PubMed Health⌕ Search

Biomedical subjects

Jonas Johansson

Publications and source records attributed to Jonas Johansson.

11 recordsLinked to original sources

Structural properties of <111>B -oriented III-V nanowires.

Controlled growth of nanowires is an important, emerging research field with many applications in, for example, electronics, photonics, and life sciences. Nanowires of zinc blende crystal structure, grown in the <111>B direction, which is the favoured direction of growth, usually have a large number of twin-plane defects. Such defects limit the performance of optoelectronic nanowire-based devices. To investigate this defect formation, we examine GaP nanowires grown by metal-organic vapour-phase epitaxy. We show that the nanowire segments between the twin planes are of octahedral shape and are terminated by {111} facets, resulting in a microfaceting of the nanowires. We discuss these findings in a nucleation context, where we present an idea on how the twin planes form. This investigation contributes to the understanding of defect formation in nanowires. One future prospect of such knowledge is to determine strategies on how to control the crystallinity of nanowires.

Journal Article↗

Characterization of different laser irradiation methods for quantitative Raman tablet assessment.

Quantitative Raman spectroscopy of conventional wet granulated pharmaceutical immediate release tablets and subsequent data evaluation was investigated. Different aspects of quantitative assessment of active pharmaceutical ingredient (API) in intact tablets with special focus on sub-sampling issues were addressed. Four different geometric laser irradiance patterns were examined to study the effect of sub-sampling within the tablets. The Raman data was evaluated using both univariate and multivariate techniques. UV absorbance spectroscopy was used as a reference method. The best result in terms of prediction error was attained by irradiating a large area of the tablets. Using multivariate calibration with multiplicative signal correction (MSC) the prediction error was 1.7%. In addition, the effect of tablet density on the Raman assessment was investigated. It was found that quantitative Raman assessment of chemical content can be made insensitive to variations in tablet density corresponding to a manufacturing compression interval of 5-20 kN provided that adequate data treatment is used. A short discussion about sample heating in the context of different irradiation patterns is included with reference to previous work. In conclusion, the present study provides a platform for developing an implementation strategy for quantitative Raman spectroscopy for both laboratory analysis and process analytical technology (PAT) applications.

Calibration↗

Mass transport model for semiconductor nanowire growth.

We present a mass transport model based on surface diffusion for metal-particle-assisted nanowire growth. The model explains the common observation that for III/V materials thinner nanowires are longer than thicker ones. We have grown GaP nanowires by metal-organic vapor phase epitaxy and compared our model calculations with the experimental nanowire lengths and radii. Moreover, we demonstrate that the Gibbs-Thomson effect can be neglected for III/V nanowires grown at conventional temperatures and pressures.

Journal Article↗

Time-resolved NIR spectroscopy for quantitative analysis of intact pharmaceutical tablets.

Near-infrared (NIR) spectroscopy is a useful technique for quantitative measurements of intact tablets, but it suffers from limitations due to the fact that changes in the physical properties of a sample strongly affect the recorded spectrum. In this work, time-resolved transmission NIR spectroscopy was utilized to conduct quantitative measurements of intact tablets. The technique enables separation of the absorption properties of the sample from the scattering properties and can therefore handle changes of the physical parameters of the samples in a better way than conventional NIR transmission spectroscopy. The experiments were conducted using a pulsed Ti:sapphire laser coupled into a nonlinear photonic crystal fiber as light source. The light transmitted through the sample was measured by a time-resolving streak camera. A comparison of the results from the time-resolved technique with the results from conventional transmission NIR spectroscopy was made using tablets containing different concentrations of iron oxide and manufactured with different thicknesses. A PLS model made with data from the time-resolved technique predicted samples 5 times better than a PLS model made data from the conventional NIR transmission technique. Furthermore, an improvement to predict samples with physical properties outside those included in the calibration set was demonstrated.

Calibration↗

Scatter correction of transmission near-infrared spectra by photon migration data: quantitative analysis of solids.

The scope of this work is a new methodology to correct conventional near-infrared (NIR) data for scattering effects. The technique aims at measuring the absorption coefficient of the samples rather than the total attenuation measured in conventional NIR spectroscopy. The main advantage of this is that the absorption coefficient is independent of the path length of the light inside the sample and therefore independent of the scattering effects. The method is based on time-resolved spectroscopy and modeling of light transport by diffusion theory. This provides an independent measure of the scattering properties of the samples and therefore of the path length of light. This yields a clear advantage over other preprocessing techniques, where scattering effects are estimated and corrected for by using the shape of the measured spectrum only. Partial least squares (PLS) calibration models show that, by using the proposed evaluation scheme, the predictive ability is improved by 50% as compared to a model based on conventional NIR data alone. The method also makes it possible to predict the concentration of active substance in samples with other physical properties than the samples included in the calibration model.

