Jonathan M Cannata

Publications and source records attributed to Jonathan M Cannata.

8 recordsLinked to original sources

Development of a 35-MHz piezo-composite ultrasound array for medical imaging.

This paper discusses the development of a 64-element 35-MHz composite ultrasonic array. This array was designed primarily for ocular imaging applications, and features 2-2 composite elements mechanically diced out of a fine-grain high-density Navy Type VI ceramic. Array elements were spaced at a 50-micron pitch, interconnected via a custom flexible circuit and matched to the 50-ohm system electronics via a 75-ohm transmission line coaxial cable. Elevation focusing was achieved using a cylindrically shaped epoxy lens. One functional 64-element array was fabricated and tested. Bandwidths averaging 55%, 23-dB insertion loss, and crosstalk less than -24 dB were measured. An image of a tungsten wire target phantom was acquired using a synthetic aperture reconstruction algorithm. The results from this imaging test demonstrate resolution exceeding 50 microm axially and 100 microm laterally.

Ceramics↗

Development of a real-time, high-frequency ultrasound digital beamformer for high-frequency linear array transducers.

A real-time digital beamformer for high-frequency (>20 MHz) linear ultrasonic arrays has been developed. The system can handle up to 64-element linear array transducers and excite 16 channels and receive simultaneously at 100 MHz sampling frequency with 8-bit precision. Radio frequency (RF) signals are digitized, delayed, and summed through a real-time digital beamformer, which is implemented using a field programmable gate array (FPGA). Using fractional delay filters, fine delays as small as 2 ns can be implemented. A frame rate of 30 frames per second is achieved. Wire phantom (20 microm tungsten) images were obtained and -6 dB axial and lateral widths were measured. The results showed that, using a 30 MHz, 48-element array with a pitch of 100 microm produced a -6 dB width of 68 microm in the axial and 370 microm in the lateral direction at 6.4 mm range. Images from an excised rabbit eye sample also were acquired, and fine anatomical structures, such as the cornea and lens, were resolved.

Computer Systems↗

Development of a high-frequency (> 50 mhz) copolymer annular-array, ultrasound transducer.

The development of a high frequency (> 50 MHz) annular array ultrasonic transducer is presented. The array was constructed by bonding a 9 microm P(VDF-TrFE) film to a two-sided polyimide flexible circuit with annuli electrodes on the top layer. Each annulus was separated by a 30 microm kerf and had several electroplated microvias that connected to electrode traces on the bottom side of the flex circuit. In order to improve device sensitivity, each element was electrically matched to an impedance magnitude of 50 omega and 0 degrees phase at resonance using a serial inductor and high impedance coaxial cable. The array's performance was evaluated by measuring the electrical impedance, pulse echo response, and cross talk between elements. The average round trip insertion loss was -33.5 dB after compensating for diffractive and attenuative losses. The measured average center frequency and bandwidth for an element was 55 MHz and 47%, respectively. The measured cross talk between adjacent elements remained below -29 dB at the center frequency in water. A vertical wire phantom was imaged using a single focus transmit beamformer and dynamic focusing receive beamformer. This image showed a significant improvement in lateral resolution over a range of 9 mm after the dynamic focusing receive algorithm was applied. These results correlated well with predictions from a Field II simulation. After beamforming, the minimum lateral resolution achieved by the array (-6 dB) was 108 microm at the focus.

Journal Article↗

Half-thickness inversion layer high-frequency ultrasonic transducers using LiNbO3 single crystal.

Half-thickness inversion layer high-frequency ultrasonic transducers were fabricated using lithium niobate (LiNbO3) single crystal plate. The transducers developed for this study used a 36 degrees rotated Y-cut LiNbO3 thin plate with an active element thickness of 115 microm. The designed center frequency was in the range of 30 to 60 MHz. Half-thickness inversion layer was formed after the sample was annealed at a high temperature, and it is shown that the inversion layer thickness can be controlled by the temperature. Silver powder/epoxy composite and parylene were used as acoustic matching layers. A lossy silver epoxy was used as the backing material. Using an analytical method, the electrical impedance for different inversion layer ratios was determined. The measured resonant frequency was consistent with the modeled data. Even-order higher frequency broadband ultrasonic transducers with a center frequency at 60 MHz was obtained using half-thickness inversion layer of LiNbO3 single crystal.

Journal Article↗

Fabrication and characterization of micromachined high-frequency tonpilz transducers derived by PZT thick films.

