PubMed Health⌕ Search

Biomedical subjects

John W Pyhtila

Publications and source records attributed to John W Pyhtila.

5 recordsLinked to original sources

Fourier-domain angle-resolved low coherence interferometry through an endoscopic fiber bundle for light-scattering spectroscopy.

We present a novel endoscopic fiber bundle probe incorporated in a Fourier-domain angle-resolved low coherence interferometry system for the measurement of depth-resolved angular scattering distributions to permit the determination of scatterer size via elastic scattering properties. Depth resolution is achieved with a superluminescent diode via a Mach-Zehnder interferometer. The sample is illuminated with a collimated beam, and a Fourier plane image of the backscattered light is collected by a coherent fiber bundle. The angular scattering distribution relayed by the fiber bundle is mixed with the reference field and made to coincide with the input slit of an imaging spectrograph. The data collected are processed in real time, producing a depth-resolved angular scattering distribution in 0.37 s. The data are used to determine the sizes of polystyrene microspheres with subwavelength precision and accuracy.

Endoscopes↗

Improved interferometric detection of scattered light with a 4f imaging system.

We analyze the performance of three imaging systems to detect near-forward scattered light interferometrically by using a Mach-Zehnder geometry. The alignment of each system is demonstrated by measurement of the heterodyne efficiency and correlation of the angular width and field 1/e radius measurements of the sample beam. Measurements of angular-scattering data demonstrate the range of angles over which each system is effective. Of the three systems analyzed, the 4f imaging system is determined to be most effective, because it accurately reproduces both the phase and the amplitude of the scattered field at the detector.

Equipment Design↗

Rapid, depth-resolved light scattering measurements using Fourier domain, angle-resolved low coherence interferometry.

We present a novel angle-resolved low coherence interferometry scheme for rapid measurement of depth-resolved angular scattering distributions to enable determination of scatterer size via elastic scattering properties. Depth resolution is achieved using a superluminescent diode in a modified Mach-Zehnder interferometer with the mixed signal and reference fields dispersed by an imaging spectrograph. The spectrograph slit is located in a Fourier transform plane of the scattering sample, enabling angle-resolved measurements over a 0.21 radian range. The capabilities of the new technique are demonstrated by recording the distribution of light scattered by a sub-surface layer of polystyrene microspheres in 40 milliseconds. The data are used to determine the microsphere size with good accuracy. Future clinical application to measuring the size of cell nuclei in living epithelial tissues using backscattered light is discussed.

Journal Article↗

Prospective grading of neoplastic change in rat esophagus epithelium using angle-resolved low-coherence interferometry.

Angle-resolved low-coherence interferometry (a/LCI) is used to obtain quantitative, depth-resolved nuclear morphology measurements. We compare the average diameter and texture of cell nuclei in rat esophagus epithelial tissue to grading criteria established in a previous a/LCI study to prospectively grade neoplastic progression. We exploit the depth resolution of a/LCI to exclusively examine the basal layer of the epithelium, approximately 50 to 100 microm beneath the tissue surface, without the need for exogenous contrast agents, tissue sectioning, or fixation. The results of two studies are presented that compare the performance of two a/LCI modalities. Overall, the combined studies show 91% sensitivity and 97% specificity for detecting dysplasia, using histopathology as the standard. In addition, the studies enable the effects of dietary chemopreventive agents, difluoromethylornithine (DFMO) and curcumin, to be assessed by observing modulation in the incidence of neoplastic change. We demonstrate that a/LCI is highly effective for monitoring neoplastic change and can be applied to assessing the efficacy of chemopreventive agents in the rat esophagus.

Animals↗

Analysis of long range correlations due to coherent light scattering from in-vitro cell arrays using angle-resolved low coherence interferometry.

Angle-resolved low coherence interferometry (a/LCI) enables depth-resolved measurements of scattered light that can be used to recover subsurface structural information, such as the size of cell nuclei. Measurements of nuclear morphology, however, can be complicated by coherent scattering between adjacent cell nuclei. Previous studies have eliminated this component by applying a window filter to Fourier transformed angular data, based on the justification that the coherent scattering must necessarily occur over length scales greater than the cell size. To fully study this effect, results of experiments designed to test the validity of this approach are now presented. The a/LCI technique is used to examine light scattered by regular cell arrays, created using stamped adhesive micropatterned substrates. By varying the array spacing, it is demonstrated that cell-to-cell correlations have a predictable effect on light scattering distributions. These results are compared to image analysis of fluorescence micrographs of the cell array samples. The a/LCI results show that the impact of coherent scattering on nuclear morphology measurements can be eliminated through data filtering.

Algorithms↗