PubMed Health⌕ Search

Biomedical subjects

John R Ives

Publications and source records attributed to John R Ives.

11 recordsLinked to original sources

Improving functional magnetic resonance imaging motor studies through simultaneous electromyography recordings.

Specially designed optoelectronic and data postprocessing methods are described that permit electromyography (EMG) of muscle activity simultaneous with functional MRI (fMRI). Hardware characterization and validation included simultaneous EMG and event-related fMRI in 17 healthy participants during either ankle (n = 12), index finger (n = 3), or wrist (n = 2) contractions cued by visual stimuli. Principal component analysis (PCA) and independent component analysis (ICA) were evaluated for their ability to remove residual fMRI gradient-induced signal contamination in EMG data. Contractions of ankle tibialis anterior and index finger abductor were clearly distinguishable, although observing contractions from the wrist flexors proved more challenging. To demonstrate the potential utility of simultaneous EMG and fMRI, data from the ankle experiments were analyzed using two approaches: 1) assuming contractions coincided precisely with visual cues, and 2) using EMG to time the onset and offset of muscle contraction precisely for each participant. Both methods produced complementary activation maps, although the EMG-guided approach recovered more active brain voxels and revealed activity better in the basal ganglia and cerebellum. Furthermore, numerical simulations confirmed that precise knowledge of behavioral responses, such as those provided by EMG, are much more important for event-related experimental designs compared to block designs. This simultaneous EMG and fMRI methodology has important applications where the amplitude or timing of motor output is impaired, such as after stroke.

Adult↗

Electroencephalographic recording during transcranial magnetic stimulation in humans and animals.

OBJECTIVE: We report on the development of an EEG recording system, comprised of electrodes and amplifiers that are compatible with TMS (single and rapid-rate) in both human and animal studies. METHODS: We assembled a versatile multi-channel EEG recording system consisting of: (1) two types of electrodes that are safe during TMS or rTMS. (2) Low slew-rate EEG amplifiers that recover within a few milliseconds after the application of TMS pulses. RESULTS: The two electrode types: (a) a conductive-plastic surface electrode with a conductive-silver epoxy coat and (b) a subdermal silver wire electrode (SWE) are compatible to TMS pulses. The amplifiers recover within 30 ms, so that the EEG can be viewed online, essentially without interruption and/or blocking or excessive artifact. CONCLUSIONS: Our TMS compatible electrode and EEG recording system allows safe and online viewing/recording of the subject's (human or animal) EEG/EP during experiments or studies involving TMS or rTMS applications. The TMS compatible electrode/amplifier system can be used with any EEG recording instrument. SIGNIFICANCE: A simple recording technique coupled with new electrodes permit safe and readable EEG records during TMS in humans and animals. Such online monitoring of the EEG would allow control of TMS/rTMS parameters based on EEG activity.

Animals↗

A comparison of subdermal wire electrodes with collodion-applied disk electrodes in long-term EEG recordings in ICU.

OBJECTIVE: To compare long-term electroencephalographic (EEG) recordings of standard collodion-applied scalp disk electrodes (SDEs) with newly developed subdermal wire electrodes (SWEs) in comatose intensive care unit (ICU) patients. METHODS: Ten comatose ICU patients had simultaneous recordings from 8 active SDEs and 8 active SWE for >24 h. The timing and number of 60 Hz and other electrode artifacts were compared for each set of electrodes by an EEGer who read the recordings in a blinded manner. RESULTS: Sixty Hertz artifact was seen in 16 of 80 SDE and one of 80 SWEs within the first 6 h (P=0.0002). Large, persistent artifacts occurred in 30/80 SDE and 8 of 80 SWE (P=0.0001). Motion artifact with chest physiotherapy was more common in SWEs. CONCLUSIONS: SWE are less susceptible to artifacts and are more suitable for the long-term EEG monitoring in ICU. SIGNIFICANCE: This is the first controlled study that demonstrates the superiority of SWEs compared to SDEs in an ICU population.

Adolescent↗

Linear aspects of transformation from interictal epileptic discharges to BOLD fMRI signals in an animal model of occipital epilepsy.

