PubMed Health⌕ Search

Biomedical subjects

Jonas Bergquist

Publications and source records attributed to Jonas Bergquist.

At least 19 recordsLinked to original sources

Lipid synthesis seems to drive proliferation in Men1 mouse adrenals and human adrenocortical cell lines.

Adrenocortical carcinoma (ACC) is a devastating disease with few effective treatments. The underlying molecular pathways remain largely unknown. To identify potential pathways and drivers relevant to ACC pathogenesis, we utilized histologically normal adrenals from heterozygous multiple endocrine neoplasia type 1 (Men1) mice to study early adrenocortical tumorigenesis. Employing mass spectrometry-based proteomic profiling, we identified 681 proteins, of which 52 displayed significant differential regulation in the adrenal tissues of heterozygous Men1 mice in comparison with their wild-type counterparts. Among these were fatty acid synthase (FASN) and ATP-citrate lyase (ACLY), two enzymes previously shown to be upregulated in several other types of tumors. To assess the functional impact of ACLY and FASN in ACC, we used H295R cells as the primary model. Cells were treated with SB-204990 (ACLY inhibitor) or C75 (FASN inhibitor), which both showed a dose-dependent antiproliferative effect. Lipidomic analysis revealed a significant reduction in palmitic acid and palmitoleic acid in treated cells compared to controls, supporting a mechanistic link between ACLY/FASN activity and lipid biosynthesis. Finally, data from The Cancer Genome Atlas showed significantly diminished survival outcomes among ACC patients exhibiting high ACLY or FASN expression. These findings underscore the potential importance of exploring the inhibition of lipid synthesis as a promising avenue for further research in the context of human ACC.

Animals↗

Comparison of Proteomic Analysis of Cerebrospinal Fluid From Neurological Patients With and Without Amyotrophic Lateral Sclerosis.

Amyotrophic lateral sclerosis (ALS) is a neurodegenerative disorder characterised by progressive muscle weakness in both bulbar and extremity muscles, leading to a diverse clinical phenotype with motor and non-motor symptoms. Approximately 85% of ALS cases are sporadic (sALS), while the remaining 10%-15% are familial (fALS). Biological biomarkers of sporadic ALS remain poorly understood, hindering precise patient screening, delaying diagnosis and negatively affecting prognosis. This study aims to identify potential proteomic biomarkers by comparing the cerebrospinal fluid (CSF) of sALS patients with that of patients suffering from other neurological diseases. Liquid chromatography-tandem mass spectrometry (LC-MS/MS) was used for proteomic profiling of CSF samples from 24 sALS patients and 26 patients with other neurological diseases. The complete protein expression profiles were compared using a two-tailed Student's t-test, with a p <&#x2009;0.05 considered statistically significant with additional FDR correction at the 0.1 level. Proteomic analysis of CSF samples identified significant quantitative changes in 96 proteins with threshold p&#x2009;<&#x2009;0.05 and 74 proteins with FDR <&#x2009;0.1 between sALS and non-ALS patients, including alterations in proteins associated with neurodegenerative processes, such as amyloid precursor proteins and inflammatory markers. CSF proteomic analysis reveals altered inflammatory and neurodegenerative metabolic pathways, providing valuable insights into the proteomic landscape of sALS. Several dysregulated proteins were consistent with the disease mechanisms highlighted in previous studies. These findings represent a step forward in developing personalised approaches for diagnosing and managing the disease.

Humans↗

Rapid on-line extraction and quantification of escitalopram from urine using sol-gel columns and mass spectrometric detection.

A fast and easy way to quantify escitalopram in urine has been developed. A capillary with a silica based monolithic bed inside is used to extract escitalopram from urine and the for mass spectrometry detrimental matrix is washed away by applied pressure. The analyte is eluted by a solution containing organic modifier and directly electrosprayed into a time-of-flight mass spectrometer, ESI-TOF-MS. This method makes it possible to load large volumes of sample onto the column and preconcentrate escitalopram on-line before detection. Standard addition of escitalopram to the urine sample gave a linear calibration curve (R(2)=0.988). The analyzed sample was found to contain an escitalopram concentration of 0.62 ng/ml, well in line with earlier publications. The calculated LOD was 10 pg/ml and LOQ was 34 pg/ml as compared to earlier reports with a LLOQ of 1 ng/ml. The intra day variation of the escitalopram peak area is less than 6.3%.

Antidepressive Agents↗

Bio-inspired, side-on attachment of a ruthenium photosensitizer to an iron hydrogenase active site model.

