Jonas Svensson

Publications and source records attributed to Jonas Svensson.

5 recordsLinked to original sources

Hyperpolarized 13C MR angiography using trueFISP.

A (13)C-enriched water-soluble compound (bis-1,1-(hydroxymethyl)-1-(13)C-cyclopropane-D(8)), with a (13)C-concentration of approximately 200 mM, was hyperpolarized to approximately 15% using dynamic nuclear polarization, and then used as a contrast medium (CM) for contrast-enhanced magnetic resonance angiography (CE-MRA). The long relaxation times (in vitro: T(1) approximately 82 s, T(2) approximately 18 s; in vivo: T(1) approximately 38 s, T(2) approximately 1.3 s) are ideal for steady-state free precession (SSFP) imaging with a true fast imaging and steady precession (trueFISP) pulse sequence. It was shown both theoretically and experimentally that the optimal flip angle was 180 degrees. CE-MRA was performed in four anesthetized live rats after intravenous injection of 3 ml CM. The angiograms covered the thoracic/abdominal region in two of the animals, and the head-neck region in the other two. Fifteen consecutive images were acquired in each experiment, with a flip-back pulse at the end of each image acquisition. In the angiograms, the vena cava (SNR approximately 240), aorta, renal arteries, carotid arteries (SNR approximately 75), jugular veins, and several other vessels were visible. The SNR in the cardiac region was 500. Magnetization was preserved from one image acquisition to the next using the flip-back technique (SNR(cardiac) approximately 10 in the 15th image).

Animals↗

Contrast-enhanced magnetic resonance angiography: development and optimization of techniques for paramagnetic and hyperpolarized contrast media.

Contrast-enhanced magnetic resonance angiography (CE-MRA) is a diagnostic method for imaging of vascular structures based on nuclear magnetic resonance. Vascular enhancement is achieved by injection of a contrast medium (CM). Studies were performed using two different types of CM: conventional paramagnetic CM, and a new type of CM based on hyperpolarized (HP) nuclei. The effects of varying CM concentration with time during image acquisition were studied by means of computer simulations using two different models. It was shown that a rapid concentration variation during encoding of the central parts of k-space could result in signal loss and severe image artifacts. The results were confirmed qualitatively with phantom experiments. A postprocessing method was developed to address problems with simultaneous enhancement of arteries and veins in CE-MRA of the lower extremities. The method was based on the difference in flow-induced phase in the two vessel types. Evaluation of the method was performed with flow phantom measurements and with CE-MRA in two volunteers using standard pulse sequences. The flow-induced phase in the vessels of interest was sufficient to distinguish arteries from veins in the superior-inferior direction. Using this method, the venous enhancement could be extinguished. The possibility of using HP nuclei as CM for CE-MRA was evaluated. Signal expressions for a flow of HP CM imaged with a gradient echo sequence were derived. These signal expressions were confirmed in phantom experiments using HP 129Xe dissolved in ethanol. Studies were also performed with a new CM based on HP 13C. The CM had very long relaxation times (T1, in vivo/T2, in vivo approximately 38/1.3 s). The long relaxation times were utilized in imaging with a fully balanced steady-state free precession pulse sequence (trueFISP), where the optimal flip angle was found to be 180 degrees. CE-MRA with the 13C-based CM in rats resulted in images with high vascular SNR (approximately 500). CE-MRA is a useful clinical tool for diagnosing vascular disease. With the development of new contrast media, based on hyperpolarized nuclei for example, there is a potential for further improvement in the signal levels that can be achieved, enabling a standard of imaging of vessels that is not possible today.

Animals↗

Quantitative measurement of regional lung ventilation using 3He MRI.

A new strategy for a quantitative measurement of regional pulmonary ventilation using hyperpolarized helium-3 (3He) MRI has been developed. The method employs the build-up of the signal intensity after a variable number of (3)He breaths. A mathematical model of the signal dynamics is presented, from which the local ventilation, defined as the fraction of gas exchanged per breath within a given volume, is calculated. The model was used to create ventilation maps of coronal slices of guinea pig lungs. Ventilation values very close to 1 were found in the trachea and the major airways. In the lung parenchyma, regions adjacent to the hilum showed values of 0.6-0.8, whereas 0.2-0.4 was measured in peripheral regions. Monte Carlo simulations were used to investigate the accuracy of the method and its limitations. The simulations revealed that, at presently attainable signal-to-noise ratios, the ventilation parameter can be determined with a relative uncertainty of <5% over a wide range of values.

Animals↗

Separation of arteries and veins using flow-induced phase effects in contrast-enhanced MRA of the lower extremities.

In 3-D contrast-enhanced magnetic resonance (MR) angiography of the lower extremities the goal is most often to enhance arterial structures while keeping veins and surrounding tissue unenhanced. Imaging during steady-state concentration of a blood pool agent or during poor timing of an extra-cellular contrast medium may result in simultaneous venous enhancement, making interpretation of the angiogram difficult. The aim of this study was to develop a post-processing method to separate the arteries from the veins in standard contrast-enhanced MR angiograms. The method was based on the different accumulation of flow-induced phase in the arteries and veins of the lower extremities. The method was tested in both phantom experiments and volunteers undergoing 3-D contrast-enhanced MR angiography using both an extra-cellular contrast medium and a blood pool agent. In the phantom studies, opposite directional flow was successfully separated at mean flow velocities as low as 9 cm/s. In the volunteer studies, the larger veins were successfully extinguished while the larger arteries were left unaffected. In smaller vessels with low flow velocities the separation was less successful. This was most apparent in vessels not oriented superior-inferior. The method developed here is promising for separating arteries from veins in contrast-enhanced MR angiography although the results could be further improved by either a different pulse sequence design or combining this method with other segmentation methods.

Arteries↗

13C-angiography.

Explore the source record for details and available documents.

Animals↗