PubMed Health⌕ Search

Biomedical subjects

Jonathan M Cooper

Publications and source records attributed to Jonathan M Cooper.

16 recordsLinked to original sources

Metabolic monitoring of the electrically stimulated single heart cell within a microfluidic platform.

A device based on five individually addressable microelectrodes, fully integrated within a microfluidic system, has been fabricated to enable the real-time measurement of ionic and metabolic fluxes from electrically active, beating single heart cells. The electrode array comprised one pair of pacing microelectrodes, used for field-stimulation of the cell, and three other microelectrodes, configured as an electrochemical lactate microbiosensor, that were used to measure the amounts of lactate produced by the heart cell. The device also allowed simultaneous in-situ microscopy, enabling optical measurements of cell contractility and fluorescence measurements of extracellular pH and cellular Ca2+. Initial experiments aimed to create a metabolic profile of the beating heart cell, and results show well defined excitation-contraction (EC) coupling at different rates. Ca2+ transients and extracellular pH measurements were obtained from continually paced single myocytes, both as a function of the rate of cell contraction. Finally, the relative amounts of intra- and extra-cellular lactate produced during field stimulation were determined, using cell electroporation where necessary.

Aerobiosis↗

Nanofabrication of electrode arrays by electron-beam and nanoimprint lithographies.

The fabrication of ordered nanoelectrode arrays using both electron-beam lithography and nanoimprint lithography is described. Arrays of nanoelectrodes with varying individual electrode diameters were produced and characterised electrochemically. Whilst both methods are highly reproducibile, nanoimprint lithography has the potential to produce devices rapidly and at low-cost. To our knowledge, this is the first report where nanoimprint lithography is employed for the production of nanoelectrode arrays for electroanalytical sensors.

Journal Article↗

Construction and characterization of a gold nanoparticle wire assembled using Mg2+-dependent RNA-RNA interactions.

Magnesium-ion-mediated RNA-RNA loop-receptor interactions, in conjunction with gold nanoparticles derivatized with DNA, have been used to make self-assembled nanowires. A wire located between lithographically fabricated nanoelectrodes is demonstrated that exhibits activated conduction by electron hopping at temperatures in the 150-300 K range. These techniques have the ability to link particles between devices and in the future may be used to assemble practical circuits.

Base Sequence↗

Posterolateral corner injuries of the knee: anatomy, diagnosis, and treatment.

Injuries to the posterolateral corner of the knee continue to be a complex problem for orthopedic surgeons. Early recognition and treatment are important factors in the patient's long-term outcome. To properly treat these patients, the surgeon must have a clear understanding of the anatomic relationships amongst the structures in the posterolateral knee. This knowledge combined with a thorough physical examination and imaging studies, allows the surgeon to make the correct diagnosis and devise an appropriate treatment plan. This article will discuss the anatomy, diagnosis, and treatment options to improve the surgeon's understanding of posterolateral knee injuries. The senior author's technique for anatomic reconstruction of the posterolateral corner of the knee and the rehabilitation protocol are described.

Humans↗

Stimulation of isolated ventricular myocytes within an open architecture microarray.

This paper is concerned with the physiological responses of single heart cells within microfluidic chambers, in response to stimulation by integrated microelectrodes. To enable these investigations, which included the measurement of action potential duration, intracellular Ca2+ and cell shortening, a series of microfluidic chambers (50 microm wide, 180 microm long, 400 microm high, 500 microm pitch) and connecting channels (200 microm wide, 5000 microm long, 50 microm high, 500 microm pitch) were replica-moulded into the silicone elastomer, polydimethylsiloxane (PDMS). The structures were formed against a master of posts and lines, photolithograhically patterned into the high aspect ratio photoresist SU-8. The chambers within the slab of PDMS were aligned against pairs of stimulating gold microelectrodes (50 microm long, 20 microm wide, 0.1-10 microm thick, 180 microm apart) patterned on a microscope coverslip base, thus defining cavities of approximately 4 nL volume. The assembly was filled with physiological saline and single isolated rabbit ventricular myocytes were introduced by micropipetting, thus creating limited volumes of saline above individual myocytes that could be varied between 4 nL and > or = 4 microL. The application of transient current pulses to the cells via the electrodes caused transient contractions with constant amplitude (recorded as changes in sarcomere length), confirming that excitation contraction coupling (EC coupling) remained functional in these limited volumes. Continuous monitoring of the intracellular Ca2+ (using calcium sensitive dyes) showed, that in the absence of bath perfusion, the amplitude of the transients remained constant for approximately 3 min in the 4-nL volume and approximately 20 min for the 4 microL volume. Beyond this time, the cells became unexcitable until the bath was renewed. The action potential duration (APD) was recorded at stimulation frequencies of 1 Hz and 0.5 Hz using potential sensitive dyes and was prolonged at the higher pacing rate. These studies show the prolonged electrical stimulation of isolated adult cardiac myocytes in microchambers with unimpaired EC coupling as verified on optical records of the action potential, Ca2+ transients and cell shortening. The open architecture provided free (pipetting) access for drug dispensation without cross talk between neighboring microwells, and multiplexed optical detection can be realized to study EC coupling on arrays of cells under both control and experimental conditions.