The first ruthenium-diiron complex [(mu-pdt)Fe2(CO)5{PPh2(C6H4CCbpy)}Ru(bpy)2]2+ 1 (pdt = propyldithiolate, bpy = 2,2'-bipyridine) is described in which the photoactive ruthenium trisbipyridyl unit is linked to a model of the iron hydrogenase active site by a ligand directly attached to one of the iron centers. Electrochemical and photophysical studies show that the light-induced MLCT excited state of the title complex is localized towards the potential diiron acceptor unit. However, the relatively mild potential required for the reduction of the acetylenic bipyridine together with the easily oxidized diiron portion leads to a reductive quenching of the excited state, instead. This process results in a transiently oxidized diiron unit which may explain the surprisingly high light sensitivity of complex 1.

Binding Sites↗

On-line biological sample cleanup for electrospray mass spectrometry using sol-gel columns.

Using a slight overpressure, a urine sample is loaded onto a monolithic photopolymerized sol-gel column that has been derivatized with hydrophobic carbon chains and then the complex urine matrix is washed with aqueous solution. A buffer containing organic solvent is used to elute the adsorbed peptides by an applied voltage and the sample is then introduced into a mass spectrometer by sheath flow electrospray. The importance of desalting this type of sample is demonstrated by an experiment that shows that the signal intensity of a test solution with neurotensin, sprayed directly into the mass spectrometer, decreased from 4.5x10(4) cps to no detectible signal when just 10% urine is added to the sample solution. We suggest that this procedure may find general application for desalting biological samples prior to mass spectrometric analysis.

Chromatography, Liquid↗

Photoinduced energy transfer coupled to charge separation in a Ru(II)-Ru(II)-acceptor triad.

The bichromophoric system Ru-Ru(C)-PI ([(bpy)3Ru-Ph-Ru(dpb)(Metpy-PI)][PF6]3, where bpy is 2,2'-bipyridine, Hdpb is 1,3-di(2-pyridyl)-benzene, Metpy is 4'-methyl-2,2':6',2' '-terpyridine and PI is pyromellitimide) containing two Ru(II) polypyridyl chromophores with a N6 and a N5C ligand set, respectively, was synthesized and characterized. Its photophysical properties were investigated and compared to those of the monochromophoric cyclometalated complexes Ru(C)-PI ([Ru(dpb)(Metpy-PI)][PF6]), Ru(C)-phi-PI ([Ru(dpb)(ttpy-PI)][PF6], ttpy is 4'-p-tolyl-2,2':6',2' '-terpyridine), Ru(C)-phi ([Ru(dpb)(ttpy)][PF6]), and Ru(C) ([Ru(dpb)(Metpy)][PF6]). Excitation of the Ru(C) unit in the dyads leads to oxidative quenching, forming the Ru(C)(III)-phi-PI*- and Ru(C)(III)-Pl.- charge-separated (CS) states with k(f)(ET) = 7.7 x 10(7) s(-1) (CH3CN, 298 K) in the tolyl-linked Ru(C)-phi-PI and k(f)(ET) = 4.4 x 10(9) s(-1) (CH2Cl2, 298 K) in the methylene-linked Ru(C)-PI. In the Ru-Ru(C)-PI triad, excitation of the Ru(C) chromophore leads to dynamics similar to those in the Ru(C)-PI dyad, generating the Ru(II)-Ru(C)(III)-PI*- CS state, whereas excitation of the Ru unit results in an initial energy transfer (k(EnT) = 4.7 x 10(11) s(-1)) to the cyclometalated Ru(C) unit. Subsequent electron transfer to the PI acceptor results in the formation of the same Ru(II)-Ru(C)(III)-PI*- CS state with k(f)(ET) = 5.6 x 10(9) s(-1) that undergoes rapid recombination with k(b)(ET) = 1 x 10(10) s(-1) (CH2Cl2, 298 K). The fate of the Ru(II)-Ru(C)(III)-PI*- CS state upon a second photoexcitation was studied by pump-pump-probe experiments in an attempt to detect the fully charge-separated Ru(III)-Ru(C)(II)-PI*- state.

Chromatography, High Pressure Liquid↗

A simplified multidimensional approach for analysis of complex biological samples: on-line LC-CE-MS.

