PubMed Health⌕ Search

Biomedical subjects

Jonathan J Rome

Publications and source records attributed to Jonathan J Rome.

13 recordsLinked to original sources

Endovascular stents for relief of cyanosis in single-ventricle patients with shunt or conduit-dependent pulmonary blood flow.

UNLABELLED: Hypoxemia is a significant cause of early and interstage death in patients with single ventricle (SV). Obstruction of Blalock-Taussig shunts (BTS) in patients with SV has traditionally been managed with surgical revision. PURPOSE: We report on the experience at our institution of deploying endovascular stents within BTS as well as obstructed right-ventricle (RV) to pulmonary artery (PA) conduits in patients with modified Norwood (ie Sano modification). METHODS: Medical records were reviewed for the time period between January 1, 2002 and November 30, 2005. All patients with SV who presented for intervention for BTS or RV-PA conduit stenosis were reviewed. Specific endpoints reviewed included pre- and post-intervention arterial oxygen saturation, type of intervention (stent vs. ballon dilation), need for subsequent surgical shunt/conduit revision, and interval to second stage palliation. RESULTS: Fifteen patients with SV underwent intervention for acute cyanosis. Eight patients had BTS, and the other seven patients had RV-PA conduit stenosis. Coronary stents were deployed in 14 of the 15 patients. Four patients also underwent balloon angioplasty of branch PAs. Oxygen saturations improved in all patients, with a mean increase of 13.9% (p = 0.0001). Four patients died before second stage palliation--one due to complications of the catheterization. Of the eleven remaining patients, nine have undergone second stage palliation; interval from intervention to Glenn ranged from 28-205 days (mean 163d). Two patients are awaiting cavo-pulmonary anastamosis. CONCLUSIONS: Endovascular stenting in this high-risk population is effective at improving oxygen saturation as well as obviating need to surgical shunt/conduit revision.

Angioplasty, Balloon, Coronary↗

Impact of re-coarctation following the Norwood operation on survival in the balloon angioplasty era.

OBJECTIVES: The objective of this study was to determine the efficacy of balloon angioplasty (BA) by comparing the immediate and long-term outcomes of patients with and without re-coarctation after a Norwood procedure. BACKGROUND: Although BA has become the standard means for treating recurrent coarctation following a Norwood operation, it has been suggested that re-coarctation remains a significant cause of morbidity and mortality. METHODS: Patients who survived a Norwood operation from December 1986 through June 2001 were studied. Differences between groups were evaluated by t test and logistic regression. Survival differences were tested by log-rank tests using Kaplan-Meier survival curves. RESULTS: Fifty-eight of 633 patients underwent treatment for re-coarctation (9.2%). Thirty-five patients underwent BA (before 1988, 23 had surgery). Median age at catheterization was 6.6 months (1.9 to 35.6 months). Balloon angioplasty was successful (gradient <10 mm Hg) in 32 of 35 patients (92%). There were no BA-related deaths or neurologic complications. Recurrent obstruction after BA occurred in seven patients (20%); five underwent re-dilation. Kaplan-Meier estimates of freedom from recurrent obstruction after initial BA were 97% at one month, 79% at one year, and 79% at five years. There were no differences in survival between patients with re-coarctation treated by BA and patients who did not undergo treatment for re-coarctation. CONCLUSIONS: We found that 9.2% of patients underwent treatment for re-coarctation following a Norwood operation. Balloon angioplasty is effective, with low morbidity, no early mortality, and no difference in long-term survival when compared with patients who did not have re-coarctation. Recurrent coarctation following BA occurred in 17% of patients, usually within the first year after BA.

Angioplasty, Balloon, Coronary↗

Novel approach to percutaneous stent implantation for coarctation of the aorta: the railway technique.

Percutaneous stent implantation is a widely accepted therapeutic procedure for recurrent coarctation of the aorta. Distal stent migration during deployment is not uncommon and can result in vascular dissection. The following report describes the creation of an arterial railway in two patients with coarctation. The railway allowed for stent placement with minimal movement of the balloon/stent assembly during deployment. This strategy may decrease the risk of stent malposition and could be particularly useful in cases where anatomy is difficult.

Adult↗

Evaluation of tissue saturation as a noninvasive measure of mixed venous saturation in children.