Action Potentials↗

A programmable microsystem using system-on-chip for real-time biotelemetry.

A telemetry microsystem, including multiple sensors, integrated instrumentation and a wireless interface has been implemented. We have employed a methodology akin to that for System-on-Chip microelectronics to design an integrated circuit instrument containing several "intellectual property" blocks that will enable convenient reuse of modules in future projects. The present system was optimized for low-power and included mixed-signal sensor circuits, a programmable digital system, a feedback clock control loop and RF circuits integrated on a 5 mm x 5 mm silicon chip using a 0.6 microm, 3.3 V CMOS process. Undesirable signal coupling between circuit components has been investigated and current injection into sensitive instrumentation nodes was minimized by careful floor-planning. The chip, the sensors, a magnetic induction-based transmitter and two silver oxide cells were packaged into a 36 mm x 12 mm capsule format. A base station was built in order to retrieve the data from the microsystem in real-time. The base station was designed to be adaptive and timing tolerant since the microsystem design was simplified to reduce power consumption and size. The telemetry system was found to have a packet error rate of 10(-3) using an asynchronous simplex link. Trials in animal carcasses were carried out to show that the transmitter was as effective as a conventional RF device whilst consuming less power.

Computer Systems↗

Dynamic in situ electrochemical neutron reflectivity measurements.

We report the first dynamic in situ electrochemical neutron reflectivity (NR) measurements on electroactive films. By using a boxcar integration strategy within a cyclic voltammetric experiment, it is possible to acquire neutron reflectivity data associated with narrow, defined windows of potential. Accumulation of data from repetitive cycles allows one to build up potential- (time-) resolved profiles. The effective time resolution is now on the order of seconds, as compared to ca. 1 h using conventional methodology, making in situ NR a practical technique for dynamic electrochemical studies. Illustrative data for polyvinylferrocene films reveal hysteresis in (de)swelling, incomplete desolvation upon reduction, and transient salt retention, all of which respond to time-scale variations.

Journal Article↗

Implementation of multichannel sensors for remote biomedical measurements in a microsystems format.

A novel microelectronic "pill" has been developed for in situ studies of the gastro-intestinal tract, combining microsensors and integrated circuits with system-level integration technology. The measurement parameters include real-time remote recording of temperature, pH, conductivity, and dissolved oxygen. The unit comprises an outer biocompatible capsule encasing four microsensors, a control chip, a discrete component radio transmitter, and two silver oxide cells (the latter providing an operating time of 40 h at the rated power consumption of 12.1 mW). The sensors were fabricated on two separate silicon chips located at the front end of the capsule. The robust nature of the pill makes it adaptable for use in a variety of environments related to biomedical and industrial applications.

Biomedical Engineering↗

Design and fabrication of a silica on silicon integrated optical biochip as a fluorescence microarray platform.

Previous research into the use of Flame Hydrolysis Deposition (FHD) of glasses in integrated optics has focused on the successful commercial exploitation of low cost optical devices within the field of telecommunications and optoelectronics. Recently we have sought to apply these fabrication technologies to the development of optical biochips, utilising their ability to be integrated with microfluidics as a 'Lab-on-a-chip' platform. In this paper, we carry this development forward by seeking to create a microarray of integrated optical sensing elements, addressed using a glass-polymer hybrid technology in which poly(dimethylsiloxane), PDMS, is used as an elastomeric packaging over-layer. In particular, we describe the wide range of modelling and microfabrication processes required for the successful manufacture, integration and packaging of such arrays. The integration of both optical and fluidic circuits in this device avoids precise alignment requirements and results in a compact, robust and reliable device. Finally, in this paper, we describe the implementation of a pumping system for delivering small amounts of fluid across the array together with an optical signal treatment.

Carbocyanines↗

Optimization of the geometry and porosity of microelectrode arrays for sensor design.

This paper describes the systematic investigation of a range of microelectrode arrays with varying dimensions fabricated by standard photolithographic and reactive-ion etching techniques. As expected from theory, the electrochemical behavior of microelectrode arrays with a constant individual diameter varied strongly with center-to-center spacing, the larger the spacing the more sigmoidal the recorded voltammogram. Furthermore, the behavior of arrays with a constant relative center-to-center spacing is shown to vary with individual electrode diameter, the arrays with the smallest electrodes producing strongly peaked voltammograms. Peak current densities and signal-to-noise ratios were also obtained for a variety of array geometries, and the use of electrodeposited platinum black electrodes was investigated. To demonstrate one advantage of using a loosely packed microelectrode array in electroanalysis, a ferrocene-mediated enzyme-linked assay involving the biocatalytic reduction of H2O2 was investigated. Results showed an improved temporal response, with current-time transients reaching a steady-state response more quickly using arrays with increased center-center spacings.

Biosensing Techniques↗

Electroanalysis of metabolic flux from single cells in simple picoliter-volume microsystems.

