PubMed Health⌕ Search

Biomedical subjects

Jonas Korlach

Publications and source records attributed to Jonas Korlach.

5 recordsLinked to original sources

Achieving uniform mixing in a microfluidic device: hydrodynamic focusing prior to mixing.

We describe a microfluidic mixer that is well-suited for kinetic studies of macromolecular conformational change under a broad range of experimental conditions. The mixer exploits hydrodynamic focusing to create a thin jet containing the macromolecules of interest. Kinetic reactions are triggered by molecular diffusion into the jet from adjacent flow layers. The ultimate time resolution of these devices can be restricted by premature contact between co-flowing solutions during the focusing process. Here, we describe the design and characterization of a mixer in which hydrodynamic focusing is decoupled from the diffusion of reactants, so that the focusing region is free from undesirable contact between the reactants. Uniform mixing on the microsecond time scale is demonstrated using a device fabricated by imprinting optical-grade plastic. Device characterization is carried out using fluorescence correlation spectroscopy (FCS) and two-photon microscopy to measure flow speeds and to quantify diffusive mixing by monitoring the collisional fluorescence quenching, respectively. Criteria for achieving microsecond time resolution are described and modeled.

Microfluidics↗

Detection of motional heterogeneities in lipid bilayer membranes by dual probe fluorescence correlation spectroscopy.

We report the detection of heterogeneities in the diffusion of lipid molecules for the three-component mixture dipalmitoyl-PC/dilauroyl-PC/cholesterol, a chemically simple lipid model for the mammalian plasma membrane outer leaflet. Two-color fluorescence correlation spectroscopy (FCS) was performed on giant unilamellar vesicles (GUVs) using fluorescent probes that have differential lipid phase partition behavior--DiO-C18:2 favors disordered fluid lipid phases, whereas DiI-C20:0 prefers spatially ordered lipid phases. Simultaneously-obtained fluorescence autocorrelation functions from the same excitation volume for each dye showed that, depending on the lipid composition of this ternary mixture, the two dyes exhibited different lateral mobilities in regions of the phase diagram with previously proposed submicroscopic two-phase coexistence. In one-phase regions, both dyes reported identical diffusion coefficients. Two-color FCS thus may be detecting local membrane heterogeneities at size scales below the optical resolution limit, either due to short-range order in a single phase or due to submicroscopic phase separation.

1,2-Dipalmitoylphosphatidylcholine↗

Focal volume confinement by submicrometer-sized fluidic channels.

Microfluidic channels with two lateral dimensions smaller than 1 microm were fabricated in fused silica for high-sensitivity single-molecule detection and fluorescence correlation spectroscopy. The effective observation volumes created by these channels are approximately 100 times smaller than observation volumes using conventional confocal optics and thus enable single-fluorophore detection at higher concentrations. Increased signal-to-noise ratios are also attained because the molecules are restricted to diffuse through the central regions of the excitation volume. Depending on the channel geometries, the effective dimensionality of diffusion is reduced, which is taken into account by simple solutions to diffusion models with boundaries. Driven by electrokinetic forces, analytes could be flowed rapidly through the observation volume, drastically increasing the rate of detection events and reducing data acquisition times. The statistical accuracy of single-molecule characterization is improved because all molecules are counted and contribute to the analysis. Velocities as high as 0.1 m/s were reached, corresponding to average molecular residence times in the observation volume as short as 10 micros. Applications of these nanofabricated devices for high-throughput, single-molecule detection in drug screening and genomic analysis are discussed.

Kinetics↗

Spontaneous nucleotide exchange in low molecular weight GTPases by fluorescently labeled gamma-phosphate-linked GTP analogs.

Regulated guanosine nucleotide exchange and hydrolysis constitute the fundamental activities of low molecular weight GTPases. We show that three guanosine 5'-triphosphate analogs with BODIPY fluorophores coupled via the gamma phosphate bind to the GTPases Cdc42, Rac1, RhoA, and Ras and displace guanosine 5'-diphosphate with high intrinsic exchange rates in the presence of Mg(2+) ions, thereby acting as synthetic, low molecular weight guanine nucleotide exchange factors. The accompanying large fluorescence enhancements (as high as 12-fold), caused by a reduction in guanine quenching of the environmentally sensitive BODIPY dye fluorescence on protein binding, allow for real-time monitoring of this spontaneous nucleotide exchange in the visible spectrum with high signal-to-noise ratios. Binding affinities increased with longer aliphatic linkers connecting the nucleotide and BODIPY fluorophore and were in the 10-100 nM range. Steady-state and time-resolved fluorescence spectroscopy showed an inverse relationship between linker length and fluorescence enhancement factors and differences in protein-bound fluorophore mobilities, providing optimization criteria for future applications of such compounds as efficient elicitors and reporters of nucleotide exchange. EDTA markedly enhanced nucleotide exchange, enabling rapid loading of GTPases with these probes. Differences in active site geometries, in the absence of Mg(2+), caused qualitatively different reporting of the bound state by the different analogs. The BODIPY analogs also prevented the interaction of Cdc42 with p21 activated kinase. Together, these results validate the use of these analogs as valuable tools for studying GTPase functions and for developing potent synthetic nucleotide exchange factors for this important class of signaling molecules.

Boron Compounds↗

DNA fragment sizing by single molecule detection in submicrometer-sized closed fluidic channels.

The fabrication of fluidic channels with dimensions smaller than 1 microm is described and characterized in respect to their use for detection of individual DNA molecules. The sacrificial layer technique is used to fabricate these devices as it provides CMOS-compatible materials exhibiting low fluorescence background. It also allows creating microfluidics circuitry of submicrometer dimensions with great control. The small dimensions facilitate single molecule detection and minimize events of simultaneous passage of more than one molecule through the measurement volume. The behavior of DNA molecules inside these channels under an applied electrical field was first studied by fluorescence correlation spectroscopy using M13 double-stranded DNA. A linear relationship between the flow speed and applied electric field across the channel was observed. Speeds as high as 5 mm/s were reached, corresponding to only a few milliseconds of analysis time per molecule. The channels were then used to characterize a mixture of nine DNA fragments. Both the distribution and relative proportions of the individual fragments, as well as the overall concentration of the DNA sample, can be deduced from a single experiment. The amount of sample required for the analysis was approximately 10,000 molecules, or 76 fg. Other potential applications of these submicrometer structures for DNA analysis are discussed.

DNA↗