Algorithms↗

Potential outcomes of modalities and techniques in radiotherapy for patients with hypopharyngeal carcinoma.

BACKGROUND AND PURPOSE: To determine potential improvements in treatment outcome for patients with hypopharyngeal carcinoma, T4N0M0, using proton and intensity modulated photon radiotherapy (IMRT) compared to a standard 3D conformal radiotherapy treatment (3D-CRT) in terms of local tumour control probability, TCP, and normal tissue complication probability (NTCP) for the spinal cord and the parotid glands using. PATIENTS AND METHODS: Using the three-dimensional treatment-planning system, Helax-TMS, 5 patients were planned with protons, IMRT, and 3D-CRT plans. The prescribed dose used was 30 fractions x 2.39 Gy for the protons and IMRT and 35 fractions x 2.00 Gy for 3D-CRT. The treatment plans were evaluated using dose volume data and dose response models were used to calculate TCP and NTCP. The target volumes were delineated to spare the parotid glands. A dose escalation was made for protons and IMRT using NTCP constraints to the spinal cord. RESULTS: On average, protons and IMRT increase TCP by 17% compared to 3D-CRT. For the spinal cord NTCP values are zero for all methods and patients. Average NTCP values for the parotid glands were >90% for 3D-CRT and significantly lower for protons and IMRT varying from 43-65%. The average parotid gland dose was 33 Gy for the protons, 38 Gy for IMRT and 48 Gy for 3D-CRT. CONCLUSIONS: Protons and IMRT gave a significant TCP increase compared to 3D-CRT while no significant difference between protons and IMRT was found. Protons generally show lower non-target tissue doses, which indicates a possibility for further dose escalation. Large individual dose differences between protons and IMRT for parotid glands indicate that some patients may benefit more from protons and others from IMRT.

Carcinoma↗

Habitat-specific pigmentation in a freshwater isopod: adaptive evolution over a small spatiotemporal scale.

Pigmentation in the freshwater isopod Asellus aquaticus (Crustacea) differed between habitats in two Swedish lakes. In both lakes, isopods had lighter pigmentation in stands of submerged vegetation, consisting of stoneworts (Chara spp.), than in nearby stands of reed (Phragmites australis). Experimental crossings of light and dark isopods in a common environment showed that pigmentation had a genetic basis and that genetic variance was additive. Environmental effects of diet or chromatophore adjustment to the background had minor influence on pigmentation, as shown by laboratory rearing of isopods on stonewort or reed substrates, as well as analyses of stable isotope ratios for isopods collected in the field. In both study lakes, the average phenotype became lighter with time (across generations) in recently established stonewort stands. Taken together, these results indicate that altered phenotype pigmentation result from evolutionary responses to local differences in natural selection. Based on the assumption of two generations per year, the evolutionary rate of change in pigmentation was 0.08 standard deviations per generation (haldanes) over 20 generations in one lake and 0.22 haldanes over two generations in the other lake. This genetic change occurred during an episode of population growth in a novel habitat, a situation known to promote adaptive evolution. In addition, stonewort stands constitute large and persistent patches, characteristics that tend to preserve local adaptations produced by natural selection. Results from studies on selective forces behind the adaptive divergence suggest that selective predation from visually oriented predators is a possible selective agent. We found no indications of phenotype-specific movements between habitats. Mating within stonewort stands was random with respect to pigmentation, but on a whole-lake scale it is likely that mating is assortative, as a result of local differences in phenotype distribution.

Adaptation, Physiological↗

Airborne chemistry coupled to Raman spectroscopy.

In this paper, the use of airborne chemistry (acoustically levitated drops) in combination with Raman spectroscopy is explored. We report herein the first Raman studies of crystallization processes in levitated drops and the first demonstration of surface-enhanced Raman scattering (SERS) detection in this medium. Crystallization studies on the model compounds benzamide and indomethacin resulted in the formation of two crystal modifications for each compound, suggesting that this methodology may be useful for investigation of polymorphs. SERS detection resulted in a signal enhancement of 27 000 for benzoic acid and 11 000 for rhodamine 6-G. The preliminary results presented here clearly indicate that several important applications of the combination between Raman spectroscopy and acoustic drop levitation can be expected in the future.