BACKGROUND: Mixed venous saturation (S & OV0456;o2) is an important measurement that helps guide the care of critically ill patients. Invasive S & OV0456;o2 assessment in infants and children is often avoided because of the inherent risks. A noninvasive tissue saturation (S to 2) monitor has recently been developed that uses near-infrared spectroscopy to measure oxyhemoglobin saturation in muscle. In adult and animal studies, S to 2 correlated with oxygen delivery and S & OV0456;o2. There has been no evaluation in pediatric patients. OBJECTIVE: To evaluate tissue saturation as a noninvasive measure of mixed venous saturation in children. DESIGN: A prospective observational study. SETTING: Catheterization laboratory in a tertiary care children's medical center. PATIENTS: We studied 98 children (49 without intracardiac mixing and 49 with intracardiac mixing) <or=12 yrs of age who underwent cardiac catheterization. Under general anesthesia, we compared S to 2 measured over the deltoid muscle with superior vena cava saturation in both groups and S to 2 with pulmonary artery saturation in patients without intracardiac mixing. Paired measurements were analyzed for bias, precision, and correlation via Bland-Altman plot and linear regression. RESULTS: No meaningful correlation was found between S to 2 and superior vena cava saturation or pulmonary artery saturation. Bland-Altman analyses of S to 2 with superior vena cava saturation yielded bias values of -6.67 +/- 37.33% in patients with intracardiac mixing and -0.82 +/- 41.31% in patients without mixing. Bland-Altman analysis of S to 2 with pulmonary artery saturation yielded a bias of 3.61 +/- 41.32% in patients without mixing. Differences between noninvasive and invasive measurements were greatest in smaller children. CONCLUSION: Noninvasive tissue saturation over the deltoid does not correlate with S & OV0456;o2 in children. It is possible that more precise probe spacing, coupled with optimal muscle-mass location, could result in more accurate measures in future investigations.

Cardiac Catheterization↗

Transcatheter device closure of congenital and postoperative residual ventricular septal defects.

BACKGROUND: Our purpose was to describe a 13-year experience with patients undergoing transcatheter device closure of unrepaired congenital or postoperative residual ventricular septal defects (VSDs). METHODS AND RESULTS: Since 1989, 170 patients (median age, 3.9 years) have undergone catheterization for closure of 1 or more congenital (n=92) or postoperative (n=78) residual VSDs using successive generations of STARFlex-type devices. Outcomes included echocardiographic assessment of residual flow and device position, assessment of VSD shunt/severity, and adverse events. Among 168 patients in whom device implantation was performed, between 1 and 7 devices were placed per patient (median, 1), with multiple devices placed in 40%. There was a significant decrease in left-to-right shunting after device implantation (P<0.001) and significant improvement in VSD size/severity, and device position proved stable. Of 332 adverse events, 39 were related to the device and 261 were related to the catheterization; all but 5 occurred in the periprocedural period. At a median follow-up of 24 months (0 to 154 months), 14 patients had died and 18 had device(s) explanted. CONCLUSIONS: Congenital and postoperative VSD closure using STARFlex-type devices resulted in stable improvement in clinical status and decreased interventricular shunting. Although periprocedural events occurred frequently, late events caused by the device were rare. Transcatheter device closure is an effective management option for patients with complex muscular VSDs that are difficult to approach surgically and for postoperative residual VSDs.

Cardiac Catheterization↗

Diagnostic assessment before Fontan operation in patients with bidirectional cavopulmonary anastomosis: are noninvasive methods sufficient?

OBJECTIVES: This study was designed to determine if a subset of patients who have undergone bidirectional cavopulmonary anastomosis could be identified in which catheterization was of little benefit before completion of the Fontan procedure. BACKGROUND: Diagnostic evaluation before Fontan procedure has typically included cardiac catheterization. However, the overall management strategy for patients with functional single ventricle has evolved to include staging bidirectional cavopulmonary anastomosis in most, and it has become uncommon to exclude patients from Fontan based on catheterization data. METHODS: Patients who underwent bidirectional cavopulmonary anastomosis and had complete echocardiograms and catheterizations within three months of each other between January 1992 and October 1997 were evaluated with a series of clinical and echocardiographic characteristics to identify a subset in whom catheterization was predicted to be of little added value ("no-cath" group). The predictive value and sensitivity of these criteria in excluding patients who required additional intervention, were excluded from Fontan, or died within 30 days of Fontan was determined. RESULTS: A total of 99 patients who underwent bidirectional cavopulmonary anastomosis at 6.7 months (range 2.9 months to 14 years) were studied; 46 met criteria for the "no-cath" group. Noninvasive criteria stratified all patients who died (n = 5) or did not proceed to Fontan (n = 1) and 9 of 11 who required additional interventions to the "cath" group. Thus, the negative predictive value of these criteria was 93%. CONCLUSIONS: Our data suggest that catheterization before Fontan could be avoided in a large percentage of patients without adversely affecting outcome; prospective evaluation of this strategy is warranted.

Adolescent↗

An evaluation of a noninvasive cardiac output measurement using partial carbon dioxide rebreathing in children.

