity of viral antigen detection were studied. Compared to enzyme-linked immunosorbent assays, flow-based bead assays provided approximately 10-fold lower detection limit for viral particle detection and performed similarly for recombinant viral hemagglutinin protein detection. A four-plexed assay for influenza virus typing and influenza B virus sublineage characterization was developed to demonstrate the potential for multiplexed viral antigen detection and differentiation.

Flow Cytometry↗

Cell- rather than antibody-mediated immunity leads to the development of profound thrombocytopenia during experimental Plasmodium berghei malaria.

Experimental malarial thrombocytopenia can reach life-threatening levels and is believed to be due to Abs targeting platelets for destruction by the reticuloendothelial system. However, we report that Abs account for at most 15% of platelet destruction as Plasmodium berghei-infected B cell-deficient mice exhibited profound thrombocytopenia (83%) as did C57BL/6 controls (98%). Further, no significant increase in Abs bound to intact platelets was observed during infection. P. berghei infection can enhance the activity of anti-platelet Abs as indicated by a significantly (p < 0.005) increased thrombocytopenia on day 4 of infection in mice that were administered a low dose anti-CD41 mAb compared with rat IgG1-injected controls. RAG1-/- and CD4- plus CD8-deficient mice were markedly protected from thrombocytopenia (p < 0.005) and malarial pathogenesis. CD8- or TCRgammadelta-deficient mice were not protected from thrombocytopenia and CD4-deficient mice were modestly protected. RAG1-/- mice exhibited significantly (p < 0.05) lower levels of plasma TNF, IFN-gamma, and IL-12 during infection. IFNgamma-/- and IL-12-/- mice exhibited increased survival but similar thrombocytopenia to C57BL/6 controls. Collectively, these data indicate that thrombocytopenia is necessary but not sufficient for malarial pathogenesis and Abs are not the major contributors to malarial thrombocytopenia. Rather, we propose that both CD4+ and CD8+ T cell populations play key roles in malarial thrombocytopenia; a complex bidirectional interaction between cell-mediated immunity and platelets exists during experimental severe malaria that regulates both responses.

Animals↗

Probing the kinetics of SYTOX Orange stain binding to double-stranded DNA with implications for DNA analysis.

Rapid binding kinetics of SYTOX Orange stain with double-stranded DNA (dsDNA) was revealed on the DNA fragment sizing flow cytometer. We demonstrated for the first time that the dye molecules could be adsorbed onto the capillary surface and native DNA fragments can be dynamically stained while passing through the capillary. High-quality burst size distribution histograms were obtained for DNA samples analyzed immediately after staining, dilution, or mixing. These observations indicated that rapid interactions exist between SYTOX Orange dye molecules and dsDNA. A stopped-flow fluorescence apparatus was set up to capture the fast association traces of intercalating dyes binding to dsDNA. Kinetic equations were derived to fit the association curves for determination of association rates and to model the dynamic staining, dilution, and mixing processes of DNA samples stained with intercalating dyes. The measured association rates for both SYTOX Orange and PicoGreen stains intercalating into dsDNA were on the order of 10(8) M-1 s-1, suggesting a diffusion-controlled process. Simulations indicate that reequilibration can be reached in seconds upon staining, dilution, or mixing. Insight into the kinetics of DNA binding dyes will help implement efficient sample-handling practices in DNA analysis, including DNA fragment sizing flow cytometry.

Binding Sites↗

TNF-alpha promoter polymorphisms and susceptibility to human papillomavirus 16-associated cervical cancer.