Miniaturized tonpilz transducers are potentially useful for ultrasonic imaging in the 10 to 100 MHz frequency range due to their higher efficiency and output capabilities. In this work, 4 to 10-microm thick piezoelectric thin films were used as the active element in the construction of miniaturized tonpilz structures. The tonpilz stack consisted of silver/lead zirconate titanate (PZT)/lanthanum nickelate (LaNiO3)/silicon on insulator (SOI) substrates. First, conductive LaNiO3 thin films, approximately 300 nm in thickness, were grown on SOI substrates by a metalorganic decomposition (MOD) method. The room temperature resistivity of the LaNiO3 was 6.5 x 10(-6) omega x m. Randomly oriented PZT (52/48) films up to 7-microm thick were then deposited using a sol-gel process on the LaNiO3-coated SOI substrates. The PZT films with LaNiO3 bottom electrodes showed good dielectric and ferroelectric properties. The relative dielectric permittivity (at 1 kHz) was about 1030. The remanent polarization of PZT films was larger than 26 microC/cm2. The effective transverse piezoelectric e31,f coefficient of PZT thick films was about -6.5 C/m2 when poled at -75 kV/cm for 15 minutes at room temperature. Enhanced piezoelectric properties were obtained on poling the PZT films at higher temperatures. A silver layer about 40-microm thick was prepared by silver powder dispersed in epoxy and deposited onto the PZT film to form the tail mass of the tonpilz structure. The top layers of this wafer were subsequently diced with a saw, and the structure was bonded to a second wafer. The original silicon carrier wafer was polished and etched using a Xenon difluoride (XeF2) etching system. The resulting structures showed good piezoelectric activity. This process flow should enable integration of the piezoelectric elements with drive/receive electronics.

Journal Article↗

Design and fabrication of broadband graded ultrasonic transducers with rectangular kerfs.

Broadband ultrasound imaging is capable of achieving superior resolution in clinical applications. An effective and easy way of manufacturing broadband transducers is desired for these applications. In this work, a graded material in which the piezoelectric plate is mechanically graded with rectangular grooves is introduced. Finite element analysis (FEA) demonstrated that the graded piezoelectric material could achieve a broadband, time-domain response resulting from multiple resonant modes. Experimental tests were carried out to validate these theoretical results. Based upon the FEA designs, several single-element transducers were fabricated using either a nondiced ceramic or a diced, graded ceramics. A superior bandwidth of 92% was achieved by the graded transducer when compared to a bandwidth of 56% produced by the nondiced ceramic transducer at the expense of a reduced sensitivity.

Ceramics↗

Design of efficient, broadband single-element (20-80 MHz) ultrasonic transducers for medical imaging applications.

This paper discusses the design, fabrication, and testing of sensitive broadband lithium niobate (LiNbO3) single-element ultrasonic transducers in the 20-80 MHz frequency range. Transducers of varying dimensions were built for an f# range of 2.0-3.1. The desired focal depths were achieved by either casting an acoustic lens on the transducer face or press-focusing the piezoelectric into a spherical curvature. For designs that required electrical impedance matching, a low impedance transmission line coaxial cable was used. All transducers were tested in a pulse-echo arrangement, whereby the center frequency, bandwidth, insertion loss, and focal depth were measured. Several transducers were fabricated with center frequencies in the 20-80 MHz range with the measured -6 dB bandwidths and two-way insertion loss values ranging from 57 to 74% and 9.6 to 21.3 dB, respectively. Both transducer focusing techniques proved successful in producing highly sensitive, high-frequency, single-element, ultrasonic-imaging transducers. In vivo and in vitro ultrasonic backscatter microscope (UBM) images of human eyes were obtained with the 50 MHz transducers. The high sensitivity of these devices could possibly allow for an increase in depth of penetration, higher image signal-to-noise ratio (SNR), and improved image contrast at high frequencies when compared to previously reported results.

Computer-Aided Design↗

Design, fabrication, and evaluation of high frequency, single-element transducers incorporating different materials.

The performance of high frequency, single-element transducers depends greatly on the mechanical and electrical properties of the piezoelectric materials used. This study compares the design and performance of transducers incorporating different materials. The materials investigated include 1-3 lead zirconate titanate (PZT) fiber composite, lead titanate (PbTiO3) ceramic, poly(vinylidene fluoride) (PVDF) film, and lithium niobate (LiNbO3) single crystal. All transducers were constructed with a 3-mm aperture size and an f-number between 2 and 3. Backing and matching materials were selected based on design goals and fabrication limitations. A simplified coaxial cable tuning method was employed to match the transducer impedance to 50 ohms for the PZT fiber composite and PbTiO3 ceramic transducers. Transducers were tested for two-way loss and -6 dB bandwidth using the pulse/echo response from a flat quartz target. Two-way loss varied from 21 to 46 dB, and bandwidths measured were in the range from 47 to 118%. In vitro ultrasonic backscatter microscope (UBM) images of an excised human eye were obtained for each device and used to compare imaging performance. Both press-focusing and application of a lens proved to be useful beam focusing methods for high frequency. Under equal gain schemes, the LiNbO3 and PbTiO3 transducers provided better image contrast than the other materials.

Equipment Design↗