Differences in the compressive stress-strain response of infiltrating ductal carcinomas with and without lobular features--implications for mammography and elastography.

In a previous study, it was noted that in some cases when compressive strains greater than about 5% were applied to tumors removed from the breast, there was an abrupt and irreversible change in the tissue stiffness. The data from that study were further analyzed and infiltrating ductal carcinomas with and without lobular features were selected for additional testing to explore their behavior under compressive strains from 0-10%. Fresh tumor samples were tested using a servo-hydraulic Instron testing machine to apply ramp type displacement loads to the samples. The results show that when strains greater than 5% are applied to the tumor tissue without lobular features, there is an irreversible decrease in the stiffness of the tissue while no such change is noted in the other tumor tissue. The implications for this behavior in making mammographic and elastographic images of the breast were then explored using finite element simulations to determine under what compression conditions could the critical strain threshold be reached in the tumor tissue.

Breast Neoplasms↗

Ultrasonic elastography using sector scan imaging and a radial compression.

Elastography is an imaging technique based on strain estimation in soft tissues under quasi-static compression. The stress is usually created by a compression plate, and the target is imaged by an ultrasonic linear array. This configuration is used for breast elastography, and has been investigated both theoretically and experimentally. Phenomena such as strain decay with tissue depth and strain concentrations have been reported. However in some in vivo situations, like prostate or blood vessels imaging, this set-up cannot be used. We propose a device to acquire in vivo elastograms of the prostate. The compression is applied by inflating a balloon that covers a transrectal sector probe. The 1D algorithm used to calculate the radial strain fails if the center of the imaging probe does not correspond to the center of the compressor. Therefore, experimental elastograms are calculated with a 2D algorithm that accounts for tangential displacements of the tissue. In this article, in order to gain a better understanding of the image formation process, the use of ultrasonic sector scans to image the radial compression of a target is investigated. Elastograms of homogeneous phantoms are presented, and compared with simulated images. Both show a strain decay with tissue depth. Then experimental and simulated elastograms of a phantom that contains a hard inclusion are presented, showing that strain concentrations occur as well. A method to compensate for strain decay and therefore to increase the contrast of the strain elastograms is proposed. It is expected that such information will help to interpret and possibly improve the elastograms obtained via radial compression.

Algorithms↗

Axial resolution in elastography.

The limits and trade-offs of the axial resolution in elastography were investigated using a controlled simulation study. The axial resolution in elastography was estimated as the distance between the full widths at half-maximum of the strain profiles of two equally stiff lesions embedded in a softer homogeneous background. The results show that the upper bound of the axial resolution in elastography is controlled by the physical wave parameters of the ultrasound (US) system used to acquire the data (transducer center frequency and band- width). However, an inappropriate choice of the parameters used to process the US data (cross-correlation window length and shift between consecutive windows) may compromise the best resolution attainable. The measured elastographic axial resolution was found to be on the order of the ultrasonic wavelength.

Computer Simulation↗

Myocardial elastography--a feasibility study in vivo.

Early detection of cardiovascular diseases has been a very active research area in the medical imaging field. Assessment of the local and global mechanical functions is one of the major goals of accurate diagnosis. In this study, we investigated the feasibility of elastography for estimation and imaging of the local cardiac muscle displacement and strain in a human heart in vivo. In its noninvasive applications, elastography has been typically used to determine local tissue strain through the use of externally applied compression. For our study, we utilized the cardiac muscle motion during a cardiac cycle as the mechanical stimulus, and acquired successive radiofrequency (RF) data frames of the septal and posterior walls over a few cardiac cycles in parasternal and apical views, respectively. High-quality ciné-loop elastograms were obtained due to high frame rates and the resulting low decorrelation noise. Furthermore, the strain contrast was higher in the parasternal case, when only the posterior wall was imaged, and strain estimation was more robust in the apical view. High repeatability of the results was observed through elastographic measurements over several cardiac cycles. Finally, an M-mode version of elastography was used to follow part of the interventricular septum or the posterior wall over the course of two cardiac cycles. Not only do these preliminary results show that elastography is feasible in cardiac applications in vivo, but also that it can provide new information regarding cardiac motion and mechanical function. Future prospects include assessment of the role of elastography in detection of ischemia and infarction.

Adult↗

Variational method for estimating the effects of continuously varying lenses in HIFU, sonography, and sonography-based cross-correlation methods.

The effects of high intensity focused ultrasound (HIFU)-induced continuously varying thermal gradients on sound ray propagation were modeled theoretically. This modeling was based on Fermat's variational principle of least time for rays propagating in a continuously varying thermal gradient described by a radially symmetric heat equation. Such thermal lenses dynamically affect HIFU beam focusing, and simultaneously create ultrasonic geometric and intensity distortions and artifacts in monitoring devices. Techniques which are based upon ultrasonic cross-correlation methods, such as elastography and two-dimensional temperature estimation, also suffer distortion effects and generate artifacts.

Hearing↗