Information on protein expression, disease biomarkers or surrogate markers and genetic disorders can nowadays be achieved from analysis of complex biological samples by liquid separation coupled to mass spectrometric (MS) detection. This paper describes fast multidimensional separation by on-line liquid chromatography (LC) and capillary electrophoresis (CE), followed by electrospray ionization (ESI) Fourier transform ion cyclotron resonance (FTICR) MS detection. This detector provides ultrahigh resolution of the detected ions, mass accuracy at the ppm-level and high sensitivity. Most of the challenge of this system lies in the development of a new interface for the on-line coupling of LC to CE. The interface developed in poly(dimethylsiloxane) provides a RSD for injection repeatability of <3.5% and surface control for unspecific binding by deactivation with a cationic polymer, PolyE-323. We have evaluated the interface, as well as the overall system, with respect to robustness and deconvolution ability. Sequence coverage for bovine serum albumin (BSA) of 93% showed a high recovery of sample in the different transfer steps through the system. The detection limit for identification is 277 ng mL(-1) (or 280 nM) on average for peptides. In the future, we expect LC-CE-MS to be a novel strategy for elucidating the chemistry of biological matrices.

Animals↗

Novel adsorptive polyamine coating for enhanced capillary electrophoresis of basic proteins and peptides.

In capillary electrophoresis (CE), the anionic and hydrophobic nature of the fused-silica capillary surface has long been known to present a problem in protein and peptide analysis. The use of capillary surface coating is one of the approaches to avoid the analyte-wall interactions. In this study, a new polymer, poly-LA 313, has been synthesized, physico-chemical characterized, and applied as polyamine coating for CE separations. The coating process is highly reproducible and provides fast separations of peptides and proteins in a few minutes and with high efficiency. The physically adsorbed polymer gives rise to a durable coating in the range of pH 2-10, in the presence of organic modifiers (acetonitrile and methanol) and with complex biological samples. The efficiency of the new cationic polymer was also tested performing protein and peptide separations with capillary electrophoresis-electrospray ionization-mass spectrometry (CE-ESI-MS).

Adsorption↗

Divergent activities of human glutathione transferases in the bioactivation of azathioprine.

Azathioprine is a thiopurine prodrug clinically used for immunosuppression in the treatment of inflammatory diseases and in pharmacological regimens of organ transplantations. Its pharmacological action is based on the release of 6-mercaptopurine, but the biochemical processes underlying this biotransformation have remained obscure. In this investigation, human glutathione transferases (GSTs) from seven distinct classes were assayed with azathioprine. GSTs A1-1, A2-2, and M1-1, all abundantly expressed in human liver, displayed the highest activity among the 14 GSTs tested. The uncatalyzed reaction of azathioprine with glutathione was estimated to be less than 1% of the GST-catalyzed biotransformation. GST M1-1 is polymorphic with a frequently occurring null allele, and GSTs A1-1 and A2-2 show variable expression levels in human subjects, implying significant differences in the rate of 6-mercaptopurine release from azathioprine. Individuals expressing high GST activity are apparently predisposed for adverse reactions to azathioprine treatment, both by promoting excessively high concentrations of free 6-mercaptopurine and its toxic metabolites and by depleting cellular glutathione. These novel aspects of GST-dependent azathioprine biotransformation have not been considered previously.

Azathioprine↗

Urine profiling using capillary electrophoresis-mass spectrometry and multivariate data analysis.

This work presents the development of a general and fast method for metabolic profiling of urine, using capillary electrophoresis-electrospray ionisation mass spectrometry (CE-ESIMS) and multivariate data analysis (DA). Human urine samples collected before and after ingestion of paracetamol were analysed at acidic and basic CE conditions, using both positive and negative ESI-MS detection. Analysis of the entire resulting data set, with no prior knowledge of the target compounds, using pair-wise 'fuzzy' correlation and eigenvalue analysis enabled the samples to be discriminated between on the basis of blank urine and urine collected after drug intake. By generating two-dimensional loadings plots, it was also possible to identify the m/z values of the substances responsible for the differentiation between control and dosed samples.

Acetaminophen↗

Noncovalent interaction between amyloid-beta-peptide (1-40) and oleuropein studied by electrospray ionization mass spectrometry.

