PubMed Health⌕ Search

Biomedical subjects

Jonathan Garino

Publications and source records attributed to Jonathan Garino.

4 recordsLinked to original sources

Minimum 10-year results of a tapered, titanium, hydroxyapatite-coated hip stem: an independent review.

The performance of, and periprosthetic bone response to, a tapered, titanium (Ti6Al4V), hydroxyapatite-coated femoral hip prosthesis was evaluated at minimum of 10 years of follow-up. Data were prospectively collected on 147 consecutive primary hip arthroplasties performed in 133 patients by a single surgeon during a 2-year interval. Clinical and radiographic analyses of 96 hips in 86 patients were independently performed by 2 surgeons who were not involved in the care of these patients. There were no cases of aseptic loosening of the femoral component. Subsidence and stress shielding occurred in 5% and 2% of cases, respectively, and was not clinically significant. In all 15 hips that required revision of the acetabular component, the femoral component was found to be well fixed, without any occurrence of distal osteolysis. This femoral design provided reliable osseointegration that was durable at a mean of 11.5 years of follow-up.

Adult↗

Excretion of resorption products from bioactive glass implanted in rabbit muscle.

Bioactive glass granules were implanted in the paraspinal muscle of rabbits to determine the pathway of the silicon released from bioactive glass in vivo. We traced and quantified the silicon released by obtaining 24-h urine and blood samples for up to 6 months after implantation. Furthermore, local muscle tissue as well as the following organs were resected for chemical and histopathological analyses: brain, heart, kidney, liver, lung, lymph nodes, spleen, and thymus. The urinary silicon of the group with implanted granules was significantly higher than in the sham-operated, control group. The average excretion rate was 2.4 mg/day, and as such, 100% of the implanted silicon was excreted in 19 weeks. No elevated concentrations of silicon were found at the implant sites or in the other organs at sacrifice, that is, 24 weeks. The histological appearance of all organs was normal throughout. The concentrations of silicon measured in the urine were well below saturation and because no significant increase in silicon was found in any organ, including kidney, the increased silicon excretion rate was within the physiological capacity of rabbits. Therefore, it can be concluded that the resorbed silica gel is harmlessly excreted in soluble form through the urine.

Animals↗

Silicon excretion from bioactive glass implanted in rabbit bone.

Bioactive glass granules were implanted in the tibiae of rabbits in order to determine the pathway of the silicon released from bioactive glass in vivo. We traced and quantified the silicon released by obtaining 24-h urine samples and blood samples for up to 7 months after implantation. Bone tissue as well as the following organs were resected for chemical and histopathological analyses: kidney, liver, lung, lymph nodes, and spleen. The urinary silicon of the implanted group was significantly higher than in the control group. From the data, the calculated average excretion rate was approximately 1.8 mg/day, and as such, the amount of implanted silicon was excreted within statistical bounds in 24 weeks. At this point, only elevated concentrations of silicon were found at the implant site and not in the other organs. The concentrations of silicon measured in the urine were well below saturation. Since no significant increase in silicon was found in any of the organs including the kidney, the increased silicon excretion rate was within the physiological capacity of rabbits. Therefore, it can be concluded that the resorbed silica gel is harmlessly excreted in soluble form through the urine.

Animals↗

Risk factors for pressure ulcers among elderly hip fracture patients.

The purpose of this study was to estimate the incidence of hospital-acquired pressure ulcers among elderly patients hospitalized for hip fracture surgery and to identify extrinsic factors that are associated with increased risk. We conducted a secondary analysis of data abstracted from medical records at 20 hospitals in Pennsylvania, Texas, New Jersey, and Virginia. Participants were patients aged 60 years and older admitted with hip fracture to the study hospitals between 1983 and 1993. The incidence of hospital-acquired pressure ulcers was 8.8% (95% confidence interval 8.2%-9.4%). After adjusting for confounding variables, longer wait before surgery, intensive care unit stay, longer surgical procedure, and general anesthesia were significantly associated with higher pressure ulcer risk. Extrinsic factors may be important markers for high pressure ulcer risk in hospitalized hip fracture patients. Although it is not possible to eliminate factors such as requiring an intensive care unit stay or having a long surgical procedure, it may be possible to develop interventions that minimize pressure ulcer risk in patients who experience these factors.

Aged↗