Journal Article↗

Infrared imaging of laser-induced heating during Raman spectroscopy of pharmaceutical solids.

Raman spectroscopy is finding increasing popularity as an analytical technique for the analysis of pharmaceutical powders and solid dosage forms. It is well known that illumination by the high intensity lasers used in Raman spectrometers can result in sample heating, however, the extent of the problem has not been assessed for pharmaceutically relevant materials. Using direct thermal imaging of compressed powders, the extent of heating for microcrystalline cellulose (MCC), vanillin, ibuprofen and stearic acid was measured as a function of laser intensity. MCC was found to be the most susceptible to sample heating while ibuprofen was least sensitive. At high laser powers (1.5 W), samples were heated by between 38 and 60 degrees C while at more moderate laser powers (0.7 W) the degree of heating was between 20 and 30 degrees C. The kinetics of the heating process were mathematically modeled for MCC and the derived constants were used to predict the rotation speed necessary to prevent a solid state transition in a heat sensitive compound, theophylline monohydrate. Experimental measurements at different rotation speeds verified that the estimated rotation speed reduced sample heating by the desired amount. In conclusion, the extent of heating is clearly of some concern for pharmaceutical materials but can be substantially reduced by sample rotation.

Hot Temperature↗

Multiple fiber-optic dual-beam UV/Vis system with application to dissolution testing.

A system for fiber-optic probing in dissolution testing of solid pharmaceutical formulations has been constructed. The system is based on an imaging spectrometer and a charged coupled device (CCD) detector and includes 12 fiber-optic probes with a novel dual-path design. UV light was produced by a small arc deuterium lamp illuminating an optical fiber bundle. Twelve fiber-optic dipping probes were constructed with a reflection geometry. A 5 mm diameter lens was used to achieve a parallel light beam. The light passed back and forth through the flow-through cuvette defined by a sapphire window and a coated aluminium mirror. The mirror was cut in half and each segment was tilted and set at different distances from the window to obtain two separate paths with different lengths. Two receiver fibers were used for each probe to collect the transmitted light. The 24 receiver fibers from the 12 probes were bunched to a linear bundle and fed to an imaging spectrometer and the corresponding spectra were detected with a 512 x 512 pixel cooled CCD detector. The sampling interval was typically a few seconds for all probes. A software package was developed for data recording and on-line analysis. The program includes tools for multi-component analysis. The system was tested for different tablet formulations. Prednisone 50 mg tablets, normally used for control tests of dissolution baths, were followed for 3 h. Secondly, an extended release low dosage tablet was followed for 7 h resulting in a linear dissolution profile. Finally, a combination tablet containing two active drugs was tested for 60 min profiles. In the latter case, separate dissolution curves for the two active components were obtained. Future work will mainly focus on further development of the multi-component capability of the system.

Chemistry, Pharmaceutical↗

Node-positive left-sided breast cancer patients after breast-conserving surgery: potential outcomes of radiotherapy modalities and techniques.

PURPOSE: To determine how much proton and intensity modulated photon radiotherapy (IMRT) can improve treatment results of node-positive left-sided breast cancer compared to conventional radiation qualities (X-rays and electrons) after breast-conserving surgery in terms of lower complication risks for cardiac mortality and radiation pneumonitis. METHODS AND MATERIAL: For each of 11 patient studies, one proton plan, one IMRT, and two conventional (tangential and patched) plans were calculated using a three-dimensional treatment-planning system, Helax-TMS(). The evaluation of the different treatment plans was made by applying the normal tissue complication probability model (NTCP) proposed by Källman (also denoted the relative seriality model) on the dose distributions in terms of dose-volume histograms. The organs at risk are the spinal cord, the left lung, the heart, and the non-critical normal tissues (including the right breast). RESULTS: The comparison demonstrated that the proton treatment plans provide significantly lower NTCP values for the heart and lung when compared to conventional radiation qualities including IMRT for all 11 patients. At a prescribed dose of 50 Gy in the PTV, the calculated mean NTCP value for the patients decreased, on the average, from 14.7 to 0.6% for the lung (radiation pneumonitis) for the proton plans compared with the best plan using conventional radiation qualities. The corresponding figures for the heart (cardiac mortality) were from 2.1 to 0.5%. The figures for cardiac mortality for IMRT, tangential technique and the patched technique were 2.2, 6.7, and 2.1%, respectively. CONCLUSIONS: Protons appear to have major advantages in terms of lower complication risks when compared with treatments using conventional radiation qualities for treating node-positive left-sided breast cancer after breast-conserving surgery.

Breast Neoplasms↗