Epileptic disorders manifest with seizures and interictal epileptic discharges (IEDs). The hemodynamic changes that accompany IEDs are poorly understood and may be critical for understanding epileptogenesis. Despite a known linear coupling of the neurovascular elements in normal brain tissues, previous simultaneous electroencephalography (EEG)-functional magnetic resonance imaging (fMRI) studies have shown variable correlations between epileptic discharges and blood oxygenation level-dependent (BOLD) response, partly because most previous studies assumed particular hemodynamic properties in normal brain tissue. The occurrence of IEDs in human subjects is unpredictable. Therefore, an animal model with reproducible stereotyped IEDs was developed by the focal injection of penicillin into the right occipital cortex of rats anesthetized with isoflurane. Simultaneous EEG-fMRI was used to study the hemodynamic changes during IEDs. A hybrid of temporal independent component analysis (ICA) of EEG and spatial ICA of fMRI data was used to correlate BOLD fMRI signals with IEDs. A linear autoregression with exogenous input (ARX) model was used to estimate the hemodynamic impulse response function (HIRF) based on the data from simultaneous EEG-fMRI measurement. Changes in the measured BOLD signal from the right primary visual cortex and bilateral visual association cortices were consistently coupled to IEDs. The linear ARX model was applied here to confirm that a linear transform can be used to study the correlation between BOLD signal and its corresponding neural activity in this animal model of occipital epilepsy.

Animals↗

A new device and protocol for combining TMS and online recordings of EEG and evoked potentials.

We describe an electroencephalographic (EEG) device and protocol that allows recording of electrophysiological signals generated by the human brain during transcranial magnetic stimulation (TMS) despite the TMS-induced high-voltage artifacts. The key hardware components include slew-rate limited preamplifiers to prevent saturation of the EEG system due to TMS. The protocol involves artifact subtraction to isolate the electrophysiological signals from residual TMS-induced contaminations. The TMS compatibility of the protocol is illustrated with examples of two data sets demonstrating the feasibility of the approach in the single-pulse TMS design, as well as during repetitive TMS. Our data show that both high-amplitude potentials evoked by visual checkerboard stimulation and low-amplitude steady-state oscillations induced by auditory click-trains can be retrieved with the present protocol. The signals recorded during TMS perfectly matched control EEG responses to the same visual and auditory stimuli. The main field of application of the present protocol is in cognitive neuroscience complementing behavioral studies that use TMS to induce transient, 'virtual lesions'. Combined EEG-TMS techniques provide neuroscientists with a unique method to test hypothesis on functional connectivity, as well as on mechanisms of functional orchestration, reorganization, and plasticity.

Adult↗

Physiological monitoring of small animals during magnetic resonance imaging.

Maintaining a stable physiologic state is essential when studying animal models of epilepsy with simultaneous electroencephalograph (EEG) and functional magnetic resonance imaging (fMRI) or EEG and magnetic resonance spectroscopy (MRS). To achieve and maintain such stability in rats in the MRI environment, a minimally invasive but comprehensive system was developed to monitor body temperature, heart rate, blood pressure, blood oxygen saturation and end-tidal CO2 (ETCO2) of expired gas. All physiologic parameters were successfully monitored in Sprague-Dawley rats without interfering with EEG recordings during simultaneous fMRI and MRS studies. Body temperature, heart rate, blood pressure, blood oxygen saturation, and ETCO2, were maintained between 36.5 and 37.5 degrees C, 250-450 beats/min, 136+/-17 mmHg, >90%, and 20-35 mmHg, respectively for 6-8 h under inhalational anesthesia. This set-up could be extended to study in vivo applications in other laboratory animals with only minor modifications.

Anesthetics, Inhalation↗

Real-time display of artifact-free electroencephalography during functional magnetic resonance imaging and magnetic resonance spectroscopy in an animal model of epilepsy.

Simultaneous recording of electroencephalogram (EEG) and functional MRI (fMRI) or MR spectroscopy (MRS) can provide further insight into our understanding of the underlying mechanisms of neurologic disorders. Current technology for simultaneous EEG and MRI recording is limited by extensive postacquisition processing of the data. Real-time display of artifact-free EEG recording during fMRI/MRS studies is essential in studies that involve epilepsy to ensure that they address specific EEG features such as epileptic spikes or seizures. By optimizing the EEG recording equipment to maximize the common mode rejection ratio of its amplifiers, a unique EEG system was designed and tested that allowed real-time display of the artifact-free EEG during fMRI/MRS in an animal model of epilepsy. Spike recordings were optimized by suppression of the background EEG activity using fast-acting and easily controlled inhalational anesthesia. Artifact suppression efficiency of 70-100% was achieved following direct subtraction of referentially recorded filtered EEG tracings from active electrodes, which were located in close proximity to each other (over homologous occipital cortices) and a reference electrode. Two independent postacquisition processing tools, independent component analysis and direct subtraction of unfiltered digital EEG data in MATLAB, were used to verify the accuracy of real-time EEG display.