BACKGROUND: Polymorphisms in the TNF-alpha promoter region have recently been shown to be associated with susceptibility to cervical cancer. Some polymorphisms have been reported to influence transcription for this cytokine. Altered local levels in the cervix may influence an individual's immune response, thereby affecting persistence of human papillomavirus (HPV) 16 infection, a primary etiological factor for cervical cancer. METHODS AND RESULTS: The association of 11 TNF-alpha single-nucleotide polymorphisms (SNPs) with susceptibility to HPV16-associated cervical cancer was investigated. Sequencing of the TNF-alpha promoter region confirmed 10 SNPs, and 1 previously unreported SNP (161 bp upstream of the transcriptional start site) was discovered. Microsphere-array flow cytometry-based genotyping was performed on 787 samples from Hispanic and non-Hispanic white women (241 from randomly selected control subjects, 205 from HPV16-positive control subjects, and 341 from HPV16-positive subjects with cervical cancer). The genotype distribution of 3 SNPs (-572, -857, and -863) was significantly different between case subjects and control subjects. Analysis of haplotypes, which were computationally inferred from genotype data, also revealed statistically significant differences in haplotype distribution between case subjects and control subjects. CONCLUSIONS: We report new associations between several TNF-alpha SNPs and susceptibility to cervical cancer that support the involvement of the TNF- alpha promoter region in development of cervical cancer.

Adolescent↗

Direct fluorescent staining and analysis of proteins on microspheres using CBQCA.

BACKGROUND: General methods for accurate determination of microsphere surface protein loading are needed for applications from protein arrays to molecular assembly studies. Current methods include bulk absorption measurements of stained microspheres or use of known fluorescently tagged binding partners, which limit sensitivity and general applicability, respectively. METHODS: Microspheres bearing covalently coupled proteins were stained with 3-(4-carboxybenzoyl)quinoline-2-carboxaldehyde (CBQCA) using different incubation times and dye concentrations to determine optimal staining conditions. The CBQCA fluorescence of microspheres (measured by flow cytometry) bearing known amounts of protein were used to generate standard curves of CBQCA fluorescence response versus the amount of microsphere surface protein. CBQCA was also used to stain noncovalent protein interactions. RESULTS: Maximal labeling was attained within 1 h with 1 mM CBQCA. Linear fluorescence response occurred between 8 x 10(4) and 1 x 10(6) proteins/microsphere. CBQCA staining did not disturb noncovalent protein interactions. CONCLUSIONS: We have developed methods using CBQCA and flow cytometry to quickly and simply quantify the amount of protein on the surface of a microsphere. Importantly, this approach could be extended to other formats (e.g., chips). Further, because it does not disturb noncovalent protein-protein interactions, it may be possible to use this approach to detect protein interactions without the use of purified prestained probes.

Animals↗

Microsphere-based duplexed immunoassay for influenza virus typing by flow cytometry.

We have developed a rapid, duplexed microsphere-based immunoassay for the characterization of influenza virus types that has the potential to overcome many of the limitations of current detection methods. The assay uses microspheres of two sizes, each coupled to an influenza type A- or type B-specific monoclonal antibody (MAb), to capture influenza viruses in the sample. A cocktail of fluorescently labeled, influenza-specific polyclonal antibodies then binds the captured viruses. The sandwich complexes are measured using a multiparameter flow cytometer. The assay can distinguish between influenza types A and B in a single reaction with good reproducibility and high sensitivity. Detection sensitivity is much higher than that of commercially available influenza diagnosis quick kits: the FLU OIA (Thermo Biostar) kit and the Directigen Flu A+B kit (Becton Dickinson). The multiplexing capabilities of the current assay, which are not possible with enzyme-linked immunosorbent assay (ELISA) and the commercially available kits, reduce sample handling and consume fewer costly reagents. This assay represents a more efficient and sensitive method of characterizing influenza types. With inclusion of influenza subtype-specific antibodies as capture antibodies, this microsphere-based immunoassay can be expanded to differentiate among influenza types and subtypes in a single reaction to improve world-wide influenza surveillance.

Antibodies, Monoclonal↗

Development of rationally designed nucleic acid signatures for microbial pathogens.

