PubMed Health⌕ Search

Biomedical subjects

Jong Bum Son

Publications and source records attributed to Jong Bum Son.

2 recordsLinked to original sources

Fat-suppressed three-dimensional dual echo Dixon technique for contrast agent enhanced MRI.

PURPOSE: To develop a fast T1-weighted, fat-suppressed three-dimensional dual echo Dixon technique and to demonstrate its use in contrast agent enhanced MRI. MATERIALS AND METHODS: A product fast three-dimensional gradient echo pulse sequence was modified to acquire dual echoes after each RF excitation with water and fat signals in-phase (IP) and opposed-phase (OP), respectively. An on-line reconstruction algorithm was implemented to automatically generate separate water and fat images. The signal to noise ratio (SNR) of the new technique was compared to that of the product technique in phantom. In vivo abdomen and breast images of cancer patients were acquired at 1.5 Tesla using both techniques before and after intravenous administration of gadolinium contrast agent. RESULTS: In phantom, the new technique yields a close to the theoretically predicted 41% increase in SNR in comparison to the product technique without fat suppression (FS). In vivo images of the new technique show noticeably improved FS and image quality in comparison to the images acquired of the same patients using the product technique with FS. CONCLUSION: The three-dimensional dual echo Dixon technique provides excellent image quality and can be used for T1-weighted, fat-suppressed imaging with contrast agent injection.

Algorithms↗

A fast spin echo two-point Dixon technique and its combination with sensitivity encoding for efficient T2-weighted imaging.

A fast spin echo two-point Dixon (fast 2PD) technique was developed for efficient T2-weighted imaging with uniform water and fat separation. The technique acquires two interleaved fast spin echo images with water and fat in-phase and 180 degrees out-of-phase, respectively, and generates automatically separate water and fat images for each slice. The image reconstruction algorithm uses an improved and robust region-growing scheme for phase correction and achieves consistency in water and fat identification between different slices by exploiting the intrinsic correlation between the complex images from two neighboring slices. To further lower the acquisition time to that of a regular fast spin echo acquisition with a single signal average, we combined the fast 2PD technique with sensitivity encoding (SENSE). Phantom experiments show that the fast 2PD and SENSE are complementary in scan efficiency and signal-to-noise ratio (SNR). In vivo data from scanning of clinical patients demonstrate that T2-weighted imaging with uniform and consistent fat separation, including breath-hold abdominal examinations, can be readily performed with the fast 2PD technique or its combination with SENSE.

Abdomen↗