A picoliter-volume electrochemical analytical chamber has been developed for detecting the metabolic flux resulting from the stress responses of a single plant cell. Electrochemical cells, with volumes as small as 100 pL, were fabricated by controlled electrochemical dissolution of a gold wire sealed in glass (the back-etching of the metal realizing an ultralow-volume titer chamber). In the first instance, the electrode contained within the chamber was characterized by the microinjection of standard aliquots of either ascorbic acid or hydrogen peroxide. In all cases, experimental currents obtained correlated well with theoretical calculations. Subsequently, single plant cells were micromanipulated into the chambers and were exposed to amounts of the detergent SDS (which permeabilized the cell membrane and released the intracellular contents). The flux of metabolite released from a single cell was estimated by using electrochemical-linked assays based upon the enzymes catalase, ascorbate oxidase, and horseradish peroxidase (in each case), in the presence of a mediator. In so doing, we investigated the activity of the cellular protection mechanisms through the determination of peroxides, while the individual cell was "stressed". The technique was found to provide a reliable and reproducible method for making single-cell measurements, using fabrication procedures that are both simple and do not require photolithographic methods.

Journal Article↗

Micromachined nanocalorimetric sensor for ultra-low-volume cell-based assays.

Current strategies for cell-based screening generally focus on the development of highly specific assays, which require an understanding of the nature of the signaling molecules and cellular pathways involved. In contrast, changes in temperature of cells provides a measure of altered cellular metabolism that is not stimulus specific and hence could have widespread applications in cell-based screening of receptor agonists and antagonists, as well as in the assessment of toxicity of new lead compounds. Consequently, we have developed a micromachined nanocalorimetric biological sensor using a small number of isolated living cells integrated within a subnanoliter format, which is capable of detecting 13 nW of generated power from the cells, upon exposure to a chemical or pharmaceutical stimulus. The sensor comprises a 10-junction gold and nickel thermopile, integrated on a silicon chip which was back-etched to span a 800-nm-thick membrane of silicon nitride. The thin-film membrane, which supported the sensing junctions of the thermoelectric transducer, gave the system a temperature resolution of 0.125 mK, a low heat capacity of 1.2 nJ mK(-1), and a rapid (unfiltered) response time of 12 ms. The application of the system in ultra-low-volume cell-based assays could provide a rapid endogenous screen. It offers important additional advantages over existing methods in that it is generic in nature, it does not require the use of recombinant cell lines or of detailed assay development, and finally, it can enable the use of primary cell lines or tissue biopsies.

Adipocytes↗

SERRS. In situ substrate formation and improved detection using microfluidics.

Surface-enhanced resonance Raman scattering (SERRS) of a model derivative of TNT was detected using a microflow cell designed within the framework of the lab-on-a-chip concept, using only the analyte and readily available reagents. The SERRS substrate, silver colloid, was prepared in situ, on-chip, by borohydride reduction of silver nitrate. The silver colloid was imaged within the chip using a white light microscope in either transmission or, due to the high reflectivity of the colloid, reflection mode. A fine stream of colloid approximately 30 microm in width was formed in a 250-microm-wide channel at the point where the colloid preparation reagents met. The chip was designed to produce a concentrated stream of colloid within a laminar regime, such that particles did not readily disperse into the fluid. One result of this was to reduce the effective volume of analysis. Attempts to deliberately disrupt this stream with microstructured pillars, fabricated in the fluidic channels, were unsuccessful. The chip was also designed to have the appropriate dimensions for detection using a modern Raman microscope system, which collects scattering from a very small volume. A dye derived from TNT was used as a model analyte. Quantitative behavior was obtained over 4 orders of magnitude with a detection limit of 10 fmol. This performance is between 1 and 2 orders of magnitude better than that achieved using a macroflow SERRS cell. The technique has the added advantage that both reagent consumption and effluent production are greatly reduced, leading to reduced operating costs and a decreased environmental impact

Journal Article↗

Ultra-low-volume, real-time measurements of lactate from the single heart cell using microsystems technology.

The fabrication of microelectrodes integrated within ultra-low-volume microtiter chambers for the amperometric determination of metabolites continues to be of interest in the subject of single-cell and high-throughput screening. The microsystem described in this paper consists of a two-microelectrode sensor with a microfluidic dispensation technology, which is able to deliver both very low titers (6.5 pL) and single heart cells into a low-volume microphotoelectrochemical cell. Devices were fabricated using photolithography and liftoff giving reproducible sensors integrated within high aspect ratio titer chambers (with a volume of 360 pL), made of the photoepoxy SU8. In this paper, the determination of lactate was optimized using an enzyme-linked assay based upon lactate oxidase, involving the amperometric determination of hydrogen peroxide at +640 mV versus an internal Ag/AgCl pseudoreference. The microsystem (including the microfluidic dispensers and structures as well as the microsensor) was subsequently used to measure the lactate content of single heart cells. Dynamic electrochemical measurements of lactate during cell permeabilization are presented. We also show the use of respiratory uncouplers to simulate ischemia in the single myocyte and show that, as expected, the rate of lactate production from the hypoxic heart cell is greater than that within the normoxic healthy myocyte.

Indicators and Reagents↗