The detection and identification of microbial pathogens are critical challenges in clinical medicine and public health surveillance. Advances in genome analysis technology are providing an unprecedented amount of information about bacterial and viral organisms, and hold great potential for pathogen detection and identification. In this paper, a rational approach to the development and application of nucleic acid signatures is described based on phylogenetically informative sequence features, especially single nucleotide polymorphisms. The computational tools that are available to enable the development of the next generation of microbial molecular signatures for clinical diagnostics and infectious disease surveillance are reviewed and the impact on public health and national security will be discussed.

Bacteria↗

A simple quenching method for fluorescence background reduction and its application to the direct, quantitative detection of specific mRNA.

New genome sequence information is rapidly increasing the number of nucleic acid (NA) targets of use for characterizing and treating diseases. Detection of these targets by fluorescence-based assays is often limited by fluorescence background from unincorporated or unbound probes that are present in large excess over the target. To solve this problem, energy transfer-based probes have been developed and used to reduce the fluorescence from unbound probes. Although these probes have revolutionized NA target detection, their use requires scrupulous attention to design constraints, extensive probe quality control, and individually optimized experimental conditions. Here, we describe a simpler background reduction approach using singly labeled quencher oligomers to suppress excess unbound probe fluorescence following probe-target hybridization. A second limitation of most fluorescence-based NA target detection and quantification assays is the requirement for enzymatic amplification of target or signal for sensitivity. Amplification steps make quantification of original target copy number problematic because of variations in amplification efficiencies between the sequence targets and the experimental conditions. To avoid amplification, we coupled our quenching approach to a two-color NA assay with correlated, two-color, single-molecule fluorescence detection. We demonstrate a >100-fold background reduction and detection of targets present at concentrations as low as 100 fM using the two-color assay. The application of this technique to the detection and quantification of specific mRNA sequences enabled us to estimate beta-actin copy numbers in cell-derived total RNA without an amplification step.

Actins↗

Primer-design for multiplexed genotyping.

Single-nucleotide polymorphism (SNP) analysis is a powerful tool for mapping and diagnosing disease-related alleles. Mutation analysis by polymerase-mediated single-base primer extension (minisequencing) can be massively parallelized using DNA microchips or flow cytometry with microspheres as solid support. By adding a unique oligonucleotide tag to the 5' end of the minisequencing primer and attaching the complementary antitag to the array or bead surface, the assay can be 'demultiplexed'. Such high-throughput scoring of SNPs requires a high level of primer multiplexing in order to analyze multiple loci in one assay, thus enabling inexpensive and fast polymorphism scoring. We present a computer program to automate the design process for the assay. Oligonucleotide primers for the reaction are automatically selected by the software, a unique DNA tag/antitag system is generated, and the pairing of primers and DNA tags is automatically done in a way to avoid any crossreactivity. We report results on a 45-plex genotyping assay, indicating that minisequencing can be adapted to be a powerful tool for high-throughput, massively parallel genotyping. The software is available to academic users on request.

Algorithms↗

Development and characterization of Ni-NTA-bearing microspheres.