Algorithms↗

New chronic EEG electrode for critical/intensive care unit monitoring.

The main limiting factor of EEG monitoring in the critical/intensive care environments is, and always has been, the recording electrode. The electrode and its application to the scalp has changed very little since EEG was first discovered and developed as a clinical tool. However, the evolution of amplifiers and data acquisition systems have made tremendous strides. Modern-day EEG recording systems now have the capability to record for days and weeks with little intervention, whereas the EEG electrode requires constant attention and skilled adjustment every 10 to 24 hours. If one surveys the vast array of electrodes used now and in the past, the only electrode that, once placed, never needed any further adjustment for days and weeks on end, was the chronic silver-silver/chloride (Ag-Ag/Cl) sphenoidal (Sp) electrode. This Sp electrode has now been modified to permit it to be placed subdermally, similar to that of a subdermal needle electrode, but now the needle is removed to leave in place a fine, flexible, durable, chronic Ag-Ag/Cl electrode. Once placed, this subdermal wire electrode (SWE, patent pending) starts to record immediately with a low impedance of 3 to 4 Komega. This electrode can record any biopotential, in humans and in animals, and in most recording environments; it never needs adjustment, and records high-quality biopotential signals for as long as it is left in place. The SWE is also MRI and computed-tomography compatible. It takes less than half the time to place the SWE, and placement can now be performed by any medically trained personnel to obtain a low-maintenance, high-quality EEG recording.

Critical Care↗

MRI compatible EEG electrode system for routine use in the epilepsy monitoring unit and intensive care unit.

OBJECTIVE: We report on the development of an electroencephalographic (EEG) recording system that is Magnetic Resonance Imaging (MRI) compatible and can safely be left on the scalp during anatomical imaging or used to obtain simultaneous EEG and metabolic or hemodynamic data using functional imaging techniques such as functional MRI or MR spectroscopy. METHODS: We assembled a versatile EEG recording set-up with medically acceptable materials that contained no ferromagnetic components. It was tested for absence of excess heating and distortion of the image quality in a spherical phantom similar in size to average adult human head in a clinical 1.5 T GE scanner. After testing its safety in four volunteers, 100 consecutive patients from our epilepsy long-term monitoring unit were studied. RESULTS: There was no change in the temperature of the EEG electrode discs during the various anatomical MRI sequences used in our routine clinical studies (maximum temperature change was -0.45 degrees C with average head SAR<==1.6 W/Kg in the selected subjects) nor were there any reported complications in the others. The brain images were not distorted by the susceptibility artifact of the EEG electrodes. CONCLUSIONS: Our MRI compatible EEG set-up allows safe and artifact free brain imaging in 1.5T MR scanner with average SAR<==1.6 W/Kg. This EEG system can be used for EEG recording during anatomical MRI studies as well as functional imaging studies in patients requiring continuous EEG recordings.

Artifacts↗

Outpatient EEG monitoring in the presurgical evaluation of patients with refractory temporal lobe epilepsy.

Most epilepsy centers obtain ictal EEG recordings to localize the epileptogenic zone during presurgical evaluations. Inpatient monitoring is standard practice but is expensive and can be inconvenient. The authors sought to determine whether outpatient monitoring can be safe and effective as the sole method of recording seizures in the presurgical evaluation of patients with refractory temporal lobe epilepsy. They reviewed the data of seven temporal lobectomy patients whose presurgical monitoring was performed entirely outside the hospital. Mean baseline seizure frequency was at least 9.1 seizures per week. An average of 7.4 seizures was recorded over 9.4 days of monitoring. Only one patient had any antiepileptic drug taper; none suffered any complications. After temporal lobectomy on the side of demonstrated ictal onset, postoperative follow-up averaged 5.5 years. At the most recent follow-up, all patients were either seizure free or had only rare disabling or nocturnal seizures (four patients had outcomes in Engel's class I and three patients in Engel's class II). A comparison group who underwent standard inpatient monitoring was similar in average seizure frequency, monitoring duration, number of seizures recorded, and postoperative outcome, although all but one had antiepileptic drugs tapered during monitoring. The authors conclude that there is a subset of patients for whom solely outpatient presurgical EEG monitoring can be used to help plan successful temporal lobectomy.

Adult↗