Beta amyloid peptide (Abeta) is the major proteinaceous component of senile plaques formed in Alzheimer's disease (AD) brain. The aggregation of Abeta is associated with neurodegeneration, loss of cognitive ability, and premature death. It has been suggested that oxidative stress and generation of free radical species have implications in the fibrillation of Abeta and its subsequent neurotoxicity. For this reason, it is proposed that antioxidants may offer a protective or therapeutic alternative against amyloidosis. This study is the first report of the formation of the noncovalent complex between Abeta or its oxidized form and the natural derived antioxidant oleuropein (OE) by electrospray ionization mass spectrometry (ESI MS). ESI MS allowed the real time monitoring of the complex formation between Abeta, OE, and variants thereof. Several experimental conditions, such as elevated orifice potential, low pH values, presence of organic modifier, and ligand concentration were examined, to assess the specificity and the stability of the formed noncovalent complexes.

Amyloid beta-Peptides↗

Sample pretreatment on a microchip with an integrated electrospray emitter.

This study presents a microbead-packed PDMS microchip with an integrated electrospray emitter for sample pretreatment prior to sheathless ESI-MS. We prove the concept of analytical functions integrated onto a cm-sized area of a single bulk material. The microchip consists of two PDMS substrates replicated from SU-8 fabricated silicon wafer masters, bonded together after oxidation by corona discharge treatment. The channel within the microchip contains a grid structure that was used to trap 5 microm hypercross-linked polystyrene beads. The beads acted as a medium for sample desalting and enrichment. Electrical contact for the sheathless ESI process was achieved by coating the integrated emitter with conductive graphite powder after applying a thin layer of PDMS as glue. The coating as well as the bond of the PDMS structures showed excellent durability. A continuous spray was obtained from the microchip for over 800 h in a long-term electrospray stability experiment. Desalting and enrichment of neuropeptides from a physiological salt solution was successful by loading the sample onto the packed beads, followed by a washing and an eluting step. The results were obtained and evaluated using a TOF MS. An LOD of approximately 20 fmol (loaded onto the beads) for angiotensin II was obtained from a sample of neuropeptides dissolved in physiological salt solution.

Dimethylpolysiloxanes↗

A generic stepwise optimization strategy for liquid chromatography electrospray ionization tandem mass spectrometry methods.

The feasibility and advantages of using sophisticated chemometric tools in combination with the execution of thoroughly planned experiments to determine experimental conditions for optimal performance of an LC-ESI-MS/MS analysis is demonstrated. A stepwise strategy is proposed, which provides a controlled optimization procedure of the chromatographic quality (in terms of separation among the sample constituents) and maximizes the mass spectrometric signal of the selected product ions. Design of experiments (DOE) and response surface methodology are applied throughout the procedure. The stepwise approach has the advantage of dealing with the different optimization criteria separately, i.e. first ensuring sufficient chromatographic separation, then maximizing the amount of precursor ion entering the mass spectrometer, and finally generating high amounts of selected product ions. The experiments are performed on a linear ion trap mass spectrometer. Retention mapping using the band-tracking model is applied during LC development, which facilitates the optimization of segmented gradients. A set of different siderophores, strong iron chelates, is used as the model substances.

Journal Article↗

A hybrid poly(dimethylsiloxane) microsystem for on-chip whole blood filtration optimized for steroid screening.

Miniaturized biochemical devices in glass, silicon and polymer materials are starting to find their way from the academic laboratories to real-life applications. However, most attention has been given to miniaturize the downstream functions of various microfluidic systems, leaving the sample introduction and preparation steps to more conventional, bulkier solutions. For point-of-care diagnostics in particular, it becomes crucial to be able to handle complex human samples in a miniaturized format.In this work, we report on a microsystem for on-chip sample preparation that is able to remove blood cells from whole blood. The hybrid system consists of a commercially available membrane filter incorporated into a poly(dimethylsiloxane) (PDMS) casted device. Membrane materials were evaluated on the bases of low nonspecific adsorption of free and protein-bound testosterone as analyte substance. The hybrid system including a hydrophilic polypropylene filter successfully removed blood cells from diluted human whole blood. Surface oxidation was sufficient to make the plasma filtrate flow through the membrane filter and the channel system by capillary force alone and thus no external pumping source was needed.

Biocompatible Materials↗

Focused proteomics in post-mortem human spinal cord.

With a highly sensitive electrospray ionization-Fourier transform ion cyclotron resonance mass spectrometry (ESI-FTICR MS) system, proteins were identified in minimal amounts of spinal cord from patients with the neurodegenerative disease amyotrophic lateral sclerosis (ALS) and compared to proteins in spinal cord from control subjects. The results show 18 versus 16 significantly identified (p < 0.05) proteins, respectively, all known to be found in the central nervous system. The most abundant protein in both groups was the glial fibrillary acidic protein, GFAP. Other proteins were, for example, hemoglobin alpha- and beta chain, myelin basic protein, thioredoxin, alpha enolase, and choline acetyltransferase. This study also includes the technique of laser microdissection in combination with pressure catapulting (LMPC) for the dissection of samples and specific neurons. Furthermore, complementary experiments with nanoLC-matrix assisted laser desorption ionization time-of-flight tandem mass spectrometry (MALDI-TOF-TOF MS) confirmed the results of the ESI-FTICR MS screening and provided additional results of further identified proteins.