BACKGROUND: For ease of purification, proteins are often expressed with a short affinity sequence of five or six adjacent histidine residues (His-tag). This His-tag binds to the metal of metal chelator complexes such as Ni(2+)-nitrilotriacetic acid (Ni-NTA) or -iminodiacetic acid (Ni-IDA). Chromatography resins bearing covalently attached metal chelator complexes are used widely for the easy affinity purification of His-tagged proteins or peptides. Because Ni-NTA microspheres were not commercially available at the beginning of our studies, we prepared and characterized such microspheres to immobilize His-tagged proteins and study their interactions. Our microspheres are of three types: (a) metal chelator complexes bound covalently to polystyrene microspheres, (b) metal chelator complexes bound covalently to silica microspheres, and (c) lipid-linked metal chelator complexes adsorbed to silica microspheres forming self-assembled bilayer membranes where the metal chelators have lateral mobility. METHODS: The microspheres bearing covalently attached Ni-chelator were synthesized by reacting a primary amine-bearing Ni-NTA ligand with carboxy-functionalized microspheres and then loading with Ni(2+). Microspheres with laterally mobile metal chelator were made by incubating glass microspheres with liposomes containing phosphatidylcholine (PC) and the metal chelating lipid 1,2-dioleoyl-sn-glycero-3-[(N (5-amino-1-carboxypentyl)iminodiacetic acid)succinyl]. Binding of a His-tagged enhanced green fluorescent protein (EGFP) was used to characterize these microspheres by flow cytometry for their specificity, sensitivity, capacity and stability. RESULTS: While all micospheres specifically bind His-tagged proteins, the conditions to achieve this are different for the polystyrene- and silica-based spheres. All three types of microspheres bind His-EGFP with saturation occurring at 30-50 nM and an apparent avidity (concentration of half-maximal binding) of approximately 1 to 2 x 10(-8) M at pH 7.4. Binding of His-EGFP is inhibited by imidazole or ethylene-diaminetetraacetic acid (EDTA). Polystyrene Ni-NTA microspheres showed significant nonspecific binding as measured by binding in the presence of imidazole or EDTA or by binding of fluorescent proteins lacking a His-tag. This nonspecific binding of proteins to and aggregation of polystyrene spheres could only be prevented by the inclusion of low concentrations of Tween 20, but not by including bovine serum albumin (BSA), polyethylene glycols, or polyvinylpyrrolidones as blocking agents. In contrast, silica-based microspheres with covalently attached Ni-NTA or silica microspheres bearing adsorbed bilayers that contain Ni-NTA-lipid showed little nonspecific binding in the presence of BSA. Our results on the stability of immobilization indicate that washing destabilizes the binding of His-tagged proteins to Ni-NTA microspheres. This binding consists of two interactions of different affinities. We also demonstrate that limited multiplexed analysis with differently sized silica microspheres bearing the Ni-NTA-lipid is feasible. CONCLUSIONS: The microspheres described are well suited to selectively immobilize His-tagged proteins to analyze their interactions by flow cytometry. The affinity and kinetic stability of the interaction of His-tagged proteins with Ni-NTA are insufficient to use Ni-NTA microspheres in multiplexed analysis formats where different His-tagged proteins are bound to distinct microspheres. Improvements towards this end (improved chelators and/or improved affinity tags) are critical for extending the use of this method. We are currently working on novel chelators to strengthen the stability of immobilization of His-tagged proteins to surfaces. Such improvements would greatly enhance the analysis of interactions of immobilized His-tagged proteins and could make the development of microsphere-based arrays with His-tagged protein/antibody possible.

Binding Sites↗

Analysis of cholera toxin-ganglioside interactions by flow cytometry.

Cholera toxin entry into mammalian cells is mediated by binding of the pentameric B subunit (CTB) to ganglioside GM(1) in the cell membrane. We used flow cytometry to quantitatively measure in real time the interactions of fluorescently labeled pentameric cholera toxin B-subunit (FITC-CTB) with its ganglioside receptor on microsphere-supported phospholipid membranes. A model that describes the multiple steps of this mode of recognition was developed to guide our flow cytometric experiments and extract relevant equilibrium and kinetic rate constants. In contrast to previous studies, our approach takes into account receptor cross-linking, an important feature for multivalent interactions. From equilibrium measurements, we determined an equilibrium binding constant for a single subunit of FITC-CTB binding monovalently to GM(1) presented in bilayers of approximately 8 x 10(7) M(-1) while that for binding to soluble GM(1)-pentasaccharide was found to be approximately 4 x 10(6) M(-1). From kinetic measurements, we determined the rate constant for dissociation of a single site of FITC-CTB from microsphere-supported bilayers to be (3.21 +/- 0.03) x 10(-3) s(-1), and the rate of association of a site on FITC-CTB in solution to a GM(1) in the bilayer to be (2.8 +/- 0.4) x 10(4) M(-1) s(-1). These values yield a lower estimate for the equilibrium binding constant of approximately 1 x 10(7) M(-1). We determined the equilibrium surface cross-linking constant [(1.1 +/- 0.1) x 10(-12) cm(2)] and from this value and the value for the rate constant for dissociation derived a value of approximately 3.5 x 10(-15) cm(2) s(-1) for the forward rate constant for cross-linking. We also compared the interaction of the receptor binding B-subunit with that of the whole toxin (A- and B-subunits). Our results show that the whole toxin binds with approximately 100-fold higher avidity than the pentameric B-subunit alone which is most likely due to the additional interaction of the A(2)-subunit with the membrane surface. Interaction of cholera toxin B-subunit and whole cholera toxin with gangliosides other than GM(1) revealed specific binding only to GD1(b) and asialo-GM(1). These interactions, however, are marked by low avidity and require high receptor concentrations to be observed.