Cardiac output (CO) is an important hemodynamic measure that helps to guide the therapy of critically ill patients. Invasive CO assessment in infants and children is often avoided because of the inherent risks. A noninvasive CO monitor that uses partial rebreathing has been recently developed to determine CO via the Fick principle for carbon dioxide. There have been no clinical studies confirming its accuracy in pediatric patients. This is a prospective observational study of 37 children <12 yr of age who underwent cardiac catheterization. Under general anesthesia via an endotracheal tube without a leak, we made multiple CO measurements using thermodilution and compared them with noninvasively determined CO measurements. Paired measurements were analyzed for bias, precision, and correlation via Bland-Altman plot and linear regression. Noninvasive measurements showed a linear correlation with thermodilution CO assessment with an r value of 0.83 (P < 0.03). Bland-Altman analysis yielded a bias of -0.27 L/min and a precision +/-1.49 L/min. Cardiac index measurements demonstrated a decreased r value of 0.67 (P = 0.15) and a bias of -0.18 L . min(-1) . m(-2) and precision of +/-2.13 L . min(-1) . m(-2). Differences between partial rebreathing measurements and thermodilution measurements were largest in children with a body surface area of </=0.6 m(2) ventilated with tidal volumes <300 mL. Based on these findings, noninvasive CO measurement using partial rebreathing may be clinically acceptable in children with >0.6 m(2) body surface area and >300 mL tidal volume.

Anesthesia, General↗

Open-cell design stents in congenital heart disease: a comparison of IntraStent vs. Palmaz stents.

Slotted stainless Palmaz stents (PS) remain the most commonly used in congenital heart disease (CHD). Limitations of PS include rigidity, foreshortening, poor conformability on expansion, balloon rupture, and jailing of side branches. Recently, stents with open-cell design (IntraStent; IS) in appropriate sizes for CHD have been introduced. We reviewed our experience with the IS, comparing performance with the PS in a retrospective nonrandomized, uncontrolled observational study. Between May 1999 and March 2001, 34 IS (10-36 mm) and 34 PS (10-40 mm) were implanted in 57 patients (3 months to 25 years old; median, 3.24 years) in congenital or postoperative lesions. There was no statistically significant difference between the two groups in efficacy, % diameter increase (162% +/- 203% for IS vs. 153% +/- 177% for PS), and % gradient reduction (69% +/- 23% for IS vs. 80% +/- 27% for PS). Other aspects of stent performance differed significantly (P < 0.05): PS forshortened more (mean 18% for PS vs. 0% for IS) and were associated with balloon rupture (9/34 for PS vs. 0/34 for IS; P = 0.002), but had no evidence of intimal protrusion in between struts (0/34 for PS vs. 14/34 for IS; P < 0.001) and no recoil > 15% (0/34 for PS vs. 7/34 for IS; P = 0.006); IS conformed almost twice as well to vessel curvature (P = 0.003). Although these factors did not affect immediate procedural success, balloon rupture in two PS resulted in stent malpositions. Among IS, the origins of three covered side branches were accessed and balloon dilated up to 6 mm through the side of the stent. In conclusion, stents with open-cell design have some characteristics that seem beneficial for their use in CHD: they foreshorten less, are conformable, are less likely to cause balloon rupture, and can allow access to jailed branches. However, they have a higher incidence of significant percent recoil and protrusion of intimal tissue in between struts, which may impact long-term stent performance.

Adolescent↗

Platelet-endothelial cell adhesion molecule-1-directed immunotargeting to cardiopulmonary vasculature.

Therapeutic molecules conjugated with antibodies to the platelet-endothelial cell adhesion molecule-1 (PECAM-1) accumulate in the pulmonary endothelium after i.v. injection in mice. In this study, we characterized PECAM-directed targeting to the lung and heart after local versus systemic intravascular administration in a large animal model, pigs. Radiolabel tracing showed that 1 h post-i.v. injection, 35% of anti-PECAM versus 2.5% of control IgG had accumulated in the lungs. Infusion of anti-PECAM via a catheter placed in the right pulmonary artery (RPA) resulted in a 3-fold elevation of the uptake in the right lower lobe and 2-fold reduction of uptake in the left lobes in the lung. Cardiac uptake of anti-PECAM was negligible after i.v. and RPA infusion. In contrast, delivery with a catheter placed in the right coronary artery (RCA) resulted in a 4-fold elevation of cardiac uptake of anti-PECAM, but not IgG, compared with i.v. injection. To estimate the targeting of an active reporter enzyme, streptavidin-conjugated beta-galactosidase (beta-Gal) was coupled to anti-PECAM or IgG (anti-PECAM/beta-Gal and IgG/beta-Gal) and injected into the RCA. Beta-Gal activity was markedly elevated in the heart and lungs (5- and 25-fold increased, respectively) after injection of anti-PECAM/beta-Gal, but not IgG/beta-Gal. Image analysis confirmed endothelial targeting of anti-PECAM/beta-Gal in the heart and lung. In summary, anti-PECAM antibody conjugates deliver agents to the pulmonary endothelium regardless of injection route, whereas local arterial infusion permits targeting to the cardiac vasculature. This paradigm may be useful for drug targeting to endothelium in lungs, heart, and possibly other organs.

Animals↗