Amyotrophic Lateral Sclerosis↗

Sulfatide with short fatty acid dominates in astrocytes and neurons.

Glycosphingolipids are located in cell membranes and the brain is especially enriched. We speculated that the subcellular location of glycosphingolipids depends on their fatty acid chain length because their sugar residues are constant, whereas fatty acid chain length can vary within the same molecule. To test this hypothesis we analysed the glycosphingolipid sulfatide, which is highly abundant in myelin and has mostly long fatty acids. We used a negative ion electrospray tandem mass spectrometry precursor ion scan to analyse the molecular species of sulfatide in cultured astrocytes and a mouse model of the human disease metachromatic leukodystrophy. In these arylsulfatase A (ASA)-deficient mice sulfatide accumulates intracellularly in neurons and astrocytes. Immunocytochemistry was also performed on cultured astrocytes and analysed using confocal laser scanning microscopy. Analyses of the molecular species showed that cultured astrocytes contained sulfatide with a predominance of stearic acid (C18), which was located in large intracellular vesicles throughout the cell body and along the processes. The same was seen in ASA-deficient mice, which accumulated a higher proportion (15 mol% compared with 8 mol% in control mice) of sulfatide with stearic acid. We conclude that the major fatty acid composition of sulfatide differs between white and grey matter, with neurons and astrocytes containing mostly short-chain fatty acids with an emphasis on stearic acid. Based on our results, we speculate that the fatty acid chain length of sulfatide might determine its intracellular (short chain) or extracellular (long chain) location and thereby its functions.

Animals↗

Brain lipid composition in postnatal iron-induced motor behavior alterations following chronic neuroleptic administration in mice.

Several studies have shown that deficient uptake or excessive break down of membrane phospholipids may be associated with neurodegenerative and psychiatric disorders. The purpose of the present study was to examine the effects of postnatal iron administration in lipid composition and behavior and whether or not the established effects may be altered by subchronic administration of the neuroleptic compounds, clozapine and haloperidol. In addition to motor activities such as locomotion, rearing and activity, a targeted lipidomics approach has been used to investigated the brains of eight groups of mice (four vehicle groups and four iron groups) containing six individuals in each group treated with vehicle, low dose clozapine, high dose clozapine and haloperidol. Lipids were extracted by the Folch method and analyzed using reversed-phase capillary liquid chromatography coupled on-line to electrospray ionization mass spectrometry (LC/ESI/MS). Identification of phosphatidylcholine (PC) and sphingomyelin (SM) molecular species was based on their retention time, m/z ratio, head group specific up-front fragmentation and analysis of the product ions produced upon fragmentation. A comparison between the Ve-groups and Fe-groups showed that levels of PC and SM molecular species and motor activities were significantly lower in Fe-Ve compared to Ve-Ve. The effects of neuroleptic treatment with and without iron supplementation were studied. In conclusion our results support the hypothesis that an association between psychiatric disorders and lipid and behavior abnormalities in the brain exists.

Animals↗

Bioactive heparin immobilized onto microfluidic channels in poly(dimethylsiloxane) results in hydrophilic surface properties.

A new composition of heparin coating for microfluidic systems made out of poly(dimethylsiloxane) (PDMS) was developed and evaluated. The coating that consists of a conditioning polyamine layer followed by two heparin/glutaraldehyde layers, resulted in channel surfaces with sufficient wettability to obtain flow of human normal plasma by capillary force alone. Hydrophilic channel walls are a desirable characteristic in microfluidic devices, since alternative pumping mechanisms must otherwise be included into the system. The immobilized heparin showed high antithrombin-binding capacity and a low degree of blood-material interaction. Plasma in contact with heparin-coated PDMS formed no detectable fibrin in a spectrophotometric assay by which plasma in contact with non-treated PDMS showed complete coagulation. The quartz crystal microbalance technique with energy dissipation monitoring (QCM-D) was utilized to obtain detailed information regarding adsorption kinetics and structural properties of the different layers composing the heparin coating.

Blood Flow Velocity↗