Animals↗

Nozzle design parameters and their effects on rapid sample delivery in flow cytometry.

BACKGROUND: Rapid kinetic and high throughput flow cytometry are emerging as valuable tools in biotechnology research applications ranging from mechanistic analysis of molecular assemblies to high throughput screening. Many of these new applications have been made possible by improved sample delivery capabilities, focusing increased attention on fluidic issues associated with rapid sample delivery. METHODS: Using basic fluidic premises, we derived a model that predicted the effect of nozzle parameters during rapid sample delivery. We tested the model using the rapid mix flow cytometer and modifications were made to the equipment to optimize performance. RESULTS: The model predicted that shorter nozzles with wide exit orifices decrease the delay before initial particle analysis and the fluidic stabilization time. Experimental results confirmed this prediction and model-based modifications allowed analysis of particles within 55 ms or 600 ms after mixing, with or without electronic gating, respectively. CONCLUSIONS: The model along with modifications to commercial equipment will allow rapid mix flow cytometry to analyze reactions in time frames threefold shorter than previously possible. The model allows for nozzle design predictions that should allow for analysis in the millisecond time frame. Furthermore, these findings are general for all rapid delivery applications, including high throughput flow cytometry.

Automation↗

Suspension array technology: evolution of the flat-array paradigm.

Suspension arrays of microspheres analyzed using flow cytometry offer a new approach to multiplexed assays for large-scale screening applications. By optically encoding micron-sized polymer particles, suspension microarrays can be created to enable highly multiplexed analysis of complex samples. Each element in the array is comprised of a subpopulation of particles with distinct optical properties and each array element bears a different surface receptor. Nucleic acids, proteins, lipids or carbohydrates can serve as receptors to support the analysis of a wide range of biomolecular assemblies, and applications in genomic and proteomic research are being developed. Coupled with recent innovations for rapid serial analysis of samples, molecular analysis with microsphere arrays holds significant potential as a general analysis platform for both research and clinical applications.

Directed Molecular Evolution↗

Flow cytometric analysis of ligand-receptor interactions and molecular assemblies.

Flow cytometers make homogeneous real-time measurements of ligand-receptor interactions and, simultaneously, the physiological responses of cells. Their multiparameter capabilities are also useful in resolving multicomponent assemblies or in developing multiplexed assays. Recent advances suggest that these approaches can be extended in several important ways. Sample delivery in the millisecond time domain is applicable to the analysis of complex binding kinetics and reaction mechanisms. The homogeneous discrimination of free components and particle-based assemblies can be extended into the micromolar concentration range. Measurements can be made of molecular assemblies among proteins, DNA, RNA, lipids, and carbohydrates on beads. The topography and assembly of components within cells can be evaluated with resonance energy transfer. Temperature dependence can be evaluated with Peltier temperature control. Many assembly endpoints can be assessed through new tools for high-throughput flow cytometry using plate-based assay formats and small volume samples.

Animals↗