PubMed Health⌕ Search

Biomedical subjects

John Shultz

Publications and source records attributed to John Shultz.

3 recordsLinked to original sources

A bioluminescent assay for monoamine oxidase activity.

This article describes a novel two-step homogeneous bioluminescent assay for monoamine oxidase (MAO) that is simple, sensitive, and amenable to high-throughput screening. In the first step, MAO reacts with an aminopropylether analog of methyl ester luciferin. In the second step, a luciferin detection reagent inactivates MAO and converts the product of the first step into a luminescent signal. The amount of light produced is proportional to the amount of MAO and the time of incubation in the first step, but the luminescent signal is stable in the second step with a half-life greater than 5h. The assay has high precision, is more sensitive than current fluorescent methods, and can accurately measure the binding constants of known substrates and inhibitors. An automated screen of the Sigma-RBI Library of Pharmacologically Active Compounds (LOPAC(1280)) revealed a surprisingly high percentage of MAO inhibitors (16%) with a low false hit rate (0.9%). This implies that a significant number of compounds interact with the MAO enzymes and suggests that it is important to include MAO assays in drug metabolism studies. Other advantages of this bioluminescent assay over comparable fluorescent assays are discussed.

Animals↗

New bioluminogenic substrates for monoamine oxidase assays.

Novel bioluminogenic substrates were designed for probing monoamine oxidase (MAO) activity based on a simple and effective beta-elimination strategy. By modifying the amino group and the central core of luciferin derivatives, we have developed a series of substrates useful for assays of MAO A or B, or both. One of these substrates, exhibiting low Km values and high signal-to-background ratios with both isozymes, was shown to accurately measure the Ki values of known MAO inhibitors. This substrate is a key component in the development of a highly sensitive homogeneous MAO assay for high-throughput screening (HTS) of compounds in drug discovery and for monitoring MAO activity in complex biological systems. This design strategy should be applicable to fluorogenic MAO substrates and could broaden the structural requirements of substrates for other enzyme assays.

Firefly Luciferin↗

Small-scale telomere repeat sequence content assay using pyrophosphorolysis coupled with ATP detection.

Studies of telomere length have been carried out in diverse areas of research. However, current methods to measure telomeres are cumbersome and not amenable to high-throughput analyses. Using a coupled pyrophosphorolysis/trans-phosphorylation reaction, we have developed a novel assay to quantitate telomere sequence content in a single tube or 96-well format. The method uses a telomere-specific oligonucleotide probe to sample nanogram quantities of DNA without PCR amplification. Polymerase and kinase enzymes drive the production of ATP, which is then monitored with a luciferase enzyme reporter system. Using this approach, we demonstrated that the luminescent output was linear across a 100-fold range of DNA input, and the assay was sensitive to 0.4-1 ng DNA. A control probe reaction and a DNA quantitation reaction were also designed using the same pyrophosphorolysis technology to correct for background activity and normalize the signal against variations in DNA input, respectively. Finally, we show that the normalized luminescent signal generated by this new method is highly correlated to the telomere restriction fragment length for six human cell lines.

Adenosine Triphosphate↗